Page 301
I/O Parameters
Object Info Output Definition: Serial Cmd: Default: Options:
If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included. <K757,comm port,image mode,image format,jpeg quality,object info output> Disabled 0 = Disabled 1 = Enabled
Quadrus Verifier User’s Manual
8-61
Page 302
Configuring EZ Trax Output
8-62
Quadrus Verifier User’s Manual
Page 303
9 Matchcode Contents Matchcode by ESP ....................................................................................................................... 9-2 Matchcode Serial Commands ...................................................................................................... 9-3 Overview of Matchcode ................................................................................................................ 9-4 Matchcode Type ........................................................................................................................... 9-5 Sequential Matching ..................................................................................................................... 9-6 Match Start Position ..................................................................................................................... 9-7 Match Length................................................................................................................................ 9-8 Wild Card Character ..................................................................................................................... 9-9 Sequence On No Read .............................................................................................................. 9-10 Sequence On Mismatch ............................................................................................................. 9-11 Sequence Step .......................................................................................................................... 9-12 Match Replace............................................................................................................................ 9-13 Mismatch Replace ...................................................................................................................... 9-14 New Master Pin .......................................................................................................................... 9-15
This section explains the matchcode output functions and the master symbol database setup.
Quadrus Verifier User’s Manual
9-1
Page 304
Matchcode by ESP
Matchcode by ESP To open the entire contents of the tree control, hold down the Alt key and single-click the +. To close the entire contents of the tree control, hold down the Alt key and single-click the - . Click this button to bring up the Matchcode menu.
To open nested options, single-click the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
9-2
Quadrus Verifier User’s Manual
Page 305
Matchcode
Matchcode Serial Commands Matchcode Type
Sequence Step Match Replace Mismatch Replace New Master Pin Number of Master Symbols Enter Master Symbol Data Read Next Symbol as Master Symbol Request Master Symbol Data Delete Master Symbol Data
Quadrus Verifier User’s Manual
<K223,type,sequential matching,match start position,match length,wild card character, sequence on no read,sequence on mismatch> <K228,sequence step> <K735,status,replacement string> <K736,status,replacement string> <K225,status> <K224,number of master symbols> <K231,master symbol number,data> <Gmaster symbol number> <K231?,>[for all] or <K231?,master symbol number> <K231,master symbol number,>
9-3
Page 306
Overview of Matchcode
Overview of Matchcode Definition:
With Matchcode you can store master symbol data in the reader’s memory, compare this data against the read symbols, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be set up for up to 10 master symbols. Note: Matchcode will function with multiple symbols. However, if Matchcode Type is set to Sequential, or if Triggering Mode is set to Continuous Read 1 Output, Number of Symbols will default back to 1 (if set to any number greater than 1).
Usage:
Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.
Steps for Entering and Using Master Symbols 1. Set Triggering Mode to External or Serial. 2. Chose the method of symbol comparison that fits your application. 3. Define the output you want to achieve with your matchcode setup: a) Symbol data output. b) Discrete output. 4. Select the number of master symbols you want to create. 5. Decide which of 4 ways you want enter your master symbol(s): a) Use ESP to send master symbol data directly. b) Send a serial command with symbol data in the form of <M231,master symbol#, data>. c) Send a <G> (Read Next Symbol as Master Symbol) command. d) Enable the New Master Pin command and activate a discrete input to store the in the next symbol read as master symbol. 6. Enter master symbol data using the method determined in step 4.
9-4
Quadrus Verifier User’s Manual
Page 307
Matchcode
Matchcode Type Definition:
Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Triggering Mode to External or Serial.
ESP:
Serial Cmd:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on no read,sequence on mismatch>
Default:
Disabled
Options:
0 = Disabled 2 = Sequential
Disabled:
Has no effect on operations.
Enabled:
Instructs the reader to compare symbols or portions of symbols with the master symbol.
Sequential:
Instructs the reader to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers. Note: If Matchcode Type is set to Sequential, Number of Symbols will default back to 1 (if set to any number greater than 1).
Wild Card:
Allows the user to enter user defined wild card characters in the master symbol.
Quadrus Verifier User’s Manual
1 = Enabled 3 = Wild Card
9-5
Page 308
Sequential Matching
Sequential Matching Usage:
Useful in tracking product serial numbers that increment or decrement sequentially.
Definition:
With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on no read,sequence on mismatch>
Default:
Increment
Options:
0 = Increment
9-6
1 = Decrement
Quadrus Verifier User’s Manual
Page 309
Matchcode
Match Start Position Usage:
Match Start Position is useful in defining specific portions of a symbol for comparisons. For example, if a symbol contains a part number, manufacturing date, and lot code info but the user is only interested in the part number information. With Match Start Position the reader can be set to only sort on the part number and ignore the rest of the characters.
Definition:
Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential.
Function:
For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on no read,sequence on mismatch>
Default:
0
Options:
0 to 2710
Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
Quadrus Verifier User’s Manual
9-7
Page 310
Match Length
Match Length Usage:
For example, if Match Length is set to 6 in a 10 character symbol, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared.
Definition:
Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. when Match Start Position is set to 0, no comparison will occur.
Serial Cmd:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on no read,sequence on mismatch>
Default:
1
Options:
1 to 2710
9-8
Quadrus Verifier User’s Manual