Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 28 of 47

Quadrus Verifier User's Manual, pages 271 to 280

Pages 271 to 280 of 470

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan Verifier

Page 271

I/O Parameters

Load IP Database (EZ Button) Definition:

Allows the user to load the IP database with calibration results. When the user performs a calibration using the EZ button, all the database entries are moved down one index and the results of the calibration are saved to index 0. Note the results will saved as current settings as well.

Serial Cmd:

<K770,global status,default on power-on,load IP database,save for poweron>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Save for Power-On (EZ Button) Definition:

If enabled, after calibration is complete, all parameters will saved for power-on.

Serial Cmd:

<K770,global status,default on power-on,load ip database,save for poweron>

Default:

Disabled

Options:

0 = Disabled

Quadrus Verifier User’s Manual

1 = Enabled

8-31

Page 272

EZ Button Modes

EZ Button Modes Usage:

Useful for performing multiple, repetitive tasks at the work site.

Definition:

Allows user to program each of EZ button’s 4 positions from a selection of 8 modes.

Serial Cmd:

<K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode>

Options: Single Beep 0 = Disabled 1 = Read rate 2 = Calibrate 3 = Save for power on 4 = Unused 5 = Load new master 6 = Unused 7 = Target system 8 = Live Video 9 = Bar Code Config.

Two Beeps 0 = Disabled 1 = Read rate 2 = Calibrate 3 = Save for power on 4 = Unused 5 = Load new master 6 = Unused 7 = Target system 8 = Live Video 9 = Bar Code Config.

Three Beeps 0 = Disabled 1 = Read rate 2 = Calibrate 3 = Save for power on 4 = Unused 5 = Load new master 6 = Unused 7 = Target system 8 = Live Video 9 = Bar Code Config.

Four Beeps 0 = Disabled 1 = Read rate 2 = Calibrate 3 = Save for power on 4 = Unused 5 = Load new master 6 = Unused 7 = Target system 8 = Live Video 9 = Bar Code Config.

Disabled When set to disabled, the associated button position will have no function associated with it, and the position will be skipped over.

Read Rate Read rate will be initiated when the associated button position is selected. Read rate will perform decodes/second and is the same as sending a <C> from the terminal. To exit read rate mode quickly press and release the EZ button.

Calibrate Calibration will be initiated when the associated button position is selected. To abort calibration, quickly press and release the EZ button.

Save for Power On All reader settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending the <Z> in the terminal.

8-32

Quadrus Verifier User’s Manual

Page 273

I/O Parameters

Load New Master Functions the same as new master pin input whenever the associated button position is selected. The new master pin’s Consecutive Decode requirement holds true for this function.

Target System Turns on the targeting system (target pattern) whenever the associated button position is selected. To disable, quickly press and release the EZ button. Note: This mode is the only one that does not require that the button be released before taking effect. Thus, as soon as the Verifier beeps the appropriate number of times for the position, it will take effect. If it is necessary to have the target system on before another operation such as calibration or read rate is performed, ensure that the target system mode is assigned a lower position so that it will be activated first.

Live Video Enables live video mode when the associated button position is selected. To disable, quickly press and release the EZ button. Important: If the user has a non-video unit and this mode is selected, it will behave the same as if the mode was disabled.

Bar Code Configuration Enables bar code configuration mode whenever the associated button position is selected. When enabled, the reader can accept configuration commands from symbols. To disable, quickly press and release the EZ button.

EZ Button Operation To execute EZ button commands,

Single Beep (Position #1) Hold down button until a singe beep is heard (and the 20% LED illuminates).

Two Beeps (Position #2) Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate).

Three Beeps (Position #3) Hold down button until three quick beeps are heard (and the 20%, 40% and 60% LEDs illuminate).

Four Beeps (Position #4) Hold down button until four quick beeps are heard (and the 20%, 40%, 60% and 80% LEDs illuminate).

Quadrus Verifier User’s Manual

8-33

Page 274

Input 1

Input 1 Usage:

For example, an application is set up so that a mismatch stops the production line by using outputs in a latch mode. A push button switch can be connected to the input pin so that when pressed, it unlatches the output, allowing the line to resume operations.

Definition:

A programmable, discrete input used to reset counters, outputs or control optoelectrical settings.

Serial Cmd:

<K730,input mode,active state>

Default:

Disabled

Options:

0 = Disabled

1 = Reset Counts

2 = Unlatch Output

Disabled Definition:

When set to Disabled there is no effect on operation.

Reset Counts Usage:

Primarily used in test mode. Can also be used to reset counters daily.

Definition:

When set to Reset Counts, a transition to the active state of the input will cause the reader to reset the internal counters.

Unlatch Output Definition:

This setting is used in combination with any of the three discrete outputs that are in Unlatch Mode 1. A transition to the active state will clear any of the three outputs that were previously latched.

Active State (Input) Definition:

Sets the active level of the input pin.

Serial Cmd:

<K730,input mode,active state>

Default:

Active Off

Options:

0 = Active On (same as active closed) 1 = Active Off (same as active open)

8-34

Quadrus Verifier User’s Manual

Page 275

I/O Parameters

Output 1 Parameters

Usage:

This option provides switching to host software to control external devices such as PLCs and relays. It is useful for routing and sorting and to prevent mis-packaging and mis-routing.

Definition:

Sets the discrete output functions for specific user-selected conditions.

Output On (Output 1)

Definition:

Allows the user to set the conditions under which an output (or outputs) will be activated.

Serial Cmd:

<K810,output on,output state,pulse width,output mode>

Default:

Mismatch or No Read

Options:

0 = Mismatch Or No Read 2 = Mismatch 4 = Trend Analysis 6 = Diagnostic Warning

1 = Good Read/Match 3 = No Read 5 = Symbol Quality 7 = In Read Cycle

Note: If Output On is set to Mismatch Or No Read, Match, or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.

Quadrus Verifier User’s Manual

8-35

Page 276

Output 1 Parameters

Mismatch or No Read (Output On) Activates discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.

Good Read/Match (Output On) Activates a discrete output when the symbol data matches the master symbol. Note: If you want to output for a good read and Matchcode is not enabled, you can enable any output for Match.

Mismatch (Output On) Activates a discrete output when the symbol data does not match that of the master symbol.

No Read (Output On) Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.

Trend Analysis (Output On) Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.

Symbol Quality (Output On) Activates discrete output when a symbol quality condition is met, depending on the symbol quality option enabled.

Diagnostic Warning (Output On) Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.

In Read Cycle (Output On) Output is active while reader is operating in the read cycle.

8-36

Quadrus Verifier User’s Manual

Page 277

I/O Parameters

Output State (Output 1)

Definition:

Sets the active electrical state of the discrete output.

Serial Cmd:

<K810,output on,output state,pulse width,output mode>

Default:

Normally Open

Options:

0 = Normally Open

1 = Normally Closed

Pulse Width (Output 1)

Definition:

Sets the time in 10 ms increments that the discrete output remains active.

Serial Cmd:

<K810,output on,output state,pulse width,output mode>

Default:

5 (Corresponds to .05 seconds)

Options:

0 to 255 (0 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds.

Quadrus Verifier User’s Manual

8-37

Page 278

Output 1 Parameters

Output Mode (Output 1)

Definition:

Sets the condition in which the discrete output is de-activated.

Serial Cmd:

<K810,output on,output state,pulse width,output mode>

Default:

Pulse

Options:

0 = Pulse 1 = Latch Mode 1 (Unlatch Input # 1 Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)

Pulse This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.

Latch Mode 1 (Unlatch Input # 1 Pin) The programmable output is active when the Output On condition has been met and held active until the discrete Input 1 has been activated.

Latch Mode 2 (Unlatch Opposite Condition) The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if No Read is enabled under Output On, the programmable output will go active upon a No Read and remain active until the opposite condition, a good read, occurs.

Latch Mode 3 (Unlatch Re-Enter Read Cycle) The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins.

8-38

Quadrus Verifier User’s Manual

Page 279

I/O Parameters

Trend Analysis (Output 1) Note: Output On under Output 1 Parameters must be set to Trend Analysis for this output to function.

Usage:

Useful in cases in which the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions.

Definition:

Applies Trend Analysis settings to Output 1. With Trend Analysis, the user can track the occurrences and frequency of mismatches, No Reads, and the number of reads per trigger and output the results to any of three outputs.

Example:

Trend analysis mode = No Read Number of Triggers = 25 Number to Output On = 4 In this example, the reader would activate an output when 4 No Reads occured within a period of 25 triggers (read cycles).

Quadrus Verifier User’s Manual

8-39

Page 280

Output 1 Parameters

Trend Analysis Mode (Trend Analysis) Definition:

Sets the trend condition (Mismatch, No Read, or Reads/Trigger) that will activate the output.

Serial Cmd:

<K780,trend analysis mode,number of triggers,number to output on>

Default:

No Read

Options:

0 = Mismatch 3 = Bad Symbol

1 = No Read 4 = No Symbol

2 = Unused

Mismatch Output will be activated when the number of Mismatches equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

No Read Output will be activated when the number of No Reads equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

Bad Symbol Output will be activated when the number of Bad Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

No Symbol Output will be activated when the number of No Symbol occurrences equals the value entered for Number to Output On within the trigger window selected in Number of Triggers.

8-40

Quadrus Verifier User’s Manual