Page 241
8 I/0 Parameters Contents I/O Parameters by ESP.................................................................................................................8-2 I/O Parameters Serial Commands ................................................................................................8-3 Symbol Data Output......................................................................................................................8-4 When to Output Symbol Data .......................................................................................................8-6 No Read Message ........................................................................................................................8-7 Bad/No Symbol Qualification ........................................................................................................8-9 Read Duration Output .................................................................................................................8-16 Output Indicators.........................................................................................................................8-17 Serial Verification ........................................................................................................................8-20 Video Output ...............................................................................................................................8-22 Image Output ..............................................................................................................................8-24 Image Captioning ........................................................................................................................8-26 Synchronous Trigger...................................................................................................................8-28 EZ Button ....................................................................................................................................8-30 EZ Button Modes ........................................................................................................................8-32 Input 1 .........................................................................................................................................8-34 Output 1 Parameters...................................................................................................................8-35 Output 2 Parameters...................................................................................................................8-48 Output 3 Parameters...................................................................................................................8-52 Configuring EZ Trax Output ........................................................................................................8-56
This section includes instructions on setting up conditions for changing input/output electrical transitions for control of internal and external devices. A discrete I/O (in/out) signal is an electrical transition from one voltage level to another so that digital switching can occur.
Quadrus Verifier User’s Manual
8-1
Page 242
I/O Parameters by ESP
I/O Parameters by ESP To open the entire contents of the tree control, hold down the Alt key and single-click the +. To close the entire contents of the tree control, hold down the Alt key and single-click the - . Click this button to bring up the I/O Parameters menu.
To open nested options, single-click the +.
8-2
To change a setting, double-click the setting and use your cursor to scroll through the options.
Quadrus Verifier User’s Manual
Page 243
I/O Parameters
I/O Parameters Serial Commands Symbol Data Output
<K705,symbol data output status,when to output>
No Read Message
<K714,no read message status,no read message>
Bad Symbol Message
<K715,[unused],message>
No Symbol Message
<K716,[unused],message>
1D/Stacked Symbology Qualification
<K717,minimum number of bars,minimum number of qualified scans,start/ stop status>
2D Symbology Qualification
<K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Read Duration Output
<K706,status,separator>
LED Indicators
<K750,green flash mode,target pattern status,green flash duration>
Beeper
<K702,beeper status>
LED Configuration
<K737,LED mode,ISO/IEC 15415 grade,DPM grade>
Serial Verification
<K701,serial command echo status,serial command beep status,control/hex output>
Video Output
<K760,video output status,trigger image mode,image frame>
Image Output
<K739,image output status,com port,file format,JPEG quality>
EZ Trax Output
<K757,comm port,image mode,image format,jpeg quality,object info output>
Image Captioning
<K762,mode>
Synchronous Trigger
<K761,synchronous trigger mode>
EZ Button
<K770,global status,default on power-on,load IP database,save for power-on >
EZ Button Modes
<K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode>
Input 1
<K730,input mode,active state>
Output 1 Parameters
<K810,output on,active state,pulse width,output mode>
Trend Analysis Output 1
<K780,trend analysis mode,number of triggers,number to output on>
Diagnostic Warnings Output 1 ISO/IEC 15415 Verification Output 1
<K790,over temp,service unit,external camera disconnect> <K830,grade,decode,symbol contrast,fixed pattern damage,axial non-uniformity,grid non-uniformity,modulation,unused error correction,print growth value>
AS9132 Verification Output 1
<K840,dot center offset,cell fill, dot ovality,angle of distortion,symbol contrast, quiet zone>
Output 2 Parameters
<K811,output on,active state,pulse width,output mode>
Trend Analysis Output 2
<K781,trend analysis mode,trigger evaluation period,number to output on>
Diagnostic Warnings Output 2
<K791,over temp,service unit,external camera disconnect>
ISO/IEC 15415 Verification Output 2
<K831,grade,decode,symbol contrast,fixed pattern damage,axial non-uniformity,grid non-uniformity,modulation,unused error correction,print growth value>
AS9132 Verification Output 2
<K841,dot center offset,cell fill, dot ovality,angle of distortion,symbol contrast, quiet zone>
Note: The Quadrus Verifier does not have an Output 3 option by default. If your application requires an Output 3, contact your Microscan sales representative for more information.
Quadrus Verifier User’s Manual
8-3
Page 244
Symbol Data Output
Symbol Data Output Note: Symbol Data Output relates to data and should not to be confused with Outputs 1, 2, and 3 listed in the Outputs Parameters which describe output states and functions. Usage:
Useful when the host needs symbol data only under certain conditions.
Definition:
Defines the conditions under which decoded symbol data is transmitted to the host.
Serial Cmd:
<K705,symbol data output status,when to output>
Default:
Good Read
Options:
0 = Disabled 2 = Mismatch
1 = Match 3 = Good Read
Note: Symbol Data Output Status if set to Match or Mismatch will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.
Disabled Usage:
It is useful when an application only needs to use the discrete outputs and can allow the reader to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks.
Definition:
When set to Disabled, the reader will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.).
Match Usage:
Match is used in an application that requires specific symbol information and needs to sort, route or verify based on matching the specific symbol data.
Definition:
When set to Match, the reader transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A No Read can still be transmitted if Enabled.
Mismatch Usage:
Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.
Definition:
With Mismatch enabled, the reader transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A No Read can still be transmitted if enabled.
8-4
Quadrus Verifier User’s Manual
Page 245
I/O Parameters
Good Read Usage:
Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.
Definition:
With Good Read enabled, the reader transmits symbol data on any good read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if enabled.
Quadrus Verifier User’s Manual
8-5
Page 246
When to Output Symbol Data
When to Output Symbol Data Definition:
This command allows the user to choose when symbol data can be sent to the host.
Serial Cmd:
<K705,symbol data output status,when to output>
Default:
As Soon As Possible
Options:
0 = As Soon As Possible
1 = End of Read Cycle
As Soon As Possible Usage:
As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data.
Definition:
Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set.
End of Read Cycle Usage:
End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded.
Definition:
Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle
Start of read cycle Read cycle duration Host activates trigger
This is when host expects output
Read Cycle
8-6
Quadrus Verifier User’s Manual
Page 247
I/O Parameters
No Read Message Usage:
Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.
No Read Message Mode Serial Cmd:
<K714,no read message status,no read message>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
2 = Detailed No Read Message
Disabled No message is output when a No Read condition occurs.
Enabled The user-defined No Read message is output whenever a No Read condition occurs.
Detailed No Read Message Important: In the case where the conditions set in Bad/No Symbol Qualification are met, then the Bad Symbol or No Symbol message output will override the No Read Message or the Detailed No Read Message, if either is enabled. Usage:
Use this option to cover more detailed reasons for decode failures.
Definition:
Outputs a No Read message followed by an additional message (an Image Processing Results Code) indicating the reason a symbol failed to decode.
For example, in the following output: “No Read d_1, E_2” d and E are symbology ids for Datamatrix and UPC respectively. The message means that Datamatrix and UPC are enabled (and other symbologies are not), and that both failed to decode. The reason for the failing Datamatrix is 1 and the reason for the failing UPC is 2. The first part of these numbers (preceding the dot) is the relevant number and interpreted here:
2D Symbologies: 1. Failed to locate symbol (no finder pattern). 2. Failed to locate four corners or failed to qualify user-defined dimension (in pixels). 3. Failed to locate clocks or failed to qualify user-defined orientation (0-359 degree). 4. Failed to validate clocks or failed to qualify user-defined symbol size (clock element count). 5. Failed to decode symbol.
Quadrus Verifier User’s Manual
8-7
Page 248
No Read Message
Linear Symbologies: 1. Failed user-defined minimum number of bars. 2. Failed to decode start/stop character (doesn’t apply to UPC, RSS, MicropPDF417 and Pharmacode). 3. Failed user-defined minimum number of scan lines that qualify for the minimum number of bars. 4. Failed to decode. 5. Failed to decode UPC supplemental.
No Read Message Definition:
Any combination of ASCII characters can be defined as the No Read message.
Serial Cmd:
<K714,no read message status,no read message>
Default:
No Read
Options:
0 to 128 ASCII characters.
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch or Good Read. No Read Message can be set to any ASCII characters except NULL, < , or >.
8-8
Quadrus Verifier User’s Manual
Page 249
I/O Parameters
Bad Symbol/No Symbol Qualification Usage:
Useful in determining if a symbol is present and if user-defined requirements for that symbol are met.
Definition:
Sets the requirements that will qualify an object or a symbol before outputting a decode or message.
Bad Symbol Message Usage:
Can tell the user if a qualified symbol is present but not decodable.
Definition:
When enabled, send a message to the host whenever an object meets the qualifications setup in 1D/Stacked Symbology Qualification or 2D Symbology Qualificationbut is not decoded.
Serial Cmd:
<K715,[unused],message>
Default:
BAD_SYMBOL
Options:
Up to 128 ASCII characters (except NULL)
No Symbol Message Usage:
Can tell the user if a object does not qualify as a symbol.
Definition:
When enabled, send a message to the host whenever an object meets the qualifications setup in 1D/Stacked Symbology Qualification or 2D Symbology Qualificationbut is not decoded.
Serial Cmd:
<K716,[unused],message>
Default:
NO_SYMBOL
Options:
Up to 128 ASCII characters (except NULL)
1D/Stacked Symbology Qualification Minimum Number of Bars Definition:
Sets the minimum number of bars to qualify linear symbols.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scans,start/stop status>
Default:
0
Options:
0 to 255 (0 is disabled)
Quadrus Verifier User’s Manual
8-9
Page 250
Bad Symbol/No Symbol Qualification
Minimum Number of Qualified Scan Lines Definition:
Sets the minimum number of scans that have the required number of bars set in Minimum Number of Bars.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scans,start and stop status>
Default:
0
Options:
0 to 11 (0 is disabled)
Start/Stop Status Definition:
When enabled, both Start and Stop characters need to be present to qualify as a decodable symbol. In the case of PDF417, only a Stop or Stop needs to be present. Note: This parameter does not apply to UPC, Pharmacode, RSS and Micro-PDF417.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scans,start and stop status>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
2D Symbology Qualification Note: in the cases where Symbol Size Status, Dimension Status, or Orientation Status is enabled, the reader will always check the finder pattern regardless of Finder Pattern Status setting.
Finder Pattern Status Definition:
Checks for the presence of finder pattern.
Serial Cmd:
<K718,finder pattern status,symbol size mode,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Default:
Disabled
Options:
0 = Disabled
8-10
1 = Enabled
Quadrus Verifier User’s Manual