The text of a manual · part 23 of 47
Quadrus Verifier User's Manual, pages 221 to 230
Pages 221 to 230 of 470
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Verifier
Page 221
Symbologies
BC412 Usage:
It is widely used in the semi-conductor manufacturing and is particularly useful where speed, accuracy, and ease of printing are required.
Definition:
BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an alphanumeric symbol with a set of 35 characters, each encoded by a set of 4 bars in 12 module positions. All bars have a single width and it is the presence or absence of bars in each of the 12 module positions that make’s it a binary code (hence the prefix “BC”). The symbology is bi-directional and self-clocking with a start and stop character.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Output (BC412) Usage:
Check digit Output, added to the symbol, provides additional security.
Definition:
When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. Note: With Check Digit Output and an External or Serial trigger option enabled, an invalid check digit calculation will cause a No Read message to be transmitted at the end of the read cycle.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (BC412) Definition:
When enabled the reader will check the symbol length against the symbol length field. If disabled any length would be considered a valid symbol.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
Quadrus Verifier User’s Manual
1 = Enabled
7-11
Page 222
BC412
Fixed Symbol Length (BC412) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbology not having the specified length.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
10
Options:
1 to 64
7-12
Quadrus Verifier User’s Manual
Page 223
Symbologies
Interleaved 2 of 5 Usage:
Definition:
Serial Cmd: Default: Options:
It is has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode I 2/5 symbols. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Digit Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification. An error correcting routine in which the check digit character is added. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Digit Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:
When enabled, a check digit character is sent along with the bar symbol data for added data security. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Quadrus Verifier User’s Manual
7-13
Page 224
Interleaved 2 of 5
Symbol Length #1 (Interleaved 2 of 5) Usage:
Definition:
Serial Cmd: Default: Options:
With I 2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length # 2 to 0 (zero) to ensure data integrity is recommended. Allows user to define the symbol length. Because I 2/5 is a continuous symbology, it is prone to substitution errors. Hence, a symbol length must be defined and a bar code symbol must contain an even number of digits. Note: If a start, stop or check digits are used, they are not included in the symbol length count. <K472, status,check digit status,check digit output,symbol length #1,symbol length #2> 10 2 to 128, even only Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length # 1 for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character. Note: If both Symbol Length #1 and Symbol Length #2 are set to 0, then I–2/5 will be variable.
Symbol Length #2 (Interleaved 2 of 5) Usage:
Definition: Serial Cmd: Default: Options:
If using a second symbol, a zero or any even symbol length from 2 to 64 may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity. Allows user to define a second symbol length for I–2 of 5. <K472, status,check digit status,check digit output,symbol length #1,symbol length # 2> 6 2 to 128, even only Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character. Note: If both Symbol Length #1 and Symbol Length # 2 are set to 0, then I 2/5 will be variable.
7-14
Quadrus Verifier User’s Manual
Page 225
Symbologies
Guard Bar (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Usage:
It is useful when I 2 of 5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding the printed I 2 of 5 symbol and helping to prevent false reads.
Serial Cmd:
<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar>
Default:
Disabled
Options:
0 = Disabled
Quadrus Verifier User’s Manual
1 = Enabled
7-15
Page 226
UPC/EAN
UPC/EAN Usage:
Definition:
Serial Cmd: Default: Options:
Used primarily in POS application in the retail industry. It is commonly used with Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the Verifier will read UPC version A and UPC version E only. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
EAN Status (UPC/EAN) Usage:
Definition:
Serial Cmd: Default: Options:
7-16
EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the Verifier will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
Quadrus Verifier User’s Manual
Page 227
Symbologies
Supplementals Status (UPC/EAN) Usage: Definition:
Serial Cmd: Default: Options:
Reads Supplementals typically used in publications and documentation. A supplemental is a 2 or 5 digit symbol appended to the main symbol. When set to Enabled or Required, the Verifier reads supplemental bar code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled 2 = Required
Disabled UPC Supplementals will not be decoded. Enabled When enabled, the Verifier will try to decode a main and a supplemental. However, if a supplemental is not decoded, at the end of the read cycle, the main will be sent by itself. Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character, then the data will be displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC/EAN) Usage: Definition:
Serial Cmd: Default: Options:
Allows user to distinguish between the main and Supplemental symbols. Allows the user to insert a character between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled
Quadrus Verifier User’s Manual
7-17
Page 228
UPC/EAN
Separator Character (UPC/EAN) Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Usage: Definition:
As required by the application. Allows the user to change the separator character from a comma to a new character. Serial Cmd: <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Default: , (comma) Options: Any ASCII character Note: Whenever Separator Character is defined as a comma (,) sending a <K473,s?> command will return the current settings including the separator character comma which appears after the separator status comma.
Supplemental Type (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Both 0 = Both 1 = 2 char only 2 = 5 char only
Both Either 2 character or 5 character supplementals will be considered valid.
2 Characters Only Only two character supplementals will be considered valid.
5 Characters Only Only five character supplementals will be considered valid.
7-18
Quadrus Verifier User’s Manual
Page 229
Symbologies
Pharmacode Usage: Definition:
Serial Cmd: Default: Options:
Used mostly with packaging for the pharmaceuticals industry. Encodes up to five different numbers, each with its own color which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999999. In binary format, each input have up to 19 ones and zeros. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Definition: Serial Cmd: Default: Options:
When enabled, the reader will check the symbol length against the symbol length field. If disabled, any length would be considered a valid symbol. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Definition:
Serial Cmd: Default: Options:
This specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbology not having the specified length. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 10 4 to 16
Minimum Number of Bars (Pharmacode) Definition: Serial Cmd: Default: Options:
Sets the minimum number of bars that a pharmacode symbol must have to be considered as a valid symbol. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 4 4 to 16
Quadrus Verifier User’s Manual
7-19
Page 230
Pharmacode
Bar Width Status (Pharmacode) Definition:
Serial Cmd:
Default: Options:
If set to Mixed, it will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the Fixed Threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the reader is able to tell the difference between the narrow and the wide bars. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars, bar width status,direction,fixed threshold value> Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Decode Direction (Pharmacode) Definition: Serial Cmd:
Default: Options:
Specifies the direction that a symbol can be read. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars, bar width status,direction,fixed threshold value> Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Definition: Serial Cmd: Default: Options:
7-20
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. <K477,status,fixed symbol length status,fixed symbol length,min. no. of bars,bar width status,direction,fixed threshold value> 10 1 to 65535
Quadrus Verifier User’s Manual