Read Cycle

Capture Timing Note: Capture Timing applies only to Rapid Capture mode.

Time Before First Capture Usage:

In almost any moving line application, a time delay is needed to ensure that a symbol will be in the reader’s field of view at the beginning of the capture sequence.

Definition:

Time Before 1st Capture in a moving line application is the time between an external trigger event and the occurrence of the first capture.

Serial Cmd:

<K242,time before 1st capture,time between capture 1 and 2,,,,,,,,time between capture 7 and 8>

Default:

0

Options:

0 to 65535 (2.097seconds, in 32µS increments) Start of read cycle

Time Before First Capture

Processing

Time Before First Capture

Quadrus Verifier User’s Manual

6-23

Page 202

Capture Timing

Time Between Captures Usage:

This is useful in applications where more than one symbol can appear during a single read cycle (multisymbol), or where line speeds are slow enough that captured frames might overlap or miss a symbol.

Definition:

A time delay can be inserted between individual frame captures in the Rapid Capture mode.

Serial Cmd:

<K242,time before 1st capture,time between captures [time1,time2,...time7]> Entering 0’s will result in no time between captures (Diagram A). Entering a different value in each field will vary the time delays accordingly (Diagram B). Note: You must enter time values along with comma separators for each field you want to change. If you omit fields, or enter only commas, the fields will remain as previously set.

Default:

0

Options:

0 to 65535 (2.097seconds, in 32µS increments)

Note: Number of Captures and number of delays (Time Between Captures) must be the same. Start of Read Cycle Diagram A

Time Delay Between Captures = 0 End of read cycle

1 2 3 4 5

Time Delay Between Captures varies. Diagram B

Time Delay Between Captures

6-24

Quadrus Verifier User’s Manual

Page 203

Read Cycle

Dual Camera Switching Note: The following options are only available when Active Camera is set to Dual. Usage:

Useful where different symbols can appear within a single read cycle.

Definition:

When Active Camera is set to Dual, captures will alternate between the internal and external cameras, starting with the internal camera.

Important: The Quadrus Verifier does not control the timing of external cameras. Captures from external cameras are streamed into the Quadrus Verifier. To be sure to receive a complete first capture, allow up to 33 mS delay before the first external capture.

Switching Mode When Switching Mode is set to Number of Captures, the combined internal and external camera captures can not exceed the total number set in Number of Captures; however if the combined total is less than the total, then the capture pattern will be repeated until the total number of captures has been met. Definition:

Captures can be set to alternate between the internal and external cameras by the number of captures or by camera timeouts.

Serial Cmd:

<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>

Default:

Number of Captures

Options:

0 = Number Of Captures 1 = Timeout

Switching by Number of Captures Number of Internal Camera Captures Definition:

The number of captures taken by the internal camera before switching to the external camera.

Serial Cmd:

<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>

Default:

1

Options:

1 to 8

Quadrus Verifier User’s Manual

6-25

Page 204

Dual Camera Switching

Number of External Camera Captures Usage:

Useful where two cameras can expect different symbols within a given read cycle.

Definition:

The number of captures taken by the external camera before switching to the external camera.

Serial Cmd:

<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>

Default:

1

Options:

1 to 8

Rapid Capture Mode Examples Since examples 1 and 2 are in Rapid Capture mode, the cameras will continue to switch until the Number Of Captures setting has been met. Example # 1 Time Between Captures = 0, Active camera: Dual Capture mode: Rapid, Number of captures = 7 Number of internal camera captures = 5 Number of external camera captures = 3 Internal

1

2

3

4

Up to 33mS time delay before 1st external capture.

5 6

External

7

Processing

Note: The third capture for the external camera does not occur because the total number of captures (7) has been met. Note: In this mode, the first capture from an external camera (#6 is the above example) could be delayed for up to 33mS until the external camera synchronizes with the reader.

Example # 2 Time Between Captures = 0, Active Camera: Dual Capture Mode: Rapid, Number of captures = 8 Number of internal camera captures = 2 Number of external camera captures = 3 Extra 33mS time delay before 1st external capture. Internal External

1

2

6 3

4

5

7 8

Processing

Note: Since the total number of captures is greater than the combined number of captures of both cameras, capture source will oscillate between the two cameras until the total number (8) has been met.

6-26

Quadrus Verifier User’s Manual

Page 205

Read Cycle

Continuous Capture Mode Examples Continuous Capture mode is more involved due to the double buffering. The cameras will continue to switch for the duration of the read cycle in a double-buffered format, so that we start processing the first image while we are capturing the second. The third image will then start when both the first one is completely processed and the second is completely transferred.1 Example # 3 Time Between Captures = 0, Capture Mode: Dual Camera Number of internal camera captures = 5 Number of external camera captures = 3 Extra 33mS time delay before 1st external capture. Internal

1

2

3

4

5

External 1

Processing

2

3

4

6

7

8

5

6

7

8

Example # 4 Time Between Captures = 0, Capture Mode: Dual Camera Number of internal camera captures = 1 Number of external camera captures = 1 Extra 33mS time delay before 1st external capture. Internal External

1

3

5

2

Processing

7

4 1

2

9

6 3

4

5

8 6

10 7

8

9

1. Because of space limitations, a limited number of captures are shown in the Continuous examples.

Quadrus Verifier User’s Manual

6-27

Page 206

Dual Camera Switching

Switching by Timeout The timeout mode specifies the time each camera is active before switching to the other camera. The read cycle will start with the internal camera and switch to the external camera after the specified time period has expired.

Internal Camera Timeout Usage:

It is useful in many tightly controlled applications which require a read cycle to end before the next object appears and therefore need the flexibility of a timeout adjustment.

Definition:

Internal Camera Switching Time is the time span of the read cycle and is represented in 10mS increments. It is used in conjunction with External Edge or Serial Trigger.

Serial Cmd:

<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>

Default:

100 (x 10mS = 1 second)

Options:

0 to 65535 (Divide any positive number entered by 100 to determine the time in seconds.)

External Camera Timeout Usage:

It is useful in many tightly controlled applications which require a read cycle to end before the next object appears and therefore need the flexibility of a timeout adjustment.

Definition:

External Camera Timeout is the time allotted to the external camera and is represented in 10mS increments.

Serial Cmd:

<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>

Default:

100 (x 10mS = 1 second)

Options:

0 to 65535 (Divide any positive number entered by 100 to determine the time in seconds.)

Note: A minimum setting of 2 is recommended. Note: Timeout or Timeout or New Trigger under End of Read Cycle must be enabled for Timeout Duration to take effect.

6-28

Quadrus Verifier User’s Manual

Page 207

Read Cycle

Example of Timeout in Rapid Capture Mode Since examples 5 is in Rapid Capture mode, the cameras will continue to switch until the Number Of Captures setting has been met. Example # 5 Time Between Captures = 0 Capture Mode: Dual Camera Number of captures = 6 Internal camera timeout = 170mS External camera timeout = 160mS Internal

1

2

3

5

External

3

4

5

170ms

Timeout (Int)

170ms 160ms

Timeout (Ext) Processing

Note: The third and fifth captures were never completed since the active camera’s timeout occurred during the capture. When this occurs the capture is aborted and the active camera is switched.

Example of Timeout in Continuous Capture Mode Continuous Capture mode is a little more involved due to the double buffering. The cameras will continue to switch for the duration of the read cycle in a double-buffered format, so that we start processing the first image while we are capturing the second. The third image will then start when both the first one is completely processed and the second is completely transferred. Example # 6 Time Between Captures = 0 Capture Mode: Dual Camera Internal camera timeout = 100mS External camera timeout = 160mS Internal

1

2

5 3

External Timeout (Int)

100mS

100mS 160ms

Timeout (Ext) Processing

Quadrus Verifier User’s Manual

6

4

1

2

3

4

5

6

6-29

Page 208

Store No Read Image

Store No Read Image Note: Stored images will be lost whenever RAM is reset by re-powering or reset/save sequences, the capture mode is changed, or a read rate mode is initiated. Usage:

Useful for evaluating symbols and visually comparing images captured at various settings and conditions.

Definition:

Images that are captured and processed but are not decoded may be stored for subsequent evaluation.

Image Storage Type Usage:

Useful for evaluating symbols and visually comparing images captured at various settings.

Definition:

When Disabled is selected, all saved images will be cleared and no further images will be stored unless Store on No Read is selected.

Serial Cmd:

<K244,image storage type,image storage mode>

Default:

Disabled/Clear

Options:

0 = Disabled/Clear

1 = Store on No Read

Image Storage Mode Definition:

Outputs the first or last No Read images, as selected. In First mode, images will be stored until the available image memory has been filled. At this point the unit will stop storing additional images and the first images stored will be available. In Last mode, the last images stored will be available. After the available memory has been filled, images will continue to be stored by purging the oldest image in the storage memory.

Serial Cmd:

<K244,image storage type,image storage mode>

Default:

First Images

Options:

0 = First Images

6-30

1 = Last Images

Quadrus Verifier User’s Manual

Page 209

Read Cycle

Setting Up the Verifier for EZ Trax If you are using EZ Trax software, it is important to set up the Quadrus Verifier correctly before beginning. Click the Read Cycle button to display the Read Cycle tree control.

Set Trigger Mode, <K200>, to External Edge.

Set Capture Mode, <K241>, to Rapid Capture.

Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax software, or the EZ Trax Quick Start Guide, available on the Microscan Tools CD.

Quadrus Verifier User’s Manual

6-31

Page 210

Setting Up the Verifier for EZ Trax

6-32

Quadrus Verifier User’s Manual