Page 81

Setup

Capture Index Each index in the database (1 – 10) can be configured and tested individually.

Shutter Speed (CMOS) Sets the camera’s shutter speed (60 – 40,000, default 2,500) for the selected index.

Shutter Speed (Standard QX Hawk CCD) Sets the camera’s shutter speed (30 – 150,000, default 1,500) for the selected index.

Shutter Speed (QX Hawk C-Mount CCD) Sets the camera’s shutter speed (30 – 150,000, default 2,500) for the selected index.

Gain (CMOS) Sets the camera’s gain (0 – 33, default 20) for the selected index.

Gain (CCD) Sets the camera’s gain (0 – 64, default 20) for the selected index.

Focal Distance (Standard QX Hawk Only) Sets the camera’s focal distance (25 – 4,000, default 80) for the selected index.

Sub-Sampling (Standard QX Hawk Only) Sets the sub-sampling rate (4:1 or 16:1, Disabled by default) for the selected index. Important: Sub-Sampling has no effect when the “Image Dimension” mode is configured as Region of Interest in the Database Mode command. This is because the camera Window of Interest is determined by the software based on the database ROI setup and there is no benefit to sub-sampling to increase speed, as the frame size would have to be increased to account for the sub-sampling.

QX Hawk Industrial Imager User Manual

4-25

Page 82

Configuration Database

Morphology Operation Allows the user to select the method for processing captured images. Parameter values for serial command <K255>: 0 – Disable 1 – Erode 2 – Dilate 3 – Open 4 – Close

Morphology Size Determines the size of the area or “pixel neighborhood” (measured in pixels) in which the morphological operation is being performed. Parameter values for serial command <K255>: 3 – Small (3 pixels by 3 pixels) 5 – Medium (5 pixels by 5 pixels) 7 – Large (7 pixels by 7 pixels)

Top/Left/Height/Width (CMOS) The image dimension settings can be applied as a Window of Interest or a Region of Interest depending on the image dimension mode selected in the Database Mode command. Top: 0 to (480 – height) Default: 0 Left: 0 to (752 – width) Default: 0 Height: 3 to (480 – top) Default: 480 Width: 8 to (752 – left) Default: 752

Top/Left/Height/Width (CCD) The image dimension settings can be applied as a Window of Interest or a Region of Interest depending on the image dimension mode selected in the Database Mode command. Top: 0 to (960 – height) Default: 0 Left: 0 to (1280 – width) Default: 0 Height: 3 to (960 – top) Default: 960 Width: 8 to (1280 – left) Default: 1280

4-26

QX Hawk Industrial Imager User Manual

Page 83

Setup

Symbol Type This field allows the user to configure the database to operate on specific symbol types for selected database index. Symbol type-specific parameters must be configured with the appropriate symbol type command. For example, fixed length Code 128 is required; it must be set up with the Code 128 command <K474>. To configure a symbol type, simply add the number value associated with the symbol type to the field parameter. Example: If Data Matrix and Code 39 are required, the parameter would be 2 + 16 = 18. See I/O Parameters for a description of how to enter these values via serial command.

Disabled When disabled, the database uses the current Symbol Type setup to determine active symbol types.

Any Type All of the preceding symbol types, except Pharmacode, are enabled while this database index is being used. Add 1.

Data Matrix If enabled, Data Matrix will be active for this database index. Important: The ECC Level must be configured using the Data Matrix command <K479>. If no ECC level has been configured, then it will not decode a Data Matrix symbol. Add 2.

QR Code If enabled, QR Code will be active for this database index. Add 4.

Code 128 If enabled, Code 128 will be active for this database index. Add 8.

Code 39 If enabled, Code 39 will be active for this database index. Add 16.

Codabar If enabled, Codabar will be active for this database index. Add 32. QX Hawk Industrial Imager User Manual

4-27

Page 84

Configuration Database

Code 93 If enabled, Code 93 will be active for this database index. Add 64.

Interleaved 2of 5 If enabled, Interleaved 2of 5 will be active for this database index. Add 128.

UPC If enabled, UPC will be active for this database index. Add 256.

PDF417 If enabled, PDF417 will be active for this database index. Add 512.

MicroPDF417 If enabled, MicroPDF417 will be active for this database index. Add 1024.

BC412 If enabled, BC412 will be active for this database index. Add 2048.

Pharmacode If enabled, Pharmacode will be active for this database index. Add 4096.

DataBar-14 If enabled, DataBar-14 will be active for this database index. Add 8192.

DataBar Limited If enabled, DataBar Limited will be active for this database index. Add 16384. 4-28

QX Hawk Industrial Imager User Manual

Page 85

Setup

DataBar Expanded If enabled, DataBar Expanded will be active for this database index. Add 32768.

Micro QR Code If enabled, Micro QR Code will be active for this database index. Add 65536.

Aztec If enabled, Aztec will be active for this database index. Add 131072.

Current Postal Symbology If enabled, Current Postal Symbology will be active for this database index. Add 262144.

QX Hawk Industrial Imager User Manual

4-29

Page 86

Configuration Database

Database and Capture Modes The configuration database behaves the same for both “Rapid” and “Continuous” Capture Mode, the only discernable difference is in “Rapid” capture mode the database incrementing always operates in “Number of Image Frames” with a “frame count” of 1.

Camera Settings When the database loads a camera configuration and there is a change in shutter speed (integration time), window of interest (WOI), or sub-sampling from the last image that was captured; Then one image frame needs to be processed to setup the new configuration prior to capturing an image. The capture will start immediately following the integration period. If the image dimensions are configured as a Region of Interest (ROI), then a change to these values does not incur the additional image frame since it is no longer a camera setting. Since some image capture events require that an image frame delay occur and some don’t, this does complicate the image capture time when the Configuration Database is enabled. Notes: • If no camera change occurs, the start of the image capture is immediate upon being triggered. • If a camera change occurs, the start of the image capture occurs after the shutter time has completed. In the case above, the image capture would incur a 1ms delay.

Number of Active Indexes Number of database records (groups of settings) that will be used automatically during the read cycle. If set to 0, the imager only uses the current settings, not database entry settings.

Sort Database Activates a sort function that moves the database entry associated with the last decode to the first position in the database and moves all other entries up.

4-30

QX Hawk Industrial Imager User Manual

Page 87

Setup

Database Mode Switch Mode Selects the event that causes the imager to load the next entry from the database to current, active settings. When timer/count expires and “Image Process Looping” is enabled the next database entry that has a camera modification will be used. Notes: Capture event always occurs when the 1st database entry is used. This setting has no effect in Rapid Capture mode. Rapid Capture mode always operates in “Number of Frames” mode, with a “Frame Count” = 1.

Time The imager will load the next entry from the database to current after a defined time interval. The timer will start upon use of a database entry. In other words, if the timer expires during a capture event, the timer will not start again until the database entry has been incremented and the new entry has been loaded to current.

Number of Image Frames Database index is incremented after the specified number of image frames have been captured.

Frame Count/Time Indicates the “Number of Frames” that will occur or the amount of “Time” that is required before the imager will load the next database configuration. Timer resolution is 1ms.

Image Process Looping This feature is useful for processing a captured image frame multiple times with different Image Process/Decode parameters.

Disabled An image is captured for every database configuration, regardless if a camera setting has been modified.

Enabled When a database configuration is loaded to current, and the Camera settings have not changed from last capture event, a new image is not captured. But rather the last image frame that was captured is re-processed with the new Image Processing/Decode configuration. The one exception is with the 1st database index, a new image is always captured when the 1st database configuration is used. When a camera setting has been modified from one database setting to the next, a new image is captured. For example, if all database entries contained the same camera setting values, but had different IP/Decode configurations, the only time an image frame would be captured would be when the 1st database configuration was used. QX Hawk Industrial Imager User Manual

4-31

Page 88

Configuration Database

Image Dimensions This feature defines how the image dimension parameters are implemented.

Window of Interest (WOI) In this mode the database image dimension parameters are Camera Settings and dictate the size of the image to be captured.

Region of Interest (ROI) In this mode the database image dimension parameters are Image Processing\Decode Settings and specify the region or area of the captured image to be processed. The ROI coordinate data is based on the full scale image size. The WOI of the captured image will be configured to cover all the active database ROI settings. In the following example there are three active database setting, with different ROI configurations. Their coordinates are based at point 0,0 of the full scale image (SXGA = 1280 x 1024 or VGA = 640 X 480). The image WOI is not configurable, it is automatically setup by the database, based on the ROI settings. This feature is intended to be used in conjunction with the “Image Process Looping” feature, to allow processing different regions of a captured image with different Image Processing Decode Settings. In addition, if combined with “Output Filtering” the user can order the output of decoded symbols in a captured image frame by their location in the Field of View.

Multiple Symbols with Same Symbol Data Operation ROI can be used to decode more than one of the same symbols and treat them as different symbols. Multi Symbol Operation will work within the following rules: • Multiple symbols of same symbol data can only be handled by using ROI mode. This can only be done between different ROI IP Region settings. • ROI IP Region settings within the database must be sequential (Not Interlaced) in order to correctly know when a new region has been tried. If Database slot 2 and 3 are swapped, the imager would then treat them as 4 separate ROI regions. This would result in 4 different symbols with GDR of 1 instead of 2 different symbols with GDR count of 2. • ROI Regions will count the same symbol in the same region as additional decodes, but only spanning multiple frames. Each decode of same symbol with same ROI will add to the GDR count with additional frames. • Multiple symbols can be within each ROI Region but cannot identify multiple Same Symbols. If same symbol is in a ROI twice per frame then it will be counted as 1 decode or 1 more GDR count, the second will be ignored. • Filtering can only be done with database # because all other data is same.

4-32

QX Hawk Industrial Imager User Manual

Page 89

Setup

Ordered Output Output filtering is a method of providing a set of good read qualifiers and also providing ordered output. There is a filter for up to the first 10 positions in a multisymbol output. The first filter corresponds to the first symbol output at the end of the read cycle. Each filter has settings for the following parameters: Filter Number, Symbology Type, Length, Wildcard, Placeholder, Matching Data, Decode Direction, and Database Number. Filter Number, Symbology Type, Length, Wildcard, Placeholder, and Matching Data are all displayed in the table below. Double-clicking on any row of the table will display the Ordered Output Filter Settings dialog, where settings can be changed.

Receive settings from the imager, Send settings to the imager, or Send and Save settings.

Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable output filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 5, then filter indexes 1, 2, 3, 4, and 5 will be applied.

QX Hawk Industrial Imager User Manual

4-33

Page 90

Ordered Output

Filter Number This is the filter index number that represents the position of the symbol in the data output at the end of the read cycle. This index number should be entered along with the following filter settings for the predetermined symbol position.

Symbology Type Specifies the symbology type allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all the requirements of the selected filter index.

Length Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.

Wildcard This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.

Placeholder The placeholder character requires a character to be present, but does not compare the data value.

Matching Data This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”. 4-34

QX Hawk Industrial Imager User Manual