The text of a manual · part 8 of 46
QX Hawk Industrial Imager User Manual, pages 71 to 80
Pages 71 to 80 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 71
Setup
Height Defines the size, in rows, of the image window. Maximum value is defined as the Maximum row size of Image sensor, minus the row pointer value. A decrease in this value, coupled with an increase in the row pointer value, will cause an increase in frame rate at a resolution of 46 microseconds (row period).
Width Defines the size, in columns, of the image window. Maximum value is defined as the Maximum column size of Image sensor, minus the column pointer value. Changing this parameter will have no effect on frame rate.
QX Hawk Industrial Imager User Manual
4-15
Page 72
Camera Setup
Image Processing Settings Image Processing Timeout See Image Processing Timeout in Read Cycle.
Capture Mode See Capture Mode in Read Cycle.
Morphological Pre-Processing Morphological Pre-Processing allows the user to select the method for processing images, and to choose the operator size for that method. Important: This command must be set to Enabled for Morphological Operation to function.
Morphological Operation and Operator Size Operation Morphological Operation allows the user to select the method for processing captured images.
Erode Erode increases the dark cell size of a symbol. Useful for increasing the dark cell size of a dark-on-light Data Matrix symbol.
Dilate Dilate increases the light cell size of a symbol. Useful for increasing the light cell size of a light-on-dark Data Matrix symbol.
4-16
QX Hawk Industrial Imager User Manual
Page 73
Setup Open Open removes minor light defects of dark cells by performing a Dilate function followed by an Erode function.
Close Close removeV minor dark defects of light cells by performing an Erode function followed by a Dilate function.
Operator Size Operator Size determines the size of the area or “pixel neighborhood” (measured in pixels) in which the morphological operation is being performed.
Small (3 pixels by 3 pixels) Medium (5 pixels by 5 pixels) Large (7 pixels by 7 pixels)
QX Hawk Industrial Imager User Manual
4-17
Page 74
Evaluation
Evaluation In Evaluation, you can view images currently in the imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the imager. Click Receive to refresh this view. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.
4-18
QX Hawk Industrial Imager User Manual
Page 75
Setup
Histogram The Histogram function is useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level. Note: Since histograms are performed in the imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.
QX Hawk Industrial Imager User Manual
4-19
Page 76
Evaluation
Line Scan 1. From the Evaluation tab, click the Line Scan button. A window like that shown below will appear. 2. Drag your cursor horizontally across the image. This will create a dashed horizontal line. Pixel information and a visual representation of the dark and light pixels will be displayed below the image.
When you center your cursor over the dashed line, it becomes a double arrow cross. This allows you to move the line anywhere in the window. You can also use your keyboard arrows to move the line incrementally in any direction. As with the histogram, the line scan compares light and dark pixels, but in a spatial distribution. On the Y axis of the graph below, 0 is black and 255 is white; the X axis represents the horizontal axis of the symbol as described by the line scan. When you click anywhere on the graph, a vertical red line appears at that point and its position and value (in terms of black-to-white) are updated in the Pixel Info table to the left of the graph (237 in this example). In addition, a horizontal dashed red line is displayed that indicates the average value.
4-20
QX Hawk Industrial Imager User Manual
Page 77
Setup
Calibration The Calibration interface in ESP is a powerful and intuitive way to optimize the imager’s performance. It allows the user to control several complex, simultaneous calibration operations, and to follow the progress of those operations using cues such as progress bars, real-time representations of calibration values, and other dynamic user feedback.
ESP’s Calibration interface shown during a calibration routine
QX Hawk Industrial Imager User Manual
ESP’s Calibration interface shown after a calibration routine
4-21
Page 78
Window of Interest
Window of Interest The active pixel area of the image sensor is called the Window of Interest (WOI). The WOI allows the user to select an area of the field of view in which the desired symbol is located. The programmable window of interest increases decode speed, improves threshold, and makes it easy to select specific symbols from among several in the field of view. The user provides the upper-left pixel location and the size of the window to define the Window of Interest. Window of Interest (CMOS)
Window of Interest (CCD)
Caution: Window of Interest will shrink the field of view and therefore could cause symbols to be missed in dynamic applications.
4-22
QX Hawk Industrial Imager User Manual
Page 79
Setup
Window of Interest Graphic Interface 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.
Note: To remove the window of interest, click the Reset button or click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the imager has far less processing to do in a smaller window, read rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. QX Hawk Industrial Imager User Manual
4-23
Page 80
Configuration Database
Configuration Database The Configuration Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters.
Configuration Database view, CMOS, set for 5 Active Indexes, with Capture Settings highlighted As soon as the number of active database settings is something other than 0, the database is enabled. Once enabled, the current configuration settings (that are handled by the database) have no impact on imager operation.
4-24