The text of a manual · part 7 of 46
QX Hawk Industrial Imager User Manual, pages 61 to 70
Pages 61 to 70 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 61
Setup
Camera Setup Click the App Mode button and then the Setup button. You will see the Camera Setup tree control to the right of the Video interface.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Communication settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format.
QX Hawk Industrial Imager User Manual
4-5
Page 62
Camera Setup
CMOS (WVGA) Camera Settings
Gain Sets the gain value for the image sensor. This setting can be configured through autocalibration, and is the recommended method for configuring this settings. A higher value will increase the brightness of the image, but the noise performance of the system is reduced. Prior to configuring the gain, the required shutter speed should be set, and the gain should be configured to optimize the shutter speed setting.
Shutter Speed This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If an object is moving fast and a slow shutter speed is selected, blurring or smearing of the object will occur. As shutter speed is increased the amount of light required or gain needed has to be increased since the pixels exposure time has decreased.
4-6
QX Hawk Industrial Imager User Manual
Page 63
Setup
CCD (SXGA) Camera Settings
Gain Sets the gain value for the image sensor. This setting can be configured through autocalibration, and is the recommended method for configuring this settings. A higher value will increase the brightness of the image, but the noise performance of the system is reduced. Prior to configuring the gain, the required shutter speed should be set, and the gain should be configured to optimize the shutter speed setting.
Shutter Speed This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If an object is moving fast and a slow shutter speed is selected, blurring or smearing of the object will occur. As shutter speed is increased the amount of light required or gain needed has to be increased since the pixels exposure time has decreased.
QX Hawk Industrial Imager User Manual
4-7
Page 64
Camera Setup
Illumination Type (Standard QX Hawk Only) Mode Configures the illumination pattern. “Bright Field” is used for most applications. For Mode 4, the internal illumination is always off, similar to configuration setting 0 (Always Off).
Bright Field
Mode 2
Mode 3
Mode 4 (Internal LEDs Off)
Brightness Configures the amount of illumination output from the unit’s built-in lighting.
4-8
QX Hawk Industrial Imager User Manual
Page 65
Setup
External Smart Light (QX Hawk C-Mount Only)
Disabled When External Smart Light is set to Disabled, the external smart light control is disabled and Output 3 is available for any other operation.
Always On When External Smart Light is set to Always On, the external smart light is continuously on.
Always Off When External Smart Light is set to Always Off, the external smart light is continuously off.
On Only When in Read Cycle When External Smart Light is set to On Only When in Read Cycle, the external smart light will be on when the imager is in an active read cycle. Important Note: The external smart light's active state is controlled through the Output State of Output 3, which is used as the external control line. To control the external light using a Microscan standard 12-pin-to-5-pin external light control cable, set Output 3's Output State to Normally Closed and Output Common to ground. Any other settings that relate to Output 3, such as Output 3 Diagnostics will be ignored if this mode is enabled. The external light will be continuously on until the system is fully re-booted.
QX Hawk Industrial Imager User Manual
4-9
Page 66
Camera Setup
Focus Distance Provides focal distance adjustment for the camera. Focus Distance limits are determined by the lens model and are defined in the table below. Any value outside this range will be rejected.
When Distance Units is set to millimeters, the focal distance parameter has a range of 25 to 4000. When Distance Units is set to 1/100 inch, focal distance is limited to a range of 100 to 4000. If you attempt to set the focal distance to less than 100 (1 inch), the parameter will be set to 100.
Distance Units Defines the measurement unit value of the Focus Distance parameter. Distance Units can be set to millimeters or inches.
4-10
QX Hawk Industrial Imager User Manual
Page 67
Setup
Sub-Sampling The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be specified as either 4:1 or 16:1, which signifies the sampling rate. Note: Sub-Sampling is not available for the CCD model of the QX Hawk.
4:1 1 pixel output for every 4 pixels sampled. When selected the image will be sampled 2:1 in the vertical direction and 2:1 in the horizontal direction for a combined 4:1 ratio. An image with a dimension of 640 x 480 will be scaled to 320 x 240.
16:1 1 pixel output for every 16 pixels sampled. When selected the image will be sampled 4:1 in the vertical direction and 4:1 in the horizontal direction for a combined 16:1 ratio. An image with a dimension of 640 x 480 will be scaled to 160 x 120.
QX Hawk Industrial Imager User Manual
4-11
Page 68
Camera Setup
CMOS (WVGA) Window of Interest
The active pixel area of the image sensor is defined as the “Window of Interest” (WOI). This allows the user to select an area in the Field of View that the desired symbol will be located. The programmable window of interest is useful for increasing decode speed, improving threshold, selecting desired symbol from multiple symbols in FOV. The user provides the upper-left pixel location and the size in both rows and columns to define the Window of Interest.
Important Notes: • The column width value is required to be a modulus 32 value, so regardless of the column width setting that is configured the actual column width will be decreased (if required) to a modulus 32 value. For example a column width value of 632 would actually be 608. A user request of this setting would still return 632. • The column pointer is required to be an even value, so regardless of the column pointer setting that is configured the actual column pointer will be decreased (if required) to an even value. For example a column pointer value of 101 would actually be 100. A user request of this setting would still return 101.
Top Defines the row position of the upper-left starting point of the image window.
Left Defines the column position of the upper-left starting point of the image window.
4-12
QX Hawk Industrial Imager User Manual
Page 69
Setup
Height Defines the size, in rows, of the image window. Maximum value is defined as the Maximum row size of Image sensor, minus the row pointer value.
Width Defines the size, in columns, of the image window. Maximum value is defined as the Maximum column size of Image sensor, minus the column pointer value.
QX Hawk Industrial Imager User Manual
4-13
Page 70
Camera Setup
CCD (SXGA) Window of Interest
The active pixel area of the image sensor is defined as the “Window of Interest” (WOI). This allows the user to select an area in the Field of View that the desired symbol will be located. The programmable window of interest is useful for increasing decode speed, improving threshold, selecting desired symbol from multiple symbols in FOV. The user provides the upper-left pixel location and the size in both rows and columns to define the Window of Interest.
Important Notes: • The column width value is required to be a modulus 32 value, so regardless of the column width setting that is configured the actual column width will be decreased (if required) to a modulus 32 value. For example a column width value of 632 would actually be 608. A user request of this setting would still return 632. • The column pointer is required to be an even value, so regardless of the column pointer setting that is configured the actual column pointer will be decreased (if required) to an even value. For example a column pointer value of 101 would actually be 100. A user request of this setting would still return 101.
Top Defines the row position of the upper-left starting point of the image window. An Increase in this value will cause an increase in frame rate at a resolution of 46 microseconds (row period). If this value is changed and the resulting combination of row pointer plus row depth exceeds the maximum allowed, the row depth will be decreased to an acceptable value.
Left Defines the column position of the upper-left starting point of the image window. If this value is changed and the resulting combination of column pointer plus column width exceeds the maximum allowed, the column width will be decreased to an acceptable value.
4-14
QX Hawk Industrial Imager User Manual