Page 51

Hardware Installation

QX-1 Interface Device The QX-1 Interface Device’s receptacles are physically the same as those on the QX Hawk, but they do not have explicit pin assignments. The QX-1 allows users to bus power and communications as required by the application. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. 1, 3 1,3, T

PWR TRIG

1,2, 3 1,2, 3, T

QX-1 Interface Device Pin 1 2 3 4

Assignment + 10-28V Trig/NM/Input 1 Common Ground Trigger

QX-1 Trigger Connector 4-pin Socket This simple diagram (shown on the base of the QX-1) illustrates how power, communications, I/O, and trigger signal can be routed through the QX-1 device depending on the needs of the application. The switches greatly increase signal routing flexibility.

QX-1 Communications - I/O Power - Trigger

QX Hawk Industrial Imager User Manual

3-7

Page 52

Power and Trigger Switching

Power and Trigger Switching

1, 3 1,3, T

3-8

PWR TRIG

1,2, 3 1,2, 3, T

Power can be bussed between imagers and interface devices. At each location on a network where a new power supply is added, the Power switch on the QX-1 can be used to break power between Connector 2 and Connectors 1, 3, and T. The Trigger signal between Connector 2 and Connectors 1, 3, and T can be broken using the Trigger switch. This isolates trigger signals as required by the application.

QX Hawk Industrial Imager User Manual

Page 53

Hardware Installation

Port Routing The physical advantages created by flexible signal routing and switching are enhanced further by Port Routing, which can be configured in ESP. Port Routing eliminates the need for dedicated “Host” and “Aux” ports in a traditional sense. With Port Routing, any port can be defined as a Host or Aux port. Port Routing also allows users to define the data types that are accessible from specific ports. The primary benefit of Port Routing is that any type of data can be routed to any port, and can be sent through multiple ports simultaneously. Multiple types of data can also be appended to the symbol data that is output from the imager to the host. Command data, symbol data, extended data, and diagnostic data are enabled by default in the QX Hawk. The table below lists different types of data, with examples for each data type. Data Type

Example

Command Data

Serial commands; imager responses to serial commands.

Symbol Data

Any string of data encoded in a symbol.

Extended Data

Decodes per trigger, decode direction, configuration database index number.

Diagnostic Data

Service message.

The screen capture below (from ESP) shows the QX Hawk’s four communications ports and the parameters for each.

RS-232 A, RS-232 B, and RS-422 are serial. RS-232 A is always enabled. RS-232 B and RS-422 can be enabled or disabled to match the physical requirements of the application. Ethernet can also be enabled or disabled as required. RS-232 A, RS-232 B, and RS-422 can be configured for Baud Rate, Parity, Stop Bits, Data Bits, Symbol Data Output, Extended Data (Decodes Before Output, Symbol Position Output, etc.), Diagnostics Output, and External Source Processing Mode (Command or Data). Ethernet can be configured for IP Address, Subnet Mask, Gateway, IP Address Mode, Symbol Data Output, Extended Data, Diagnostics Output, and External Source Processing Mode.

QX Hawk Industrial Imager User Manual

3-9

Page 54

Application Examples

Application Examples The following examples demonstrate how the components described in previous pages can be deployed in industrial applications.

Daisy Chain Daisy chain configurations are used in applications such as product packaging, where single items have multiple symbols. For example, a box with one symbol on the top and symbols on either side requires at least three imagers to ensure that all symbols will be decoded. The highlighted areas below demonstrate how a daisy chain can be arranged. One imager is placed above the conveyor line and one imager is placed on each side of the line. The three imagers essentially function as a single imager, and data is sent from the primary imager to the host or PLC. Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain.

3-10

QX Hawk Industrial Imager User Manual

Page 55

Hardware Installation

Multidrop Multidrop networks are used in applications where it is necessary to decode symbols at multiple locations within an industrial process. Imagers are placed at stations located between manufacturing steps, and data from those imagers is directed to a multidrop concentrator before being sent to a host. An example of this type of application is food packaging, in which part number data is collected and tracked throughout the packaging process. The highlighted areas below demonstrate how a multidrop network can be arranged.

QX Hawk Industrial Imager User Manual

3-11

Page 56

Application Examples

Ethernet TCP/IP Ethernet TCP/IP is the standard Ethernet interface used to connect multiple locations in a network, such as computers in an office network. It can also be used to network other communications devices, such as imagers and PLCs on a factory floor. The highlighted areas below demonstrate how an Ethernet daisy chain can be arranged. Ethernet-enabled imagers can also be set up in standalone configurations, or multiple Ethernet-enabled imagers along a production or packaging line can be connected to Ethernet.

3-12

QX Hawk Industrial Imager User Manual

Page 57

4 Setup Contents Video............................................................................................................................................. 4-2 Evaluation ................................................................................................................................... 4-18 Calibration................................................................................................................................... 4-21 Window of Interest ...................................................................................................................... 4-22 Configuration Database .............................................................................................................. 4-24 Ordered Output........................................................................................................................... 4-33 Output Format............................................................................................................................. 4-37 Dynamic Setup ........................................................................................................................... 4-41

This section describes ESP’s Setup interfaces: Video, Evaluation, Calibration, Window of Interest, Configuration Database, Ordered Output, Output Format, and Dynamic Setup. Each interface allows the user to make changes to imager configuration quickly and easily.

QX Hawk Industrial Imager User Manual

4-1

Page 58

Video

Video The Video view allows the user to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features simple Capture and Decode functionality.

4-2

QX Hawk Industrial Imager User Manual

Page 59

Setup

Learn The Learn command, located in ESP’s EZ Mode and in the Setup section on the Video tab, puts the QX Hawk into a mode of operation that will cause it to “learn” the next Data Matrix symbol decoded. Learn Mode remains active until either a Data Matrix symbol is decoded or Learn Mode is disabled by re-clicking the Learn button. Upon decoding a Data Matrix symbol, the QX Hawk’s image processing will save pertinent information about the learned symbol so that subsequent identical symbols will be processed more quickly. See Learn Operations in Utilities for other Learn commands that can be sent serially. Click the Learn button to start Data Matrix Learn Mode.

The Learn button will say “Learning” during the learn operation.

The Learn button will say “Learned” when the Data Matrix symbol has been learned.

The learn state and parameters persist in the same way as ordinary parameters. Examples: • A QX Hawk in a Learned state has not been saved. Cycling power will remove any Learned state information and the imager will power-on in its configured state. • A QX Hawk is saved in a Learning state. The imager will power-on in the Learning state and will learn the first Data Matrix symbol decoded. • A QX Hawk is saved in a Learned state. The imager will power-on in the Learned state and will only decode the learned symbol type. • A QX Hawk in a Learned state is issued a reset default command <Ard>. The unit will return to an Unlearned state but if power is cycled it will return to its saved state. QX Hawk Industrial Imager User Manual

4-3

Page 60

Video

Select Lens (Standard QX Hawk Only) If you change the QX Hawk’s lens, you must configure the Lens Type parameter to match the new lens type. Click the Select Lens button on the Video tab. To verify the lens type of your camera, power-off the QX Hawk (do not look into the targeting laser) and look at the outer rim of the unit’s camera lens. You will see one of the following: ‘●’ and ‘15’ = Lens Type 1 ‘●●’ and ‘30’ = Lens Type 2 ‘●●●’ and ‘45’ = Lens Type 3 (Default) ‘○’ and ‘12’ = Lens Type 4 Select your lens type in the Select Reader Optics dialog and click OK. You can calibrate the new lens by using the <@OPTIC> command. Important: <@OPTIC> is not supported by the QX Hawk C-Mount Imager. This parameter is “sticky”. Once saved with a <Z> or <Zc> command, it can only be defaulted with <Zrdall> or <K525d>.

4-4

12 Degree Lens

15 Degree Lens

30 Degree Lens

45 Degree Lens QX Hawk Industrial Imager User Manual