Page 41

Using ESP

Navigating in ESP To change imager settings, or to access the Setup, Terminal, or Utilities views, click the App Mode button.

To return to EZ Mode, click the EZ Mode button.

To make changes to configuration settings in the tree controls:

1. Left-click on the + to expand menu items.

The X indicates that the setting is default.

2. Double-click the desired parameter and single-click in the selection box to view options. 3. Place the cursor in the selection box, scroll down 4. Left-click again on the open screen to complete the to the desired setting, and selection. single-click the setting. 5. Right-click on the open screen and select Save to Reader to implement the command in the imager. The command can be sent without saving, or sent and saved simultaneously.

QX Hawk Industrial Imager User Manual

2-15

Page 42

Send/Receive Options

Send/Receive Options To access Receive, Save, and Default options, click the Send/Recv button. These options can also be reached by right-clicking in any of the configuration views.

Receiving From the Send/Recv menu, select Receive Reader Settings. Caution: Selecting this option will upload the imager’s settings. If the ESP file has a number of custom settings that must be maintained and downloaded into the imager, these settings will be lost. This function is useful for receiving (uploading) the imager’s settings and saving them as a file for future use. For example, if the imager has settings that must not change, Receive Reader Settings would load those settings to ESP and save them in an ESP file for later retrieval. Receiving the imager’s settings will also assure that any unwanted subsequent changes in ESP will not be saved.

Saving Send, No Save (<A>) Saves ESP settings to current memory.

Send and Save (<Z>) Activates all changes in current memory and saves to the imager for power-on.

Send and Save as Customer Defaults (<Zc>) Saves default settings for quick retrieval. This option will be visible only if Enable ‘Send and Save as Customer Defaults’ is checked in ESP Preferences.

2-16

QX Hawk Industrial Imager User Manual

Page 43

Using ESP

Defaulting When Default Current Menu Settings or Default all ESP Settings are selected, only the ESP settings are defaulted.

Advanced Options Send Current View This is the same as Save to Reader > Send No Save except that only the commands in the current configuration tree are sent.

Send Current Command This is the same as Send Current View, except that it saves only the command that is currently selected.

Add/Remove Exception After a Receive Reader Settings command is performed1 and the Add Exception option is selected, a list of serial commands may appear. These are commands that may be in the imager’s firmware, but are not included in, or are different from, the current version of ESP. These commands can be edited by double-clicking them and changing them as needed. It is important to note that these commands will be saved to the imager whenever a Save to Reader command is sent, or when an <A> or a <Z> command is sent. Also, if there is a corresponding ESP menu item, the ESP Value column for that item will be blank following a Receive Reader Settings command.

1. From the Send/Recv button or by right-clicking in any blank section of a tree control view.

QX Hawk Industrial Imager User Manual

2-17

Page 44

Send/Receive Options

2-18

QX Hawk Industrial Imager User Manual

Page 45

3 Hardware Integration Contents Cordsets ....................................................................................................................................... 3-2 QX Hawk and QX-1 Connectors and Pinouts............................................................................... 3-3 Power and Trigger Switching........................................................................................................ 3-8 Port Routing.................................................................................................................................. 3-9 Application Examples ................................................................................................................. 3-10

This section introduces the details of QX Hawk hardware, and explains how that hardware can be integrated in an application.

QX Hawk Industrial Imager User Manual

3-1

Page 46

Cordsets

Cordsets The terms “cordset” and “cable” are both applicable to industrial connectivity, but they are not synonymous. Cordsets enable communications and power between imagers and interface devices. Cordsets have an M12 connector at one or both ends. Examples of cordsets are shown below.

M12 to M12 Cordset

M12 to RJ45 (Ethernet) Cordset

M12 to Photo Sensor Cordset

Cables do not have M12 connectors at either end. An example of a cable is shown below.

Cable with flying leads

3-2

QX Hawk Industrial Imager User Manual

Page 47

Hardware Installation

QX Hawk and QX-1 Connectors and Pinouts When deploying a network of imagers and interface devices in an industrial setting, it is important to use components whose pin assignments are arranged in a way that avoids communication errors and equipment damage. This can be achieved with components that are designed in a logical, consistent, and easy-to-implement way. The QX Hawk has a very simple pin assignment methodology. The clearly identified connectors at the back of the unit can be used to receive and bus power, and also to send and receive data and commands. QX Hawk Connectors

A is a serial M12 12-pin plug. It is the same for all models of the QX Hawk. B is a serial M12 12-pin socket for serial models and an Ethernet M12 8-pin socket for Ethernet models. Output 2 New Master

Default Power

Output 1

RS-232 (Host) TxD

Output 3

Trigger Ground RS-232 (Host) RxD

Input Common Output Common

A (All Models) M12 12-pin Plug Pin 1 2 3 4 5 6 7 8 9 10 11 12

Function Trigger Power Default New Master Output 1 Output 3 Ground Input Common RS-232 (Host) RxD RS-232 (Host) TxD Output 2 Output Common

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

Continued next page QX Hawk Industrial Imager User Manual

3-3

Page 48

QX Hawk and QX-1 Connectors and Pinouts

QX Hawk and QX-1 Connectors and Pinouts (continued) RS-422/485 RxD (–) Input Common

RS-232 TxD/ RS-232 RTS Trigger

Ground

RS-232 RxD/ RS-232 CTS

RS-422/485 RxD (+)

Power

RS-422/485 TxD (+)

Terminated

RS-422/485 TxD (–)

RX (+)

Function Trigger Power Terminated Input 1 Port 3 422/485 TxD (+) Port 3 422/485 RxD (+) Ground Input Common Port 2 TxD/Port 1 RTS Port 2 RxD/Port 1 CTS Port 3 422/485 TxD (–) Port 3 422/485 RxD (–)

TX (–) Terminated

B (Serial) M12 12-pin Socket

3-4

Terminated

RX (–)

Terminated Input 1

Pin 1 2 3 4 5 6 7 8 9 10 11 12

Terminated

TX (+)

Wire Color White Brown Green Yellow Gray Pink Blue Red Black Violet Gray/Pink Red/Blue

B (Ethernet) M12 8-pin Socket Pin 1 2 3 4 5 6 7 8

Function Terminated Terminated Terminated TX (–) RX (+) TX (+) Terminated RX (–)

QX Hawk Industrial Imager User Manual

Page 49

Hardware Installation

Grounding the QX Hawk Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.

QX Hawk

An earth ground is provided through the cable shields and chassis of the imager.

Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, imager, and their power supplies are connected to a common earth ground.

QX Hawk Industrial Imager User Manual

3-5

Page 50

QX Hawk and QX-1 Connectors and Pinouts

Expected Power and Ground Connections for Proper Operation

Grounding Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the imager. • “Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.

3-6

QX Hawk Industrial Imager User Manual