Page 91
Setup
Ordered Output Filter Settings
Double-clicking on a row in the Ordered Output table brings up the Ordered Output Filter Settings dialog. Use these settings to determine Symbology Type, Length of the symbol, a user-defined Matching String, ASCII Lookup, Wildcard Character, Placeholder Character, and Database Number. Click Apply to save the settings to the corresponding filter.
QX Hawk Industrial Imager User Manual
4-35
Page 92
Ordered Output
Rules for Output Filter Configuration Output Filter Configuration Rule # 1 Each symbol that is decoded must match one of the filters before it can be saved to a read cycle record. There is an exception to this rule, however, when the number of symbols required for a read cycle exceeds the number of active filters. In such a case, unfiltered symbols can be placed into unfiltered output positions. For example, if the number of symbols required is 6 but there are only 5 active filters, the last position can be filled by any (unfiltered) qualified symbol.
Output Filter Configuration Rule # 2 The same filter setup can be used multiple times. For example, filters 1, 2, and 3 can be set up to filter Code 39 symbols, and the output will occur in the order the symbols are decoded.
Output Filter Configuration Rule # 3 All qualified symbols will be sorted and output in the matching filter position. If a symbol matches filter 3, it will be output as the third symbol. If a filter does not have a matching qualified symbol, a No Read message will be output in place of the symbol (assuming the No Read message is enabled). For example, if there is not a symbol that meets filter 3’s requirements, then a No Read message will be output in the third output position.
4-36
QX Hawk Industrial Imager User Manual
Page 93
Setup
Output Format Enable Output Format This is a global enable/disable parameter. Use Set Number of Symbols and Output Phrase to assign symbols for formatting, and Symbol Parse to determine the specific output content for the assigned symbols. On the Output Format tab, check the Enable Output Format box.
QX Hawk Industrial Imager User Manual
4-37
Page 94
Output Format
Set Number of Symbols Number of Symbols determines the number of symbols to which output formatting will apply.
Output Phrase Output Phrase refers to the user-defined Preamble, selected symbols, and Postamble sequence in the read cycle result. Use the Set Number of Symbols spin box to determine the number of symbols to be included in the output phrase.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
4-38
Check the Parse boxes beneath the symbols to be formatted.
Enter Postamble characters by double-clicking in the text field and then using the Postamble calculator.
QX Hawk Industrial Imager User Manual
Page 95
Setup
Symbol Parse Extract
The Extract Range function corresponds to the Start Location and Length parameters in the Format Extract serial command.
Multiple character sequences can be extracted and inserted using Symbol Parse. In this example, the selected extraction range is characters 2-4. The “Sample Symbol” example on the Symbol Parse dialog shows the selected character positions extracted and output as desired. Simultaneously, the data string from the selected symbol is displayed at the bottom left of the Parse Table, followed by the user-defined extracted output.
QX Hawk Industrial Imager User Manual
4-39
Page 96
Output Format
Insert
The Insert process is very similar to the Extract process, except that Insert allows the user to enter characters using the Insert calculator (shown above).
Notice that Extract and Insert share the same Parse Table.
4-40
QX Hawk Industrial Imager User Manual
Page 97
Setup
Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.
Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures. The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.
The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.
QX Hawk Industrial Imager User Manual
4-41
Page 98
Dynamic Setup
4-42
QX Hawk Industrial Imager User Manual
Page 99
5 Parameters Contents Communication ............................................................................................................................. 5-2 Read Cycle ................................................................................................................................. 5-42 Symbologies ............................................................................................................................... 5-62 I/O Parameters............................................................................................................................ 5-98 Symbol Quality.......................................................................................................................... 5-159 Matchcode ................................................................................................................................ 5-166 Diagnostics ............................................................................................................................... 5-175
This section explains the function and purpose of the Parameters commands in ESP’s tabbed tree controls. Important: Unless otherwise specified, command settings shown in this section are the default settings.
QX Hawk Industrial Imager User Manual
5-1
Page 100
Communication
Communication Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Communication tab to display the Communication tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Communication settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the Communication section of Appendix E.
5-2
QX Hawk Industrial Imager User Manual