Page 431
Appendices 15. Select one CPS instruction per rung, the “_small_pt” on the left, or the “_big_pt” on the right. Keep the one that corresponds to the assembly sizes configured for the module, and delete the other:
16. In this example, the small assembly set has been kept:
QX Hawk Industrial Imager User Manual
A-115
Page 432
Allen-Bradley Version 16 PLC Setup In this example, the big assembly set has been kept:
For the remainder of this document, the big assembly set is demonstrated. The system is now configured enough to test communication with QX Hawk. 17. Select the control button next to “Offline”, and select “Download”:
A-116
QX Hawk Industrial Imager User Manual
Page 433
Appendices 18. Once the program has downloaded, make sure the PLC is in Run Mode:
19. To open the Program Tags, right-click on “Program Tags” and select “Monitor Tags”:
QX Hawk Industrial Imager User Manual
A-117
Page 434
Allen-Bradley Version 16 PLC Setup 20. Expand the “QXHawk_IO_big_pt” so that the .IN and .OUT structures and values are visible:
21. Change the “.OUT.usertag” to non-zero:
A-118
QX Hawk Industrial Imager User Manual
Page 435
Appendices The “.IN.usertag_echo” will change to match the same value as the “.OUT.usertag”:
This confirms that two-way communication with QX Hawk is successful. It is left to the programmer to move or modify the CPS instructions in the Main Program according to the application’s requirements. Operation of the data fields within the assemblies is described in the object model documentation.
QX Hawk Industrial Imager User Manual
A-119
Page 436
Allen-Bradley Version 20 PLC Setup
Appendix K, Allen-Bradley Version 20 PLC Setup • To add a new EDS file to RSLogix 5000 Version 20 select the EDS Hardware Installation Tool from the menu item under Tools.
• Click the Next button.
A-120
QX Hawk Industrial Imager User Manual
Page 437
Appendices • Make sure the Register an EDS file(s) radio button is selected, then click Next.
• Click the Browse button to locate the new EDS file on your PC. Then click Next.
QX Hawk Industrial Imager User Manual
A-121
Page 438
Allen-Bradley Version 20 PLC Setup • Click the Next button.
• Click the Next button.
A-122
QX Hawk Industrial Imager User Manual
Page 439
Appendices • Click the Next button.
• Click the Finish button.
QX Hawk Industrial Imager User Manual
A-123
Page 440
Allen-Bradley Version 20 PLC Setup • Now the EDS file has been loaded into RSLogix’s database. Right-click the Ethernet menu item and select New Module.
• To find your camera in the list, type fis and the dialog will show only devices with the letters “fis” in the name. Either double-click the camera you want or highlight it and click the Create button.
A-124
QX Hawk Industrial Imager User Manual