Page 441

Appendices • Enter the name of the device used in the PLC program and the IP address of the camera.

• After the new device has been added to the project, the default assembly data will be the small size. You can change it to large by double-clicking the camera menu item in the tree control and clicking the Change button on the dialog.

QX Hawk Industrial Imager User Manual

A-125

Page 442

Allen-Bradley Version 20 PLC Setup • Select the large assembly size and click the OK button when done.

A-126

QX Hawk Industrial Imager User Manual

Page 443

Appendices

Testing Communications Using Controller Tags • Open the Controller Tags dialog and select the Monitor Tags tab at the bottom. Then expand the output array. The trigger bit is the first bit of the 5th byte offset which is data[4].0. Setting this bit to 1 should trigger a read on the camera.

QX Hawk Industrial Imager User Manual

•

A-127

Page 444

Allen-Bradley Version 20 PLC Setup • The read data will be in the input array. For the IO_small connection size scroll down to where data[16] is the first byte of the read data length and data[20] is the start of the data string.

• For the IO_big connection size scroll down where data[44] is the first byte of the read data length and data[48] is the start of the data string.

A-128

QX Hawk Industrial Imager User Manual

Page 445

Appendices • The input data assembly is as follows.

Note: If the camera fails to read, make sure to enable External Trigger in ESP.

QX Hawk Industrial Imager User Manual

A-129

Page 446

Allen-Bradley Version 20 PLC Setup

Using Add-On-Instruction Tags • Insert the new AOI into the program. Create the proper tags and associated links.

• Open the Program Tags dialog and trigger a read by changing the output tag from 0 to 1.

A-130

QX Hawk Industrial Imager User Manual

Page 447

Appendices • Expand the input assembly and verify that the read data has populated the tags.

• Below is a screen shot of the small input assembly data.

QX Hawk Industrial Imager User Manual

A-131

Page 448

EIPScan Setup

Appendix L, EIPScan Setup This procedure is for the EIPScan Test Tool published by Pyramid Solutions. 1. Right-click on “EIPScan Test Tool”, select “Add Device”:

2. Set the “IP Address” to match QX Hawk:

A-132

QX Hawk Industrial Imager User Manual

Page 449

Appendices QX Hawk will show up in the main window:

3. Right-click on QX Hawk, select “Add Class1 Connection”:

QX Hawk Industrial Imager User Manual

A-133

Page 450

EIPScan Setup 4. When the “Add Class1 Connection” dialog pops up, select “Data Size”. 5. Populate “Originator->Target” (OUT) with 12, and “Target->Originator” (Big IN) with 176:

Alternately, “Target->Originator” could be set to 84 for the Small IN assembly. 6. Select “Rate”, and set packet rate to 20 milliseconds in both directions:

A-134