The text of a manual · part 43 of 46
QX Hawk Industrial Imager User Manual, pages 421 to 430
Pages 421 to 430 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 421
Appendices
Programming Flow Charts Triggered by PLC, symbol data required, timeout or decode ends read cycle. Setup: Read Cycle Trigger Mode = External Edge or External Level. Symbol Data Output = Enabled globally and for EtherNet/IP. When to Output = As Soon As Possible. End of Read Cycle = Timeout. No Read message = Enabled.
QX Hawk Industrial Imager User Manual
A-105
Page 422
Using EtherNet/IP
NET and MOD LED Indicators MOD (Module) Indicator State
Summary
Steady OFF
No power
Steady GREEN
Device operational
Steady RED
Major fault
Flashing GREEN / Self-test RED
Requirement If no power is supplied to the device, the module status indicator will be steady OFF. If the device is operating correctly, the module status indicator will be steady GREEN. If the device has detected a non-recoverable minor fault, the module status indicator will be steady RED. While the device is performing its power-up testing, the module status indicator will be flashing GREEN / RED.
Microscan Implementation Per requirement Per requirement Safe Mode: Basic comm. only. Scanning system non-functional. Per requirement.
NET (Network) Microscan Implementation No power, no Per requirement. If the device does not have an IP device has IP address Steady OFF address (or is powered off), the network Before acquired an IP status indicator will be steady OFF. address via DHCP. requirement. If the device has no established connections, Per After device has but has obtained an IP address, the Flashing GREEN No connections network status indicator will be flashing acquired an IP address (static or GREEN. DHCP). If the device has at least one established connection (even to the Message Steady GREEN Connected Router), the network status indicator will Per requirement. be steady GREEN. Connection If one or more of the connections in which the device is the target has timed Per requirement. timeout Flashing RED out, the network status indicator will be flashing RED. If the device has detected that its IP Steady RED Duplicate IP address is already in use, the network Not implemented. status indicator will be steady RED. While the device is performing its Flashing GREEN / Self-test power-up testing, the module status Per requirement. RED indicator will be flashing GREEN / RED. Indicator State
A-106
Summary
Requirement
QX Hawk Industrial Imager User Manual
Page 423
Appendices
Appendix J, Allen-Bradley Version 16 PLC Setup This section was created and run on the following Allen Bradley/Rockwell components: • RSLogix 5000 Version 16 • ControlLogix 5561 processor • 756-ENBT/A EtherNet/IP interface card, firmware version 4.003 or newer. This setup procedure was also followed in RSLogix with a CompactLogix 5332E as the processor, though the final program was not tested with a CompactLogix processor. 1. Create the I/O Configuration for the base system, including the system’s Ethernet interface:
QX Hawk Industrial Imager User Manual
A-107
Page 424
Allen-Bradley Version 16 PLC Setup 2. Add QX Hawk by right-clicking on the Ethernet interface, and select “New Module”:
3. Select “ETHERNET-MODULE Generic Ethernet Module”, and click OK:
A-108
QX Hawk Industrial Imager User Manual
Page 425
Appendices 4. Configure the following fields: “Name” = A useful name to remember the unit “IP Address” = The IP Address of QX Hawk “Comm Format” = “Data – DINT” “Input” “Assembly Instance” = Choose either 100 (Small) or 101 (Big) “Input” “Size” = 21 (Small), or 44 (Big) “Output” “Assembly Instance” = 198 “Output” “Size” = 3 “Configuration” “Assembly Instance” = 1 “Configuration” “Size” = 0 (none) 5. Click OK when done. Example: For Small IN (Instance 100, Size 21):
QX Hawk Industrial Imager User Manual
A-109
Page 426
Allen-Bradley Version 16 PLC Setup Example: For Big IN (Instance 101, Size 44):
6. Configure the “Required Packet Interval (RPI)” and click OK. 20 ms or slower is strongly recommended. 10 ms is the minimum allowed by QX Hawk:
A-110
QX Hawk Industrial Imager User Manual
Page 427
Appendices 7. Double-click on the “Controller Tags” item, and verify QX Hawk’s :I and :O tags appear in the Controller Tags window:
8. Open the “Main Routine”:
QX Hawk Industrial Imager User Manual
A-111
Page 428
Allen-Bradley Version 16 PLC Setup 9. Right-click on the top rung and select “Import Rung”:
10. Click the Attachments icon in this PDF to show the 32-000001-xx.L5X file. Save the file to the location of your choice. Navigate to the file and click Import.
Click the icon at left in this PDF to display attached files. Right-click the 32-000001-xx.L5X file and select Save Attachment.
After you have saved the 32-000001-xx.L5X file, navigate to it and click Import in the Import Rung dialog.
A-112
QX Hawk Industrial Imager User Manual
Page 429
Appendices 11. At the “Import Configuration” window, link the first two items to the module name assigned earlier:
12. Link “:I” to the input assembly:
QX Hawk Industrial Imager User Manual
A-113
Page 430
Allen-Bradley Version 16 PLC Setup 13. Link “:O” to the output assembly:
14. Delete any empty rungs:
A-114
QX Hawk Industrial Imager User Manual