Page 361
Appendices
Symbologies Composite Aztec Micro QR Code Postal Symbologies Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 DataBar-14 (GS1 DataBar) DataBar Limited (GS1 DataBar) DataBar Expanded (GS1 DataBar) MicroPDF417
<K453,symbology status,separator status,separator> <K458,status> <K459,status> <K460,postal type,POSTNET status,PLANET status,USPS4CB status,POSTNET allow B and B’ fields,Australia Post Allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status, separator character,supplemental type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN 128 status,output format,application record separator status, application record separator character,application record brackets, application record padding> <K475,status,fixed symbol length status,fixed symbol length> <K476,status,unused,fixed symbol length status,fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value,background> <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status, ECC 130 status> <K480,status> <K481,status,check character output status,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,unused,fixed length status,fixed symbol length>
Composite Symbology Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-45
Page 362
Serial Commands Separator (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character
Code 39 Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 1 = Enabled Options: 0 = Disabled 1 = Enabled Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:
A-46
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
Page 363
Appendices Fixed Symbol Length (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 128
Full ASCII Set (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Codabar Status (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Start/Stop Match (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Start/Stop Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-47
Page 364
Serial Commands Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128
Check Character Type (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)
Check Character Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Interleaved 2 of 5 Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options: A-48
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled QX Hawk Industrial Imager User Manual
Page 365
Appendices Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128
Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128
Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
UPC/EAN UPC Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-49
Page 366
Serial Commands EAN Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled
Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Separator Character (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character
Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only
Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:
A-50
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
Page 367
Appendices
Code 128 / EAN 128 Status (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128
EAN 128 Status (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required
Output Format (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application
QX Hawk Industrial Imager User Manual
A-51
Page 368
Serial Commands Application Record Separator Status (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Separator Character (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character
Application Record Brackets (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Padding (Code 128 / EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Separation Factor (Code 128 / EAN 128) Serial Cmd:
Default: Options:
A-52
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest
QX Hawk Industrial Imager User Manual
Page 369
Appendices
Code 93 Status (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 3 = Both Standard and Edge-to-Edge Options: 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge Fixed Symbol Length Status (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Symbol Length (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 10 Options: 1 to 128
PDF417 Status (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length Status (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 10 Options: 1 to 2710 Decode at End of Read Cycle (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-53
Page 370
Serial Commands
Pharmacode Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 10 Options: 1 to 16 Minimum Bars (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 4 Options: 1 to 16 Bar Width Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Mixed Options: 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold Direction (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Forward Options: 0 = Forward 1 = Reverse Fixed Threshold Value (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 400 Options: 1 to 65535 A-54
QX Hawk Industrial Imager User Manual