Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 37 of 46

QX Hawk Industrial Imager User Manual, pages 361 to 370

Pages 361 to 370 of 460

The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan QX Hawk 6801

Page 361

Appendices

Symbologies Composite Aztec Micro QR Code Postal Symbologies Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 DataBar-14 (GS1 DataBar) DataBar Limited (GS1 DataBar) DataBar Expanded (GS1 DataBar) MicroPDF417

<K453,symbology status,separator status,separator> <K458,status> <K459,status> <K460,postal type,POSTNET status,PLANET status,USPS4CB status,POSTNET allow B and B’ fields,Australia Post Allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status, separator character,supplemental type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN 128 status,output format,application record separator status, application record separator character,application record brackets, application record padding> <K475,status,fixed symbol length status,fixed symbol length> <K476,status,unused,fixed symbol length status,fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value,background> <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status, ECC 130 status> <K480,status> <K481,status,check character output status,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,unused,fixed length status,fixed symbol length>

Composite Symbology Status (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required

Separator Status (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

A-45

Page 362

Serial Commands Separator (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character

Code 39 Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 1 = Enabled Options: 0 = Disabled 1 = Enabled Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:

A-46

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

Page 363

Appendices Fixed Symbol Length (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 128

Full ASCII Set (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Codabar Status (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Start/Stop Match (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled

Start/Stop Output (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled

Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

A-47

Page 364

Serial Commands Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128

Check Character Type (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)

Check Character Output (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Interleaved 2 of 5 Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled

Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options: A-48

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled QX Hawk Industrial Imager User Manual

Page 365

Appendices Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128

Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128

Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled

UPC/EAN UPC Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

A-49

Page 366

Serial Commands EAN Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled

Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required

Separator Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

Separator Character (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character

Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only

Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:

A-50

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

Page 367

Appendices

Code 128 / EAN 128 Status (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128

EAN 128 Status (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required

Output Format (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application

QX Hawk Industrial Imager User Manual

A-51

Page 368

Serial Commands Application Record Separator Status (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Application Record Separator Character (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character

Application Record Brackets (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Application Record Padding (Code 128 / EAN 128) Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled

Separation Factor (Code 128 / EAN 128) Serial Cmd:

Default: Options:

A-52

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest

QX Hawk Industrial Imager User Manual

Page 369

Appendices

Code 93 Status (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 3 = Both Standard and Edge-to-Edge Options: 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge Fixed Symbol Length Status (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Symbol Length (Code 93) Serial Cmd: <K475,status,fixed symbol length status,symbol length> Default: 10 Options: 1 to 128

PDF417 Status (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length Status (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 10 Options: 1 to 2710 Decode at End of Read Cycle (PDF417) Serial Cmd: <K476,status,unused,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

A-53

Page 370

Serial Commands

Pharmacode Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Fixed Symbol Length (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 10 Options: 1 to 16 Minimum Bars (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 4 Options: 1 to 16 Bar Width Status (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Mixed Options: 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold Direction (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 0 = Forward Options: 0 = Forward 1 = Reverse Fixed Threshold Value (Pharmacode) Serial Cmd: <K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> Default: 400 Options: 1 to 65535 A-54

QX Hawk Industrial Imager User Manual