The text of a manual · part 36 of 46
QX Hawk Industrial Imager User Manual, pages 351 to 360
Pages 351 to 360 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 351
Appendices
RS-422 Data Type Symbol Data Output (RS-422 Data Type) Serial Cmd: Default: Options:
<K132,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Extended Data (RS-422 Data Type) Serial Cmd: Default: Options:
<K132,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Diagnostic Output (RS-422 Data Type) Serial Cmd: Default: Options:
<K132,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
External Source Processing Mode (RS-422 Data Type) Serial Cmd: Default: Options:
<K132,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data
Ethernet TCP Port 1 Data Type Symbol Data Output (Ethernet TCP Port 1 Data Type) Serial Cmd: Default: Options:
<K133,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Extended Data (Ethernet TCP Port 1 Data Type) Serial Cmd: Default: Options:
<K133,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-35
Page 352
Serial Commands Diagnostic Output (Ethernet TCP Port 1 Data Type) Serial Cmd: Default: Options:
<K133,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
External Source Processing Mode (Ethernet TCP Port 1 Data Type) Serial Cmd: Default: Options:
<K133,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data
Ethernet TCP Port 2 Data Type Symbol Data Output (Ethernet TCP Port 2 Data Type) Serial Cmd: Default: Options:
<K134,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Extended Data (Ethernet TCP Port 2 Data Type) Serial Cmd: Default: Options:
<K134,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
Diagnostic Output (Ethernet TCP Port 2 Data Type) Serial Cmd: Default: Options:
<K134,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled
External Source Processing Mode (Ethernet TCP Port 2 Data Type) Serial Cmd: Default: Options:
<K134,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data
Preamble Status (Preamble) Serial Cmd: Default: Options: A-36
<K141,status,preamble character(s)> 0 = Disabled 0 = Disabled 1 = Enabled QX Hawk Industrial Imager User Manual
Page 353
Appendices Preamble Characters (Preamble) Serial Cmd: Default: Options:
<K141,status,preamble character(s)> CR (0x0D) 1 – 4 ASCII characters
Postamble Status (Postamble) Serial Cmd: Default: Options:
<K142,status,postamble character(s)> 1 = Enabled 0 = Disabled 1 = Enabled
Postamble Characters (Postamble) Serial Cmd: Default: Options:
<K142,status,postamble character(s)> CR LF (0x0D 0x0A) 1 – 4 ASCII characters
Response Timeout Serial Cmd: Default: Options:
<K143,response timeout> 5 (x10 ms = 50) 0 to 255 (x10 ms)
LRC Status Serial Cmd: Default: Options:
<K145,status> 0 = Disabled 0 = Disabled
1 = Enabled
ACK/NAK Options Serial Cmd:
<K147,RES,REQ,STX,ETX,ACK,NAK>
RES,REQ,STX,ETX,ACK,NAK Defaults (ACK/NAK Options) RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)
QX Hawk Industrial Imager User Manual
00 (disabled) 00 (disabled) 00 (disabled) 00 (disabled) 06 15
A-37
Page 354
Serial Commands
Polling Mode Options Serial Cmd:
<K148,RES,REQ,STX,ETX,ACK,NAK>
RES,REQ,STX,ETX,ACK,NAK Defaults (Polling Mode Options) RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)
04 05 02 03 06 15
Autoconfiguration Daisy Chain Serial Cmd:
<K150DAISY>
ASCII Character Entry Modifier Commands that require ASCII text fields, such as Preamble and Postamble commands, can be sent to the imager as hex pairs (see Appendix G, ASCII Table, for conversions). Serial Cmd Format: <Knnnh,00-FF> To enter ASCII fields as hex values (00 to FF), add a lower-case h directly after the command’s K number, and then enter the hex value that corresponds with the desired ASCII character. Example: Serial Cmd:
<K142,status,postamble character(s)>
The ASCII characters <, >, and , can only be entered as hex pairs. So, to make > the postamble in the symbol decode output, enter the Postamble command as follows: <K142h,,3E> Note that the “status” field contains only a , . This is because the only field that is being changed is the “postamble character(s)” field. (See Serial Configuration Command Conventions for a more detailed explanation of this command shortcut.)
Protocol Selection Protocol (Protocol Selection) Serial Cmd: Options:
A-38
<K160,protocol,address,protocol port> 0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS and XON/XOFF 4 = ACK/NAK 5 = Polling Mode
QX Hawk Industrial Imager User Manual
Page 355
Appendices Address (Protocol Selection) Serial Cmd: Default: Options:
<K160,protocol,address,protocol port> 1 1 – 50 1 = Poll address 0x1C, select address 0x1D 2 = Poll address 0x1E, select address 0x1F ... 50 = Poll address 0x7E, select address 0x7F
Protocol Port (Protocol Selection) Serial Cmd: Default: Options:
<K160,protocol,address,protocol port> 0 0–1 0 = Main RS-232 on QX Hawk Connector A 1 = RS-422/485 on QX Hawk Connector B
External Data Routing Mode (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Transparent 2 = Half Duplex 3 = Full Duplex 4 = Customized
Destination Port (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = RS-232 on QX Hawk Connector A 0 = RS-232 on QX Hawk Connector A 1 = RS-232 on QX Hawk Connector B 2 = RS-422 on QX Hawk Connector B 4 = Ethernet TCP Port 1 5 = Ethernet TCP Port 2 6 = EtherNet/IP
QX Hawk Industrial Imager User Manual
A-39
Page 356
Serial Commands Ambles to Source (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled
Echo to Source (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled
Output at End of Read Cycle (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 0 = Disabled 0 = Disabled 1 = Enabled
Output at ETX (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> CR (0x0D) Any 7-bit ASCII character
Output at Timeout (External Data Routing) Serial Cmd: Default: Options:
<K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> 200 (x10 ms = 2 seconds) 0 – 65535
Array Communication Modes Mode (Array Communication Modes) Serial Cmd: Default: Options:
A-40
<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 0 = Disabled 0 = Disabled 1 = Daisy Chain
QX Hawk Industrial Imager User Manual
Page 357
Appendices Source (Array Communication Modes) Serial Cmd: Default: Options:
<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 1 = RS-232 on QX Hawk Connector B 0 = RS-232 on QX Hawk Connector A 1 = RS-232 on QX Hawk Connector B 2 = RS-422 on QX Hawk Connector B 4 = Ethernet TCP Port 1 5 = Ethernet TCP Port 2
Daisy Chain ID Status (Array Communication Modes) Serial Cmd: Default: Options:
<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 0 = Disabled 0 = Disabled 1 = Enabled
Daisy Chain ID (Array Communication Modes) Serial Cmd: Default: Options:
<K162,mode,source,daisy chain i.d. status,daisy chain i.d.> 1/ One or two ASCII characters.
QX Hawk Industrial Imager User Manual
A-41
Page 358
Serial Commands
Read Cycle Trigger Mode / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character Serial Trigger Stop Character Capture Mode Capture Time Store No Read Image Image Processing Timeout Number of Symbols in Field of View
<K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,number before output> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,mode,number of captures,rapid capture mode> <K242,time before first capture,time between 1-2,time between 2-3,time between 3-4,time between 4-5,time between 5-6,time between 6-7,time between 7-8> <K244,image storage type,image storage mode> <K245,image processing timeout> <K518,number of symbols in field of view>
Trigger Mode / Filter Duration Trigger Mode (Trigger Mode / Filter Duration) Serial Cmd: Default: Options:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 0 = Continuous Read 0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and Edge
Leading Edge Trigger Filter (Trigger Mode / Filter Duration) Serial Cmd: Default: Options:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (x 32.0 µs)
Trailing Edge Trigger Filter (Trigger Mode / Filter Duration) Serial Cmd: Default: Options:
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter> 313 (~10 ms) 1 to 65535 (x 32.0 µs)
Serial Trigger Character (Delimited) Serial Cmd: Default: Options: A-42
<K201,serial trigger character> Space (0x20) Any 7-bit ASCII character QX Hawk Industrial Imager User Manual
Page 359
Appendices
External Trigger State Serial Cmd: Default: Options:
<K202,active state> 1 = Positive 0 = Negative
1 = Positive
End of Read Cycle End of Read Cycle Mode (End of Read Cycle) Serial Cmd: Default: Options:
<K220,end of read cycle mode,read cycle timeout> 0 = Timeout 0 = Timeout 1 = New Trigger 2 = Timeout or New Trigger 3 = Last Frame 4 = Last Frame or New Trigger
Read Cycle Timeout (End of Read Cycle) Serial Cmd: Default: Options:
<K220,end of read cycle,read cycle timeout> 100 (x10 ms = 1 second) 1 to 65535
Decodes Before Output Serial Cmd: Default: Options:
<K221,decodes before output,mode> 1 1 to 255
Mode (Decodes Before Output) Serial Cmd: Default: Options:
<K221,decodes before output,mode> 0 = Non-Consecutive 0 = Non-Consecutive 1 = Consecutive
Multisymbol Number of Symbols (Multisymbol) Serial Cmd: <K222,number of symbols,multisymbol separator> Default: 1 Options: 1 to 100 Multisymbol Separator (Multisymbol) Serial Cmd: <K222,number of symbols,multisymbol separator> Default: , (comma) Options: Any 7-bit ASCII character
QX Hawk Industrial Imager User Manual
A-43
Page 360
Serial Commands
Serial Trigger Start Character (Non-Delimited) Serial Cmd: Default: Options:
<K229,start character> NULL (0x00) Two hex digits representing any ASCII character except <, >, XON, and XOFF.
Serial Trigger Stop Character (Non-Delimited) Serial Cmd: Default: Options:
<K230,stop character> NULL (0x00) Two hex digits representing any ASCII character except <, >, XON, and XOFF.
Image Processing Timeout Serial Cmd: Default: Options:
A-44
<K245,processing timeout> 200 (0.2 seconds) 1 to 65535
QX Hawk Industrial Imager User Manual