Page 341

Appendices I/O Parameters <K529,gain,shutter speed,focus position,symbol type,window of interest framing,window of interest margin,unused> <K701,serial command echo status,serial command beep status, Serial Verification control/hex output> Beeper <K702,status> Quality Output <K704,quality output separator,decodes per trigger status> Symbol Data Output <K705,symbol data output status,when to output symbol data> Read Duration Output <K706,status,separator> No Read Message <K714,status,message> Input 1 <K730,mode,active state> Frame Information <K734,output frame number,output coordinates> ISO/IEC 16022 Parameter LED Configuration <K737,unused,ISO/IEC 16022 parameter> Green Flash LED <K750,green flash LED status,targeting status,green flash duration> Status Indicators <K751,comm,bar graph,I/O 1,I/O 2> <K757,status,comm port,image mode,image format,JPEG quality, EZ Trax Output object info output,grade output> Database Identifier Output <K759,status,separator character> <K770,global status,default on power-on,load configuration database, EZ Button save for power-on> EZ Button Modes <K771,single beep,two beeps,three beeps,four beeps> <K780,trend analysis mode,number of triggers,number to output Trend Analysis Output 1 on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output Trend Analysis Output 2 on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output Trend Analysis Output 3 on,decodes per trigger> Diagnostics Output 1 <K790,unused,service unit> Diagnostics Output 2 <K791,unused,service unit> Diagnostics Output 3 <K792,unused,service unit> <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 1 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> <K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 2 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> <K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 3 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Output 1 Parameters <K810,output on,output state,pulse width,output mode> Output 2 Parameters <K811,output on,output state,pulse width,output mode> Output 3 Parameters <K812,output on,output state,pulse width,output mode> Calibration Options

QX Hawk Industrial Imager User Manual

A-25

Page 342

Serial Commands Symbol Quality Global Symbol Quality Output Data Matrix ISO/IEC 16022 Parameters Data Matrix Grading

<K708,quality output separator,output mode> <K709,symbol contrast,print growth,axial non-uniformity,unused ECC> <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle>

Matchcode Matchcode Master Symbol Database Size New Master Pin Un-Delimited Serial Start Character Un-Delimited Serial Stop Character Master Symbol Match Replace Mismatch Replace Diagnostics Time Since Reset (Read-only) Service Message User-Defined Name Camera Setup Window of Interest Focus Distance Illumination (Standard QX Hawk Only) Camera Settings Sub-Sampling Morphological Pre-Processing Morphological Operations External Illumination Mode Configuration Database Number of Active Indexes Configuration Database (CMOS) Configuration Database (CCD)

<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K229,start character value> <K230,stop character value> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string> <K407,hours,minutes> (returns: hours,minutes) <K409,status,service message,threshold,resolution> <K412,user-defined name> <K516,row pointer,column pointer,row depth,column width> <K525,focal distance,distance units,lens type> <K539,mode,intensity> <K541,shutter speed,gain> <K542,sub-sampling> <K550,status> <K551,unused,operation,size> <K553,mode> <K252,number of active indexes,sort database> <K255,index,shutter speed,gain,focal distance,sub-sampling,row pointer,column pointer,row depth,column width,symbol type,morphology operation,morphology size> <K255,index,shutter speed,gain,focal distance,unused,row pointer, column pointer,row depth,column width,symbol type,morphology operation,morphology size>

Save Current Settings to Configuration <K255+,index> Database Load Current Settings from Configuration <K255–,index> Database Request Database Index Setting <K255?,index> Request All Database Settings <K255?> <K256,switch mode,frame count/time,image process looping, Database Mode image dimensions>

A-26

QX Hawk Industrial Imager User Manual

Page 343

Appendices Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Number of Filters

QX Hawk Industrial Imager User Manual

<K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology type,length,wildcard,placeholder, data,unused,database index> <K745,number of filters>

A-27

Page 344

Serial Commands

Serial Command Format Microscan readers are controlled by two types of serial commands: configuration commands and utility commands.

Rules that apply to both configuration and utility commands • Less than ‘<‘ and greater than ‘>’ angle bracket characters enclose the commands. • Commands and data are case sensitive. Characters must be entered as upper or lower case, as specified.

Serial Utility Commands Serial Utility Commands are sent during operations and are not followed by <A> or <Z>.

Serial Configuration Commands (K Commands) Microscan’s serial configuration commands begin with a single “K” character followed by a 3-digit numeric character, comma-separated command fields, and an initializing command, as follows: <Knumeric character,data,data,...etc.><initializing command> An initializing command <Z> or <A> may follow the command. • <Z> initializes the imager’s memory and saves for power-on. • <A> initializes the imager’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K473,1><Z>. To change Baud Rate and reset without saving changes for power-on, send <K100,3><A>.

Serial Configuration Command Conventions • All command fields (except the last) must be followed by a comma (without a space). • NULL cannot be used. The characters <, >, and , can be used, but only if entered as hex pairs (see ASCII Character Entry Modifier). • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <K100,4,1,0,0> can be entered as <K100,,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate only, send <K100,3>.

Concatenating Configuration Commands Commands can be concatenated (added together) in a single string. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Quiet Zone, and resets the data buffers without saving the changes for power-on. A-28

QX Hawk Industrial Imager User Manual

Page 345

Appendices

Serial Command Status Request To ensure that any command was received and accepted, send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.

Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>

QX Hawk Industrial Imager User Manual

A-29

Page 346

Serial Commands

Serial Configuration Commands The following serial commands can be entered through ESP’s Terminal to control QX Hawk functions. Detailed descriptions of command parameters are available in Parameters.

Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports Search and Configure Mode EtherNet/IP RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type EtherNet/IP Port 1 Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes

<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K128,ESP Search and Configure Mode> <K129,status> <K130,symbol data output,extended data,diagnostic output, external source processing mode> <K131,symbol data output,extended data,diagnostic output, external source processing mode> <K132,symbol data output,extended data,diagnostic output, external source processing mode> <K133,symbol data output,extended data,diagnostic output, external source processing mode> <K134,symbol data output,extended data,diagnostic output, external source processing mode> <K136,symbol data output,extended data,diagnostic output, external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.>

RS-232 A Baud Rate (RS-232 A) Serial Cmd: Default: Options:

A-30

<K100,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 3 = 4800 4 = 9600 6 = 38.4K 7 = 57.6K 9 = 230K

2 = 2400 5 = 19.2K 8 = 115.2K

QX Hawk Industrial Imager User Manual

Page 347

Appendices Parity (RS-232 A) Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even

2 = Odd

Stop Bits (RS-232 A) Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

Data Bits (RS-232 A) Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

RS-232 B Status (RS-232 B) Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 1 = Enabled 0 = Disabled 1 = Enabled

Baud Rate (RS-232 B) Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K

Parity (RS-232 B) Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd

Stop Bits (RS-232 B) Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

QX Hawk Industrial Imager User Manual

A-31

Page 348

Serial Commands Data Bits (RS-232 B) Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

RS-422 Status (RS-422) Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = Disabled 0 = Disabled 1 = Enabled

Baud Rate (RS-422) Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K

Parity (RS-422) Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd

Stop Bits (RS-422) Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

Data Bits (RS-422) Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

Ethernet Status (Ethernet) Serial Cmd: Default: Options:

A-32

<K126,status,IP address,subnet,gateway,IP address mode> 1 = Enabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

Page 349

Appendices IP Address (Ethernet) Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 192.168.0.100 0.0.0.0 – 255.255.255.255

Subnet (Ethernet) Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 255.255.0.0 0.0.0.0 – 255.255.255.255

Gateway (Ethernet) Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 0.0.0.0 0.0.0.0 – 255.255.255.255

IP Address Mode (Ethernet) Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 0 = Static 0 = Static 1 = DHCP

Ethernet TCP Ports TCP Port 1 (Ethernet TCP Ports) Serial Cmd: Default: Options:

<K127,TCP Port 1,TCP Port 2> 2001 1024 – 65535

TCP Port 2 (Ethernet TCP Ports) Serial Cmd: Default: Options:

<K127,TCP Port 1,TCP Port 2> 2003 1024 – 65535

RS-232 A Data Type Symbol Data Output (RS-232 A Data Type) Serial Cmd: Default: Options:

<K130,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

QX Hawk Industrial Imager User Manual

A-33

Page 350

Serial Commands Extended Data (RS-232 A Data Type) Serial Cmd: Default: Options:

<K130,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output (RS-232 A Data Type) Serial Cmd: Default: Options:

<K130,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode (RS-232 A Data Type) Serial Cmd: Default: Options:

<K130,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

RS-232 B Data Type Symbol Data Output (RS-232 B Data Type) Serial Cmd: Default: Options:

<K131,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extended Data (RS-232 B Data Type) Serial Cmd: Default: Options:

<K131,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output (RS-232 B Data Type) Serial Cmd: Default: Options:

<K131,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode (RS-232 B Data Type) Serial Cmd: Default: Options: A-34

<K131,symbol data output,extended data,diagnostic output,external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data QX Hawk Industrial Imager User Manual