The text of a manual · part 34 of 46
QX Hawk Industrial Imager User Manual, pages 331 to 340
Pages 331 to 340 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 331
PNP Output for Host Input
Camera
Oo t 1 gOutpu
Appendices
Host
+V
Input aA goutput 2
I JOutput 3 fi, >
Output Common
> Input
Input o - >
QX Hawk Industrial Imager User Manual o:
A-15
Page 332
Electrical Specifications
PNP Output for External Load
Camera
SS
Output 1 + tp, - =>
Output 2 + tp
Load
Output 3
Load, Common
Load
A-16
QX Hawk Industrial Imager User Manual
Page 333
Appendices
Optoisolated Inputs All discrete inputs are optoisolated. Inputs can be configured as either NPN or PNP, but NPN and PNP cannot be mixed in a system, because the input common is shared by all inputs.
NPN
QX Hawk Industrial Imager User Manual
A-17
Page 334
Electrical Specifications
P N Pp PNP Source
Camera
= + I cLo ] | Trigger :
, New Master a CLC q 5
Input 1 va 4 cLc, | Input Common |. GND
4 »!| Lad | le ™ o - w - e
CLC = Current Limiting Circuit
A-18 QX Hawk Industrial Imager User Manual
Page 335
Output Wiring M12 12-pin plug flying lead cordset om Sai 2 Output 1 Pin 5 Gray e Output 2. Pin 11, - - - - - - - - -. Grray/Pink ® Output 3 Pin 6 Pink 2 24V+ Pin 2, - - - - - - - - oo Input Common Pin 8, - - - - - - - - Red New Master Pin 4, - - - - - - - - Yellow 2s
Output Common Pin 12, - - - - - - - 4 Ground Pin 7, - - - - - - - Blue
QX Hawk Industrial Imager User Manual
Appendices
Light Stack
Red Beacon Amber Beacon Green Beacon
24V+
Push Button
Normally Open - Momentary (New Master)
A-19
Page 336
Appendices
Appendix C, Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
An earth ground is provided through the cable shields and chassis of the scanner.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, scanner, and their power supplies are connected to a common earth ground.
Grounding and Isolation Important: Mounting a QX Hawk to grounded conductive material may cause communication problems or unreliable operation. If you need to mount the reader to a bracket or plate, be sure that a proper ground connection is available. If not, electrical isolation of the reader should be performed. Using Microscan’s Isolation Mounting Kit, P/N 98-9000038-01, will ensure that no ground loop or other external electrical noise can occur through the reader.
QX Hawk Industrial Imager User Manual
A-20
Page 337
Appendices
Expected Power and Ground Connections for Proper Operation
Notes: • Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”. • Supply “Return” and “Earth” ground must be stable, low-impedance reference points. • “2-Terminal Power Supply” must still provide an “Earth” connection to the imager.
QX Hawk Industrial Imager User Manual
A-21
Page 338
Flying Lead Cordset Pinouts
Appendix D, Flying Lead Cordset Pinouts Microscan offers two flying lead cordsets for use in QX Hawk configurations: • 61-000166-02 (Plug, Screw-On version) • 61-000167-02 (Socket, Screw-On version) The diagrams below show the correspondence of wire colors to pins.
61-000166-02 – M12 12-Pin Plug to Flying Leads 61-000166-02 connects to QX Hawk Connector B (serial) and QX-1 Connector 2.
61-000167-02 – M12 12-Pin Socket to Flying Leads 61-000167-02 connects to QX Hawk Connector A and QX-1 Connectors 1 and 3.
A-22
QX Hawk Industrial Imager User Manual
Page 339
Appendices
Appendix E, Serial Commands Note: For a list of utility commands such as defaults, read rate requests, device control options, and imager status requests, see Serial Utility Commands. Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports Search and Configure Mode EtherNet/IP RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type EtherNet/IP Port 1 Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes Read Cycle Trigger Mode / Trigger Filter Duration Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Multisymbol Serial Trigger Start Character QX Hawk Industrial Imager User Manual
<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K128,ESP Search and Configure Mode> <K129,status> <K130,symbol data output,extended data,diagnostic output, external source processing mode> <K131,symbol data output,extended data,diagnostic output, external source processing mode> <K132,symbol data output,extended data,diagnostic output, external source processing mode> <K133,symbol data output,extended data,diagnostic output, external source processing mode> <K134,symbol data output,extended data,diagnostic output, external source processing mode> <K136,symbol data output,extended data,diagnostic output, external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.> <K200,trigger mode,leading edge trigger filter duration,trailing edge trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,mode,read cycle timeout> <K221,number before output> <K222,number of symbols,multisymbol separator> <K229,start character>
A-23
Page 340
Serial Commands Serial Trigger Stop Character Capture Mode Capture Time Store No Read Image Image Processing Timeout Number of Symbols in Field of View Symbologies Composite Aztec Micro QR Code Postal Symbologies Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 DataBar-14 (GS1 DataBar) DataBar Limited (GS1 DataBar) DataBar Expanded (GS1 DataBar) MicroPDF417
A-24
<K230,stop character> <K241,mode,number of captures,rapid capture mode> <K242,time before first capture,time between 1-2,time between 2-3,time between 3-4,time between 4-5,time between 5-6,time between 6-7,time between 7-8> <K244,image storage type,image storage mode> <K245,image processing timeout> <K518,number of symbols in field of view> <K453,symbology status,separator status,separator> <K458,status> <K459,status> <K460,postal type,POSTNET status,PLANET status,USPS4CB status,POSTNET allow B and B’ fields,Australia Post Allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status, separator character,supplemental type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN 128 status,output format,application record separator status, application record separator character,application record brackets, application record padding> <K475,status,fixed symbol length status,fixed symbol length> <K476,status,unused,fixed symbol length status,fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value,background> <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status, ECC 130 status> <K480,status> <K481,status,check character output status,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,unused,fixed length status,fixed symbol length>
QX Hawk Industrial Imager User Manual