The text of a manual · part 38 of 46
QX Hawk Industrial Imager User Manual, pages 371 to 380
Pages 371 to 380 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 371
Appendices
DataBar-14 (GS1 DataBar) Serial Cmd: Default: Options:
<K482,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Limited (GS1 DataBar) Serial Cmd: Default: Options:
<K483,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Expanded (GS1 DataBar) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (DataBar Expanded; GS1 DataBar) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (DataBar Expanded; GS1 DataBar) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74
MicroPDF417 Serial Cmd: Default: Options:
<K485,status,unused,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (MicroPDF417) Serial Cmd: Options:
<K485,status,fixed symbol length status,fixed symbol length> 1 to 366
QX Hawk Industrial Imager User Manual
A-55
Page 372
Serial Commands
I/O Parameters <K529,gain,shutter speed,focus position,symbol type,window of interest framing,window of interest margin,unused> <K701,serial command echo status,serial command beep status, Serial Verification control/hex output> Beeper <K702,status> Quality Output <K704,quality output separator,decodes per trigger status> Symbol Data Output <K705,symbol data output status,when to output symbol data> Read Duration Output <K706,status,separator> No Read Message <K714,status,message> Input 1 <K730,mode,active state> Frame Information <K734,output frame number,output coordinates> ISO/IEC 16022 Parameter LED Configuration <K737,unused,ISO/IEC 16022 parameter> Green Flash LED <K750,green flash LED status,targeting status,green flash duration> Status Indicators <K751,comm,bar graph,I/O 1,I/O 2> <K757,status,comm port,image mode,image format,JPEG quality, EZ Trax Output object info output,grade output> Database Identifier Output <K759,status,separator character> <K770,global status,default on power-on,load configuration database, EZ Button save for power-on> EZ Button Modes <K771,single beep,two beeps,three beeps,four beeps> <K780,trend analysis mode,number of triggers,number to output Trend Analysis Output 1 on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output Trend Analysis Output 2 on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output Trend Analysis Output 3 on,decodes per trigger> Diagnostics Output 1 <K790,unused,service unit> Diagnostics Output 2 <K791,unused,service unit> Diagnostics Output 3 <K792,unused,service unit> <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 1 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> <K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 2 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> <K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, Symbol Quality Output 3 axial non-uniformity threshold,output on unused ECC,unused ECC threshold> Output 1 Parameters <K810,output on,output state,pulse width,output mode> Output 2 Parameters <K811,output on,output state,pulse width,output mode> Output 3 Parameters <K812,output on,output state,pulse width,output mode> Calibration Options
A-56
QX Hawk Industrial Imager User Manual
Page 373
Appendices
Serial Verification Serial Command Echo Status (Serial Verification) Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status (Serial Verification) Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Control/Hex Output (Serial Verification) Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status,control/hex output> 0 = Control 0 = Control 1 = Hex
Beeper Serial Cmd: Default: Options:
<K702,beeper status> 1 = Good Read 0 = Disabled 1 = Good Read
2 = No Read
Quality Output Separator (Quality Output) Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> , (comma) Any 7-bit ASCII character
Decodes per Trigger Status (Quality Output) Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> 0 = Disabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
A-57
Page 374
Serial Commands
Symbol Data Output Symbol Data Output Status (Symbol Data Output) Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 3 = Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read
When to Output Symbol Data (Symbol Data Output) Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 0 = As Soon As Possible 0 = ASAP 1 = End of Read Cycle
Symbology ID Output Status (Symbol Data Output) Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology ID output status> 0 = Disabled 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID
Read Duration Output Read Duration Output Status (Read Duration Output) Serial Cmd: Default: Options:
<K706,status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
Read Duration Output Separator (Read Duration Output) Serial Cmd: Default: Options:
<K706,status,separator> Space (0x20) Any 7-bit ASCII character
No Read Message No Read Message Status (No Read Message) Serial Cmd: Default: Options:
<K714,No Read message status,No Read message> 1 = Enabled 0 = Disabled 1 = Enabled
No Read Message (No Read Message) Serial Cmd: Default: Options: A-58
<K714,no read message status,No Read message> NOREAD Any valid ASCII string up to 128 characters QX Hawk Industrial Imager User Manual
Page 375
Appendices
Input 1 Status (Input 1) Serial Cmd: <K730,status,active state> Default: 0 = Disabled Options: 0 = Disabled 1 = Reset Counts 2 = Unlatch Output Active State (Input 1) Serial Cmd: <K730,status,active state> Default: 0 = Active Open Options: 0 = Active Open 1 = Active Closed
Green Flash LED (Standard QX Hawk Only) Green Flash Mode (Green Flash LED) Serial Cmd: <K750,green flash mode,unused,green flash duration> Default: 1 = Good Read Options: 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe Green Flash Duration (Green Flash LED) Serial Cmd: <K750,green flash mode,unused,green flash duration> Default: 100 (1 second) Options: 0 to 65535 (in 10 ms increments)
Status Indicators Status (Status Indicators) Serial Cmd: <K751,status,bar graph,I/O 1,I/O 2> Default: 1 = PHY Activity Options: 0 = Disabled 1 = PHY Activity 2 = Protocol Activity Bar Graph (Status Indicators) Serial Cmd: <K751,status,bar graph,I/O 1,I/O 2> Default: 1 = Read Rate / Good Read Options: 0 = Disabled 1 = Read Rate / Good Read 2 = Symbol Grade QX Hawk Industrial Imager User Manual
A-59
Page 376
Serial Commands I/O 1 (Status Indicators) Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 1 = Output Active 0 = Disabled 1 = Output Active 2 = Input Active
I/O 2 (Status Indicators) Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 2 = Input Active 0 = Disabled 1 = Output Active 2 = Input Active
Database Identifier Output Status (Database Identifier Output) Serial Cmd: Default: Options:
<K759,status,separator> 0 = Disabed 0 = Disabled 1 = Enabled
Separator (Database Identifier Output) Serial Cmd: Default: Options:
<K759,status,separator> Space (0x20) Any 7-bit ASCII character
EZ Button Global Status (EZ Button) Serial Cmd: Default: Options:
<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch
Default on Power-On (EZ Button) Serial Cmd: Default: Options:
A-60
<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled
QX Hawk Industrial Imager User Manual
Page 377
Appendices
EZ Button Modes (Standard QX Hawk) Serial Cmd: Options:
<K771,one beep,two beeps,three beeps,four beeps> 0 = Disabled 1 = Enabled
One Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.
EZ Button Modes (QX Hawk C-Mount) Serial Cmd: Options:
<K771,one beep,two beeps,three beeps,four beeps> 0 = Disabled 1 = Enabled
One Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Unused 8 = Unused 9 = Bar Code Config.
Trend Analysis Output 1 Trend Analysis Mode (Trend Analysis Output 1) Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 1 = No Read 0 = Mismatch 1 = No Read 2 = Decodes per Trigger
QX Hawk Industrial Imager User Manual
A-61
Page 378
Serial Commands Trigger Evaluation Period (Trend Analysis Output 1) Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Number to Output On (Trend Analysis Output 1) Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Decodes per Trigger Threshold (Trend Analysis Output 1) Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 65535
Trend Analysis Output 2 Serial Cmd:
<K781,trend analysis mode,trigger evaluation period,number to output on>
Trend Analysis Output 3 Serial Cmd:
<K782,trend analysis mode,trigger evaluation period,number to output on>
Diagnostics Output 1 Service Unit (Diagnostics Output 1) Serial Cmd: Default: Options:
<K790,service unit> 0 = Disabled 0 = Disabled
1 = Enabled
Diagnostics Output 2 Serial Cmd:
<K791,service unit>
Diagnostics Output 3 Serial Cmd:
A-62
<K792,service unit>
QX Hawk Industrial Imager User Manual
Page 379
Appendices
Output 1 Parameters Output On (Output 1 Parameters) Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = Symbol Quality 6 = Diagnostic Warning 7 = In Read Cycle
Output State (Output 1 Parameters) Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Normally Open 0 = Normally Open 1 = Normally Closed
Pulse Width (Output 1 Parameters) Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 500 1 to 65535 (in 1 ms increments)
Output Mode (Output 1 Parameters) Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Pulse 0 = Pulse 1 = Latch Mode 1 (Unlatch Input 1 Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)
Output 2 Parameters Serial Cmd:
<K811,output on,output state,pulse width,output mode>
Output 3 Parameters Serial Cmd:
<K812,output on,output state,pulse width,output mode>
QX Hawk Industrial Imager User Manual
A-63
Page 380
Serial Commands
Matchcode Matchcode Master Symbol Database Size New Master Pin Un-Delimited Serial Start Character Un-Delimited Serial Stop Character Master Symbol Match Replace Mismatch Replace
<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K229,start character value> <K230,stop character value> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string>
Matchcode Matchcode Type (Matchcode) Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Wild Card 3 = Sequential
Sequential Matching (Matchcode) Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Increment 0 = Increment 1 = Decrement
Match Start Position (Matchcode) Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 0 to 3000
Match Length (Matchcode) Serial Cmd: Default: Options:
A-64
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 1 to 3000
QX Hawk Industrial Imager User Manual