Page 301

Utilities

Request Checksum Send a request to the imager for application code or DSP code checksums. 1. Click the Firmware tab. 2. Select App Code or DSP Code from the dropdown menu to the left of the Request Checksum button. 3. Click the Request Checksum button to see the part number displayed in the text field to the right.

Request Checksum by Serial Command • When <!> (Display All Available Firmware Checksums) is sent, the imager returns: <!a/APP_CHECKSUM><!d/DSP_CHECKSUM><!d/CFG_CHECKSUM>. • When <!a> (Display Application Firmware Checksum) is sent, the imager returns: <!a/APP_CHECKSUM>. • When <!d> (Display DSP Firmware Checksum) is sent, the imager returns: <!d/DSP_CHECKSUM>. • When <!p> (Display System Configuration File Checksum) is sent, the imager returns: <!d/CFG_CHECKSUM>.

QX Hawk Industrial Imager User Manual

7-19

Page 302

Firmware

Request Build Number by Serial Command Note: X = base part number; R = revision number; B = build number • When <#.> (Display All Firmware Build Numbers) is sent, the imager returns: <#a/35-XXXXXX-RR.BBB><#b/35-XXXXXX-RR.BBB><#d/35-XXXXXX-RR.BBB> <#k/35-XXXXXX-RR.BBB><#p/35-XXXXXX-RR.BBB>. • When <#a.> (Display Application Firmware Build Number) is sent, the imager returns: <#a/35-XXXXXX-RR.BBB>. • When <#b.> (Display Boot Firmware Build Number) is sent, the imager returns: <#b/35-XXXXXX-RR.BBB>. • When <#d.> (Display DSP Firmware Build Number) is sent, the imager returns: <#d/35-XXXXXX-RR.BBB>. • When <#k.> (Display Kernel Firmware Build Number) is sent, the imager returns: <#k/35-XXXXXX-RR.BBB>. • When <#p.> (Display System Configuration File Build Number) is sent, the imager returns: <#p/35-XXXXXX-RR.BBB>.

7-20

QX Hawk Industrial Imager User Manual

Page 303

Utilities

Bar Code Configuration Mode Definition: Serial Cmd:

Bar Code Configuration Mode is a way of programming the imager by using ECC 200 Data Matrix symbols. <BCCFG>

Bar Code Configuration Mode can be entered three different ways: 1. By forcing the imager into Bar Code Configuration Mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ Button positions to Bar Code Configuration Mode. 3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022 to signify imager programming. This can be either in a regular read cycle or during a read rate test. Reading this symbol in the calibration routine will have no effect.1 Once Bar Code Configuration Mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the imager by printing labels in Microscan’s serial command format. Commands are processed as if the data were streamed in through the serial port. The imager will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the imager to produce more serial output, such as serial verification or counter requests, the data will be routed to the host port. Bar Code Configuration Mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ Button. The command to exit Bar Code Configuration Mode can be included as part of the Data Matrix symbol. For example, try encoding <K200,4><K220,1><J> into a Data Matrix symbol. This configures the imager to enable Serial Trigger Mode, to program a new trigger to end the read cycle, and to exit Bar Code Configuration Mode with <J>. To end all EZ Button functions, press the EZ Button once and quickly release.

1. In normal reading modes, it is required to read a special Data Matrix symbol with a special codeword used by ISO/IEC 16022 to signify imager programming.

QX Hawk Industrial Imager User Manual

7-21

Page 304

Calibration

Calibration Sending the <@CAL> command from ESP’s Terminal initiates auto-calibration without entering the auto-calibration menu. The calibrated parameters are determined by the settings of the Calibration Options command.

Lens Calibration Important: The <@OPTIC> command should only be used when changing the lens module. Important: <@OPTIC> is not supported by the QX Hawk C-Mount Imager. Sending the <@OPTIC> command puts the imager into a setup mode for the purpose of improving the accuracy of the focal distance parameter (<K525>). The imager comes with a default focal curve based on unit averages. When this isn’t close enough to obtain all distances, the <@OPTIC> command can be used to start a 2-point test to normalize the focal distance and improve accuracy. This should generally be done with lenses that were not originally shipped with the imager. Important: <K525> is not supported by the QX Hawk C-Mount Imager. The table below shows the setting and test requirements to improve distance parameter accuracy. Lens Type and Command <K525,,1> (.) UHD 15° <K525,,2> (..) HD 30° <K525,,3> (…) SD 45° <K525,,4> (○) SD 12°

7-22

Inside Test Requirements 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm 10 mil/0.25 mm Data Matrix @ 1.0”/25 mm

Outside Test Requirements 30 mil/0.75 mm Data Matrix @ 10”/254 mm 30 mil/0.75 mm Data Matrix @ 10”/254 mm 30 mil/0.75 mm Data Matrix @ 10”/254 mm 30 mil/0.75 mm Data Matrix @ 10”/254 mm

QX Hawk Industrial Imager User Manual

Page 305

Utilities

Default/Reset/Save Understanding and controlling the imager’s active, saved, and default settings are critical to its successful operation.

Saved for Power-On

Resets (Not Saved for Power-On)

Function Reset (Will not save for power-on)

Serial Cmd

ESPa

<A>

Save to Reader, Send No Save

Reset and Recall Microscan Default Parameters Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters

<Ard>

Send <Ard> from Terminal

<Arp>

Send <Arp> from Terminal

<Arc>

Send <Arc> from Terminal

Save Current Settings for Power-On

<Z>

Save Current Settings as Customer Default Parameters for Power-On

<Zc>

Recall Microscan Default Settings and Save for Power-On (Will not default “sticky parameters”)

<Zrd>

Send <Zrd> from Terminal

Recall Customer Default Settings and Save for Power-On

<Zrc>

Send <Zrc> from Terminal (You can also press and hold the EZ Button while powering on the imager to send this command.)

Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb a. When right-clicking in a tree control to select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the imager itself, follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled in Preferences (General tab), accessible from the Options dropdown menu.

Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.

Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the imager or the <Arp> command is sent.

Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.

QX Hawk Industrial Imager User Manual

7-23

Page 306

Default/Reset/Save

Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a back-up set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default (jumper the default pin to ground) does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ Button default to restore the known Microscan defaults, the user can then recall the previous customer-saved settings with an <Arc> or <Zrc> command.

Restore Customer Defaults Use the EZ Button to default the scanner by holding it down while applying power to the scanner (if this feature is enabled).

Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed.

Software Defaults Microscan default parameters can be recalled (loaded into current settings) with the <Ard> command or recalled and saved for power-on with the <Zrd> command.

Hardware Default If a software default and reset is not possible, it may be necessary to reset the imager by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset. 1. Apply power to the imager. 2. Locate default pin and ground. Ensure that the correct pins are located, as connecting the wrong pins may cause serious damage to the imager. 3. Momentarily connect the wires (or pins) and listen for a series of short beeps that last approximately 3 seconds. 4. Within 3 seconds, disconnect and then re-connect the two wires again. A longer beep should be heard. If not, repeat the process above.

Default on Power-On Use the EZ Button to default the imager by holding it down while applying power to the imager (if this feature is enabled). 7-24

QX Hawk Industrial Imager User Manual

Page 307

Utilities

Imager Status <?> Imager Status Request The imager responds to a status request <?> with a two character hex value, such as <?/22>. To determine status: 1. Look up the binary conversion in the table below. For example, the first hex 2 would be 0 0 1 0 in binary, as read from binary digits 3 through 0; the second hex 2 is also 0 0 1 0 as read from binary digits 7 through 4. 2. Next, enter your binary values from the table below in the “Binary” column next to the appropriate bit. Binary Bit 0 1 2 3 4 5

Binary 0 1 0 0 0 1

Imager Status Command error detected Command received Communication error detected Flash sector unprotect failure Host/Aux port buffer overflow Imager is in a read cycle

3. Under “Binary,” interpret 1s as true and 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received”. Bit 5 is also a 1, indicating that the “Imager is in a read cycle”.

Hex Value 0 1 2 3 4 5 6 7 8 9 A B C D E F

Bit Digits 7

6

5

4

3

2

1

0

0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

<K?> All Status Request This is the fastest way to learn the imager’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.

<K??> All Descriptor Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.

<K?#> All Range Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest user-defined K command value.

QX Hawk Industrial Imager User Manual

7-25

Page 308

Imager Status

<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.

<Knnn??> Single Descriptor Request This request returns the basic functional description of all fields in the requested K command.

<Knnn?#> Single Range Request This request will return the value range and storage type description of all fields in the requested K command.

<Knnnd> Single Command Default This request will default a single K command to original factory parameters.

7-26

QX Hawk Industrial Imager User Manual

Page 309

Utilities

Learn Operations Initiate Learn Operation Sending the <LEARN> command from ESP’s Terminal will put the imager into a mode of operation that will cause it to “learn” the next Data Matrix symbol decoded. This mode of operation will remain active until either a Data Matrix symbol is decoded or the call is made to disable the mode and revert back to normal operation. Upon decoding a Data Matrix symbol, the image processing will save pertinent information regarding the target symbol to allow it to be processed more quickly and consistently. The data collected by the Learn operation can be saved for a Power-On condition by sending the <Z> command.

Initiate Unlearn Operation Sending the <UNLEARN> command will cause the imager to discard any information acquired during a Learn operation. The Unlearn state can be saved for a Power-On condition by sending the <Z> command.

Display Learn Status Sending the <LEARN?> request will return the current status of Learn operations. Responses are sent in this format: <LEARN,0> (Default; symbol has not been learned.) <LEARN,1> (Learn operation in progress.) <LEARN,2> (Symbol has been learned.)

Learn Persistence The learn state and parameters persist in the same way as ordinary parameters. Examples: • A QX Hawk in a Learned state has not been saved. Cycling power will remove any Learned state information and the imager will power-on in its configured state. • A QX Hawk is saved in a Learning state. The imager will power-on in the Learning state and will learn the first Data Matrix symbol decoded. • A QX Hawk is saved in a Learned state. The imager will power-on in the Learned state and will only decode the learned symbol type. • A QX Hawk in a Learned state is issued a reset default command <Ard>. The unit will return to an Unlearned state but if power is cycled it will return to its saved state.

QX Hawk Industrial Imager User Manual

7-27

Page 310

Reboot System

Reboot System Sending a <reboot> command from ESP’s Terminal will “cold-reboot” the system, starting from Boot Code.

7-28

QX Hawk Industrial Imager User Manual