Page 291

Utilities

Device Control Click the Utilities button and then the Device Control tab to display the Device Control view.

The Output 1 Pulse, Output 2 Pulse, and Output 3 Pulse buttons activate the link between the + and – of the host connector. The buttons in the Extras section Disable or Enable the imager.

Device Control Serial Utility Commands Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector (regardless of Master Symbol or Output 1 status).

Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector (regardless of Master Symbol or Output 2 status).

Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector (regardless of Master Symbol or Output 3 status).

End Current Read Cycle Sending <I> will turn the imager OFF, end the current read cycle, and will not allow the imager to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the imager is being configured. Disabling the imager will not affect any commands that have already been downloaded.

Enable Read Cycle Sending <H> will turn the imager ON and allow it to enter read cycles.

QX Hawk Industrial Imager User Manual

7-9

Page 292

Differences from Default

Differences from Default Click the Utilities button and then the Differences tab to display the Differences from Default view.

Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.

Click Generate Barcode to display the Bar Code Dialog. Then create configuration symbols containing the required configuration commands.

Send configuration settings to the imager without saving by clicking Send to Reader.

Click Save As to save the report as plain text or a tab-delimited text file.

Send configuration settings to the imager and save in ESP by clicking Send and Save.

• To create a symbol containing any of the command settings in the table, click Generate Barcode. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the imager and save them, or Send to Reader to send the settings without saving them. Important: To use Differences from Default, connect to the imager and Receive Reader Settings via the Send/Recv button on the toolbar. 7-10

QX Hawk Industrial Imager User Manual

Page 293

Utilities

Master Database Click the Utilities button and then the Master Database tab to display the Master Database view.

Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.

Master Database Overview Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands. 1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which the master symbol will be entered. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.

Loads the next symbol decoded into the selected index.

Saves the database to the imager. Loads the imager’s saved master symbols into ESP.

Double-click a row to enter data into popup text box.

QX Hawk Industrial Imager User Manual

7-11

Page 294

Master Database

Master Symbol Database Size Master Symbol Database Size allows the user to select 1 to 10 master symbols for the master symbol database.

Set Master Symbol Database Size here.

Important: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol # 1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5 #6 #7 #8 #9 # 10

7-12

Maximum Characters 3000 1500 1000 750 600 500 428 375 333 300

QX Hawk Industrial Imager User Manual

Page 295

Utilities

Enter Master Symbol Data Allows the user to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Enter data for 1 to 10 master symbols. Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols to be created in Master Symbol Database Size. 3. Double-click on each master symbol number in the table, type master symbol data in the popup dialog that appears, and click OK. 4. When all master symbol data has been entered, click the Send Database to the Reader button.

QX Hawk Industrial Imager User Manual

7-13

Page 296

Master Database

Request Master Symbol Data Returns master symbol data for any enabled master symbols from 1 to 10. 1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.

Store Next Decoded Symbol to Database Index 1 After the size of the database is set, the imager can read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G>.

Store Next Decoded Symbol to Database Index n To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab, 1. Select the master symbol index number in which new symbol data will be stored. 2. Click the Read Symbol into Selected Index button.

Caution: If an index with existing data is selected, that data will be overwritten by the new decoded data when this command is used.

7-14

QX Hawk Industrial Imager User Manual

Page 297

Utilities

New Master Load Status Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. Send the <NEWM> command from ESP’s Terminal. The imager returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.

QX Hawk Industrial Imager User Manual

7-15

Page 298

Delete Master Symbol Data Master symbol data can be deleted using ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number to be deleted. 3. Delete text and click OK.

7-16

QX Hawk Industrial Imager User Manual

Page 299

Utilities

Firmware Click the Utilities button and then the Firmware tab to display the Firmware view.

Firmware Update Firmware Update is used to download application code to the imager. Application code versions are specific to the imager. Consult with a sales representative before downloading application code. If needed, application code can be requested from Microscan. To download application code: 1. First, be sure that the imager is connected to the host computer. 2. Apply power to the imager. 3. In the Firmware Update dropdown menu, select App Code. This will open a dialog that allows the user to browse for the application code file. 4. Navigate to where the application code file is located on the host computer. 5. Allow approximately a minute for firmware to download. As the application code begins to download, the imager will be silent, the LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will show when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.

QX Hawk Industrial Imager User Manual

7-17

Page 300

Firmware

Firmware Verification Request Part Number Send a request to the imager for application code, boot code, DSP code, or kernel code part numbers. 1. Click the Firmware tab. 2. Select App Code, Boot Code, DSP Code, or Kernel Code from the dropdown menu to the left of the Request Part No. button. 3. Click the Request Part No. button to see the part number displayed in the text field to the right.

Request Part Number by Serial Command Note: X = base part number; R = revision number • When <#> (Display All Firmware Part Numbers) is sent, the imager returns: <#a/35-XXXXXX-RR><#b/35-XXXXXX-RR><#d/35-XXXXXX-RR><#k/35-XXXXXX-RR> <#p/Sys_Cfg_P/N><#s/SafeMode_P/N>. • When <#a> (Display Application Firmware Part Number) is sent, the imager returns: <#a/35-XXXXXX-RR>. • When <#b> (Display Boot Firmware Part Number) is sent, the imager returns: <#b/35-XXXXXX-RR>. • When <#d> (Display DSP Firmware Part Number) is sent, the imager returns: <#d/35-XXXXXX-RR>. • When <#k> (Display Kernel Firmware Part Number) is sent, the imager returns: <#k/35-XXXXXX-RR>. • When <#p> (Display System Configuration File Part Number) is sent, the imager returns: <#p/Sys_Cfg_P/N>. • When <#s> (Display SafeMode Firmware Part Number) is sent, the imager returns: <#s/SafeMode_P/N>.

7-18

QX Hawk Industrial Imager User Manual