Page 261
Parameters
Report Tab The Report tab allows the user to initiate Data Matrix Grading and to generate and save grading reports. To save the report as a PDF file, an HTML file, a CSV file, or an RTF file, click the Save Report button. Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons.
The Symbol Quality interface is divided into three sections: Report, Locate, and Preferences.
The imager’s field of view is shown here. When grading is completed, the initial report is also shown in this viewing area.
QX Hawk Industrial Imager User Manual
5-163
Page 262
Symbol Quality
Locate Tab The Locate tab allows the user to determine the position of the symbol within the imager’s field of view, and to optimize the imager’s camera settings for symbol quality evaluation.
Click the Locate button to display the symbol in the imager’s field of view.
5-164
Click the Calibrate button to optimize camera settings.
QX Hawk Industrial Imager User Manual
Page 263
Parameters
Preferences Tab The Preferences tab allows the user to set defaults that are automatically activated when grading is completed. For this reason, the user is advised to set preferences before performing grading.
This information is appended at the bottom of the report.
Choose the default report type to be generated when you click Save Report on the Report tab. Check Autofit Content to ensure that saved PDF report content will fit on a single page.
Typically you will be asked where you wish to store your report. If you do not want to be prompted to choose a file path, click Store Report without file path prompt.
Click the Include Image check box to output the captured symbol image with your saved report as a Bitmap or JPEG image file.
Enables ESP to parse UII symbol data into the correct fields and output order defined by the U.S. Department of Defense IUID initiative.
Returns all settings to default.
Returns all settings to most recent.
QX Hawk Industrial Imager User Manual
5-165
Page 264
Matchcode
Matchcode Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Matchcode tab to display the Matchcode tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the Matchcode section of Appendix E.
5-166
QX Hawk Industrial Imager User Manual
Page 265
Parameters
Overview of Matchcode Matchcode allows the user to store master symbol data in the imager’s memory, compare that data against other symbol data, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be set up for up to 10 master symbols. Note: Matchcode will function with multiple symbols; however, if Matchcode Type is set to Sequential or if Trigger Mode is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration. Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.
Steps for Entering and Using Master Symbols 1. Set Trigger Mode to External Level, External Edge, or Serial Data. 2. Choose the method of symbol comparison that fits the application. 3. Define the type of output required with Matchcode setup: a. Symbol data output b. Discrete output 4. Select the number of master symbols required. 5. Decide how the master symbol(s) will be entered: a. Use ESP to type master symbol data directly. b. Send a serial command with symbol data in the form of <K231,master symbol#, data>. c. Send a <G> (Read Next Symbol as Master Symbol) command. d. Enable the New Master Pin command and activate the discrete input to store the next symbol read as the master symbol.
QX Hawk Industrial Imager User Manual
5-167
Page 266
Matchcode
Matchcode Type Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Trigger Mode to External Level, External Edge, or Serial Data.
Wild Card Allows the user to enter user-defined wild card characters in the master symbol. Note: If Matchcode Type is set to Sequential, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
Sequential Instructs the imager to compare symbols or portions of symbols with the master symbol. Instructs the imager to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers.
Sequential Matching Useful in tracking product serial numbers that increment or decrement sequentially. With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.
5-168
QX Hawk Industrial Imager User Manual
Page 267
Parameters
Match Start Position Match Start Position is useful in defining specific portions of a symbol for comparison. For example, if a symbol contains a part number, manufacturing date, and lot code info, but only the part number information is needed, set the imager to sort only the part number and to ignore the other characters. Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential. For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length. Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
Match Length Example: If Match Length is set to 6 in a 10-character symbol, and Match Start Position is set to 2, only the 2nd through 7th characters (from left to right) will be compared. Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. When Match Start Position is set to 0, no comparison will occur.
QX Hawk Industrial Imager User Manual
5-169
Page 268
Matchcode
Wild Card Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering the wild card at the end of the master symbol, as in CR*, will result in matches for variable symbol lengths such as CR1, CR23, CR358, etc. Wild Card Character allows a user to define a wild card character as part of the master symbol.
5-170
QX Hawk Industrial Imager User Manual
Page 269
Parameters
Sequence on No Read Sequence on No Read is useful when the imager needs to stay in sequence even if no decode occurs. When Sequence on No Read is Enabled and Matchcode Type is set to Sequential, the imager sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read.
Consider the following decodes as an example of Sequence on No Read Enabled: Master Symbol 001 002 003 004 005 006 007
Decoded Symbol 001 002 No Read 004 No Read No Read 007
Master Symbol after Decode 002 003 004 (sequence on No Read) 005 006 (sequence on No Read) 007 (sequence on No Read) 008
Consider the following decodes as an example of Sequence on No Read Disabled: Master Symbol 001 002 003 003 004 004 004
Decoded Symbol 001 002 No Read 003 No Read No Read 004
QX Hawk Industrial Imager User Manual
Master Symbol after Decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005
5-171
Page 270
Matchcode
Sequence on Mismatch Note: Matchcode Type must be set to Sequential for this command to function. Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur. The imager will sequence the master to one more or one less than the decoded symbol.
Consider the following decodes as an example of Sequence on Mismatch Enabled: Master Symbol 001 002 003 004 005 006 007
Decoded Symbol 001 002 abc 004 def ghi 007
Master Symbol after Decode 002 003 004 (sequence on mismatch) 005 006 (sequence on mismatch) 007 (sequence on mismatch) 008
Consider the following decodes as an example of Sequence on Mismatch Disabled: Master Symbol 001 002 003 004 005 006 006
5-172
Decoded Symbol 001 002 abc 004 def ghi 006
Master Symbol after Decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced) 007
QX Hawk Industrial Imager User Manual