Page 271
Parameters
Sequence Step When the master symbol is sequenced (incremented/decremented), Sequence Step defines the magnitude of change.
New Master Pin If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 ms), master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Master Symbol Database Size parameter.
New Master Load Status The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Master Symbol Database Size set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>.
QX Hawk Industrial Imager User Manual
5-173
Page 272
Matchcode
Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.
Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.
5-174
QX Hawk Industrial Imager User Manual
Page 273
Parameters
Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the 'LDJQRVWLFV section of Appendix E.
QX Hawk Industrial Imager User Manual
5-175
Page 274
Diagnostics
Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.
Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.
Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.
5-176
QX Hawk Industrial Imager User Manual
Page 275
Parameters
Service Message Status When Enabled, a Service Message of up to 128 characters is sent whenever the system detects that the service time has expired.
Service Message Allows the user to define a service message of up to 128 characters.
Threshold Allows the user to determine the length of time until the service message will be sent.
Resolution The service timer has a resolution field for setting up the timer increment. Options are increments of seconds or minutes.
QX Hawk Industrial Imager User Manual
5-177
Page 276
Diagnostics
User-Defined Name User-Defined Name allows the user to enter any combination of ASCII characters to identify the imager.
5-178
QX Hawk Industrial Imager User Manual
Page 277
6 Terminal Contents Terminal View............................................................................................................................... 6-2 Find .............................................................................................................................................. 6-3 Send ............................................................................................................................................. 6-4 Macros.......................................................................................................................................... 6-5 Terminal Menus............................................................................................................................ 6-6
This section describes the multiple functions of ESP’s Terminal interface.
QX Hawk Industrial Imager User Manual
6-1
Page 278
Terminal View
Terminal View Click this button to display the Terminal view. Copy, paste, save
Clear screen
Macros listed on this bar
Type text here to find matching text in the Terminal window.
Terminal screen
Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
Type serial commands here.
Click on desired Macro to run.
The Terminal interface allows the user to send serial commands to the imager by using macros, by copying and pasting, or by typing commands in the Send text field. The Terminal also displays symbol data or information from the imager. Right-clicking on the Terminal screen displays a menu of additional options.
6-2
QX Hawk Industrial Imager User Manual
Page 279
Terminal
Find The Find function allows the user to enter text strings to be searched for in the Terminal. For example: 1. Type “ABC” into the Find box.
2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.
QX Hawk Industrial Imager User Manual
6-3
Page 280
Send
Send The Send function allows the user to enter serial commands and then send them to the imager. 1. Type the command into the Send box.
2. Press Enter. 3. Click the Send button to the left of the text field to send the command additional times.
6-4
QX Hawk Industrial Imager User Manual