Parameters
Number of Triggers The number of triggers to examine for the trend analysis condition.
Number to Output On Example: If Number to Output On is set to 3 and Trend Analysis Mode is set to No Read, then the output will not be activated until 3 No Reads have occurred. Sets the number of Trend Analysis Mode events (mismatches, No Reads, or reads/trigger as configured by Trend Analysis Mode) to occur within the trigger evaluation period before activating the associated output.
QX Hawk Industrial Imager User Manual
5-153
Page 252
I/O Parameters
Decodes per Trigger When set to this mode, and when the appropriate output is set to output on trend analysis, the imager will function in a Decodes per Trigger mode during the read cycle and the trend analysis operation. Output will be activated based on whether or not the symbol decode count at the end of the read cycle is less than the decodes per trigger threshold. Note: Although this setup causes the imager to function in a Decodes per Trigger mode, the decode count will only be appended to the symbol data if the status of the Decodes per Trigger command is enabled.
Example: Decodes per Trigger threshold: 100 100 or more decodes = No output Fewer than 100 decodes = Output fires
5-154
QX Hawk Industrial Imager User Manual
Page 253
Parameters
Symbol Quality (ISO/IEC 16022)
Output on Symbol Contrast The symbol contrast is formatted and attached to the Data Matrix symbol data as either a grade or value.
Output on Print Growth The print growth is formatted and attached to the Data Matrix symbol data as either a grade or value.
Output on Axial Non-Uniformity The axial non-uniformity is formatted and attached to the Data Matrix symbol data as either a grade or value.
Output On Unused ECC The unused ECC is formatted and attached to the Data Matrix symbol data as either a grade or value.
QX Hawk Industrial Imager User Manual
5-155
Page 254
I/O Parameters
Symbol Contrast Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Symbol Contrast grade is under the threshold.
Print Growth Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Print Growth grade is under the threshold.
Axial Non-Uniformity Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Axial Non-Uniformity grade is under the threshold.
Unused ECC Threshold This is the grade to use as a threshold for driving the output. Output will be driven if the Unused ECC grade is under the threshold.
5-156
QX Hawk Industrial Imager User Manual
Page 255
Parameters
Diagnostics Note: Output On under Output 3 Parameters must be set to Diagnostic Warning for this output to function. Under Output 3 Parameters, expand the Diagnostics tree. When Diagnostic Warning is enabled, the Output On configuration has no effect. The output will remain active as long as one of the diagnostic warning conditions is met. The output will become inactive once it detects that there are no diagnostic warning conditions.
Service Unit Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note: This feature cannot be used if the imager is in Continuous Read. When Service Unit is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes.
QX Hawk Industrial Imager User Manual
5-157
Page 256
I/O Parameters
Quality Output
Quality Output Separator The separator character separates quality output data from symbol data.
Decodes per Trigger Status When Enabled, the imager enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the imager outputs any decoded symbol data along with the decodes per trigger count.
5-158
QX Hawk Industrial Imager User Manual
Page 257
Parameters
Symbol Quality Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Symbol Quality tab to display the Symbol Quality tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Symbol Quality settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format.
QX Hawk Industrial Imager User Manual
5-159
Page 258
Symbol Quality
Global
Total Read Time When enabled, outputs the amount of time that was required by the imager to decode the symbol.
Symbol Quality Separator This field specifies the separator used to separate the quality output data.
Output Mode Determines how symbol quality evaluations will be output.
5-160
QX Hawk Industrial Imager User Manual
Page 259
Parameters
Data Matrix
ISO/IEC 16022 Parameters
Symbol Contrast Outputs the candidate symbol’s Symbol Contrast value.
Print Growth Outputs the candidate symbol’s Print Growth value.
Axial Non-Uniformity Outputs the candidate symbol’s Axial Non-Uniformity value.
Unused ECC Outputs the candidate symbol’s Unused ECC value.
QX Hawk Industrial Imager User Manual
5-161
Page 260
Symbol Quality
Grading
Percent Cell Damage The percent of symbol cells that are damaged.
Capture Time The amount of time the imager required to capture the area in which the symbol was located.
Locate Time The amount of time the imager required to locate the symbol.
Decode Time The amount of time the imager required to decode the symbol.
Pixels Per Element The average number of pixels in a symbol element.
ECC Level The level of error correction used when decoding the symbol.
Matrix Size The size of the symbol’s matrix area (the area composed of the symbol’s elements).
Quiet Zone The size of the quiet zone around the symbol.
Symbol Angle The angle at which the symbol is printed or marked.