Page 201
Parameters
Output Indicators
The QX Hawk has a beeper and two LED arrays, as follows: 1. An array of green LEDs projected from the front of the imager that can be programmed to flash in response to user-defined conditions. 2. An array of status LEDs on the side of the imager.
Green Flash Mode
Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the imager can be programmed to flash in response to user-defined conditions.
Disabled Green flash LEDs are disabled.
Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.
QX Hawk Industrial Imager User Manual
5-103
Page 202
I/O Parameters
Static Presentation Static Presentation Mode is used in conjunction with Continuous Read mode. When operating in Static Presentation Mode, the red LEDs will illuminate while the imager is searching for a symbol in Continuous Read mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the imager is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
Strobe The green flash will be used as an illumination strobe for image capture. If it is required that the green flood is the only illumination for image capture then the internal illumination LED’s can be disabled.
5-104
QX Hawk Industrial Imager User Manual
Page 203
Parameters
Targeting
Always Off The targeting LEDs remain off.
On Only When Not In Read Cycle The targeting LEDs illuminate while the imager is not in a read cycle. When a read cycle is entered the targeting LEDs will turn off, they will come back on upon exiting.
On Only When In Read Cycle The targeting LEDs illuminate upon entering a read cycle, and will turn off upon exiting the read cycle.
Always On The targeting LEDs are always illuminated.
Green Flash Duration Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value.
QX Hawk Industrial Imager User Manual
5-105
Page 204
I/O Parameters
Beeper An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. Note: The beeper will also sound at any of the following times: • When the imager is defaulted. • When a Send and Save command is sent from ESP. • At the conclusion of an Auto Calibration procedure. • When a <Z>, <Zrd>, or <K701,,1> command is sent from ESP’s Terminal.
5-106
QX Hawk Industrial Imager User Manual
Page 205
Parameters
LED Configuration When the Symbol Grade Standard is set to ISO/IEC 16022 grade and the Bar Graph is configured for Grading, this parameter determines which ISO/IEC 16022 grade to display on the LED bar graph. Using the read rate scale as reference if the ISO/IEC 16022 grade result was a grade A, all the LEDs from 20% to 100% would be illuminated. If the result was a grade F, only the 20% LED would illuminate.
ISO/IEC 16022 Grade
Final Grade LEDs represent ISO/IEC 16022 final grade. Symbol Contrast LEDs represent ISO/IEC 16022 Symbol Contrast grade. Print Growth LEDs represent ISO/IEC 16022 Print Growth grade. Axial Non-Uniformity LEDs represent ISO/IEC 16022 Axial Non-Uniformity grade. Unused ECC LEDs represent ISO/IEC 16022 Unused ECC grade.
QX Hawk Industrial Imager User Manual
5-107
Page 206
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status This command is useful in removing any doubt about the imager’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K141,1,START> is entered, the imager will echo back <K141,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. Host Imager If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Command Beep Status Used to audibly verify the acceptance and validity of a command. Causes the imager to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the imager beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
5-108
QX Hawk Industrial Imager User Manual
Page 207
Parameters
Control / Hex Output Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M.
QX Hawk Industrial Imager User Manual
5-109
Page 208
I/O Parameters
EZ Trax Output EZ Trax Output Status When EZ Trax output is enabled, the imager will attempt to output all enabled EZ Trax options. EZ Trax will not function unless enabled.
Comm Port Selects the communication port that will be used to transfer image files.
Image Mode Determines which read cycle condition triggers image file output.
Image Format Selects the format of the image output file.
5-110
QX Hawk Industrial Imager User Manual
Page 209
Parameters
JPEG Quality Sets the amount of JPEG image compression. A value of 1 represents the highest compression and lowest image quality, and 100 represents the lowest compression and highest image quality.
Object Info Output If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included.
Grade Output Symbol quality information will be output in the form of an abbreviated identifier for each read cycle.
QX Hawk Industrial Imager User Manual
5-111
Page 210
I/O Parameters
EZ Button
EZ Button
Serves as a master switch to enable/disable the EZ Button status. The EZ Button has four positions: Single Beep, Two Beeps, Three Beeps, and Four Beeps, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight EZ Button Modes.
5-112
QX Hawk Industrial Imager User Manual