Page 191
Parameters
Codeword Collection
Single Image The imager will attempt to decode the PDF417 symbol only from the information provided in a single image.
Multiple Image The imager will process codewords from multiple images within the same read cycle and combine them to decode a single PDF417 symbol.
QX Hawk Industrial Imager User Manual
5-93
Page 192
Symbologies
MicroPDF417 Used for labelling small items that need large data capacity. A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol.
Fixed Symbol Length Status When Enabled, the imager will reject any MicroPDF417 symbol that does not match the Fixed Symbol Length.
Fixed Symbol Length Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the MicroPDF417 symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The imager will ignore any symbol not having the specified length.
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
5-94
QX Hawk Industrial Imager User Manual
Page 193
Parameters
Aztec Code Used in document imaging, railway ticket validation, and some postal applications. A 2D matrix symbology built on a square grid with a square “bull’s-eye” pattern at the center. Aztec Code can encode up to 3,832 numeric or 3,067 alphabetical characters, or 1,914 bytes of data. The level of Reed-Solomon error correction used with Aztec Code is configurable, from 5% to 95% of the total data region. The recommended error correction level is 23% of symbol capacity plus codewords.
Disabled The imager will not attempt to decode Aztec symbols.
Enabled The imager will attempt to decode Aztec symbols.
QX Hawk Industrial Imager User Manual
5-95
Page 194
Symbologies
Composite When set to Enabled or Required, will decode the 2D composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E.
Enabled If Composite is set to Enabled, the imager will decode both the 2D composite and linear components. However, if the 2D composite component is not decoded, the linear data will be sent by itself at the end of the read cycle.
Required If set to Required, the imager must decode both components, or a No Read will occur.
Separator Status Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component.
Separator The Separator Character will be the same as the character defined in the Multisymbol Separator field. As required by the application. Allows the user to change the separator character from a comma to a new character.
5-96
QX Hawk Industrial Imager User Manual
Page 195
Parameters
Symbology Identifier Symbology Identifier is a standard prefix set of characters that identifies the symbol type. When enabled, the imager analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, L, e, or Q • (A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code 93; I = Interleaved 2 of 5; L = PDF417 and MicroPDF417; e = GS1 DataBar (RSS); Q = Pharmacode) • Modifier Example: ]C indicates a Code 128 symbol.
Disabled When set to Disabled, symbol data output does not contain Symbology Identifier information.
Enabled When set to Enabled, symbol data output contains a Symbology Identifier sequence.
Explanation of Modifiers for Code 39, Codabar, and Interleaved 2 of 5 • For Code 39, Codabar, and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier
Check Character
0 1 3 4 5 7
Disabled Enabled Enabled Disabled Enabled Enabled
Check Character Output N/A Enabled Disabled N/A Enabled Disabled
Full ASCII Conversion (Code 39 Only) No No No Yes Yes Yes
Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.
Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates EAN 128; otherwise the modifier is 0. • For all other symbologies, the modifier is 0.
QX Hawk Industrial Imager User Manual
5-97
Page 196
I/O Parameters
I/O Parameters Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the I/O tab to display the I/O Parameters tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: I/O Parameters settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the I/O Parameters section of Appendix E.
5-98
QX Hawk Industrial Imager User Manual
Page 197
Parameters
Symbol Data Output Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.
Symbol Data Output Status Disabled It is useful when an application only needs to use the discrete outputs and can allow the imager to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the imager will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)
Match Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the imager transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A No Read can still be transmitted if Enabled.
Mismatch Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the imager transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A No Read can still be transmitted if Enabled.
Good Read Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the imager transmits symbol data on any good read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if Enabled.
QX Hawk Industrial Imager User Manual
5-99
Page 198
I/O Parameters
When to Output Symbol Data This command allows the user to choose when symbol data can be sent to the host.
As Soon As Possible As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded.
End of Read Cycle End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time that it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle
Start of read cycle Read cycle duration Host activates trigger
5-100
This is when host expects output
QX Hawk Industrial Imager User Manual
Page 199
Parameters
No Read Message Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.
No Read Message Status Disabled Only symbol data is output after a read cycle.
Enabled When the imager is in a triggered mode, a No Read message will be appended for each failed read attempt.
Message Any combination of ASCII characters can be defined as the No Read message. Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character.
QX Hawk Industrial Imager User Manual
5-101
Page 200
I/O Parameters
Read Duration Output Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output. Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.
Separator User-defined character that separates the symbol information from the Read Duration Output.
5-102
QX Hawk Industrial Imager User Manual