Page 181
Parameters
Code 93 Used in some clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces.
Fixed Symbol Length Status When disabled, the imager will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the imager will reject any Code 93 symbol that doesn’t match the fixed symbol length.
Fixed Symbol Length This is the symbol length value against which all Code 93 symbols will be compared.
QX Hawk Industrial Imager User Manual
5-83
Page 182
Symbologies
Pharmacode Used mostly in pharmaceutical packaging. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros.
Important: When Pharmacode is enabled, other linear symbologies will not decode properly. Disable Pharmacode before reading other linear symbologies.
Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid.
Symbol Length Specifies the exact number of bars that must be present for the imager to recognize and decode the Pharmacode symbol.
Minimum Bars Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid.
5-84
QX Hawk Industrial Imager User Manual
Page 183
Parameters
Bar Width Status If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the imager is able to tell the difference between the narrow and the wide bars.
Direction Specifies the direction in which a symbol can be read.
Fixed Threshold Value Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar.
Background Color Specifies whether the symbol will be presented on a black background or a white background.
QX Hawk Industrial Imager User Manual
5-85
Page 184
Symbologies
Postal Symbologies Important: Postal Symbologies must have a pixels-per-element value of no more than 7 to be decoded reliably by the QX Hawk. The imager must be configured to specific read range, field of view, and camera parameters before decoding Postal Symbologies.
Position the postal symbol in the center of the imager’s field of view.
5-86
QX Hawk Industrial Imager User Manual
Page 185
Parameters
Postal Symbology Type 1D Postal Symbologies are used in mail sortation, auditing, certified mail, registered mail, metered mail, and point-of-sale (POS) applications. This commend determines the postal symbology that will be decoded by the imager.
U.S. Postal (POSTNET, PLANET, USPS4CB) When U.S. Postal is enabled, the imager will only decode POSTNET, PLANET, and USPS4CB symbols. Important: POSTNET Status, PLANET Status, and USPS4CB Status are enabled by default. However, if any of the three U.S. Postal symbologies is set to disabled individually, symbols of that type will not be decoded by the imager even when U.S. Postal is enabled. For example, if U.S. Postal is enabled but POSTNET Status is disabled, POSTNET symbols will not be decoded by the imager. See POSTNET Status, PLANET Status and USPS4CB Status for more detail about U.S. Postal symbologies.
Australia Post When Australia Post is enabled, the imager will only decode Australia Post symbols.
Japan Post When Japan Post is enabled, the imager will only decode Japan Post symbols.
Royal Mail When Royal Mail is enabled, the imager will only decode Royal Mail symbols.
KIX When KIX is enabled, the imager will only decode KIX symbols.
UPU When UPU is enabled, the imager will decode UPU symbols and any U.S. Postal symbologies that might be enabled. For example, if Postal Symbology Type is set to UPU and POSTNET Status is enabled and, the imager will attempt to decode both UPU and POSTNET symbols.
QX Hawk Industrial Imager User Manual
5-87
Page 186
Symbologies
POSTNET Status POSTNET is used by the United States Postal Service to direct mail. The ZIP Code or ZIP+4 Code is encoded in the symbol. Data is encoded in half-height and full-height bars, making POSTNET a “2-state” symbology. The delivery point (usually the last two digits of the address or post office box number) is also typically encoded in POSTNET symbols. If U.S. Postal and POSTNET Status are both enabled, the imager will decode POSTNET symbols.
PLANET Status PLANET (Postal Alphanumeric Encoding Technique) is a symbology used by the United States Postal Service to track and identify items during delivery. Each PLANET symbol is either 12 or 14 digits long, and encodes data in half-height and full-height bars, making PLANET a “2-state” symbology. The symbol always starts and ends with a full-height bar, or “guard rail”, and each individual digit is represented by a set of five bars in which two of the bars are always short. If U.S. Postal and PLANET Status are both enabled, the imager will decode PLANET symbols.
USPS4CB Status USPS4CB, also called Intelligent Mail, is used by the United States Postal Service to sort and track individual items as well as flats of mail. USPS4CB combines the capabilities of POSTNET and PLANET, and can encode 31 digits (65 bars). USPS4CB symbols are slightly longer than POSTNET symbols, and offer additional flexibility in choosing symbol height and width. Data is encoded in four types of bars (“states”), each of which is identified by a name and a value. This type of postal symbol is known as “4-state”. Each bar has a “tracker”, or middle section, to which an “ascender” (top section) or “descender” (bottom section) may be added. The 4-state format allows the symbol to contain more information, and makes it easier to decode. 4-state symbols can also be printed easily in a variety of media, including dot matrix, inkjet, and laser. If U.S. Postal and USPS4CB Status are both enabled, the imager will decode USPS4CB symbols.
5-88
QX Hawk Industrial Imager User Manual
Page 187
Parameters
POSTNET Allow B and B’ Fields If U.S. Postal and POSTNET are enabled, and POSTNET Allow B and B’ Fields is enabled, the imager will allow B and B’ fields in POSTNET symbols.
Australia Post Allow 0 FCC If Australia Post is enabled, and Australia Post Allow 0 FCC is enabled, the imager will allow 0 FCC in Australia Post symbols.
QX Hawk Industrial Imager User Manual
5-89
Page 188
Symbologies
GS1 DataBar Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology” or “RSS”.
DataBar Expanded Note: DataBar Expanded was previously known as “RSS Expanded”. Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and non-stacked).
Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field, minus the embedded check character. If disabled, any length would be considered valid.
Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the imager will recognize (this does not include start, stop, and check character characters). The imager ignores any symbol not having the specified length.
5-90
QX Hawk Industrial Imager User Manual
Page 189
Parameters
DataBar Limited Note: DataBar Limited was previously known as “RSS Limited”. DataBar Limited is designed to be read by laser scanners and CCD imagers. It is not recommended for omnidirectional slot imagers. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
DataBar Omnidirectional Note: DataBar Omnidirectional was previously known as “RSS-14”. Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar-14 is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. Note: Where appropriate, use 1 (non-stacked) for better performance instead of 2 (stacked; decode both stacked and non-stacked).
QX Hawk Industrial Imager User Manual
5-91
Page 190
Symbologies
PDF417 Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database. A two-dimensional, multi-row (3 to 90), continuous, variable-length symbology that has high data capacity (up to 2,700 numeric characters, 1,800 printable ASCII characters, or 1,100 binary characters per symbol). Each symbol character consists of 4 bars and 4 spaces in a 17-module structure.
Note: Sending <a1> from ESP’s Terminal will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Characters). This feature can be disabled by re-sending <a1>.
Fixed Symbol Length Status When Enabled, the imager will reject any PDF417 symbol that does not match the Fixed Symbol Length.
Fixed Symbol Length Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The imager will ignore any symbol not having the specified length.
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
5-92
QX Hawk Industrial Imager User Manual