The text of a manual · part 18 of 46
QX Hawk Industrial Imager User Manual, pages 171 to 180
Pages 171 to 180 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 171
Parameters
Interleaved 2 of 5 Interleaved 2 of 5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as symbol truncation. A dense, contimuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check character is highly recommended).
Check Character Status This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check character verification. An error correcting routine in which the check character character is added.
Check Character Output Status When enabled, a check character character is sent along with the symbol data for added data security.
QX Hawk Industrial Imager User Manual
5-73
Page 172
Symbologies
Symbol Length 1 Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. The Symbol Length 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Important: If Range Mode Status is set to Disabled, the length of the symbol must match either Symbol Length 1 or Symbol Length 2 to be considered a valid symbol. If Range Mode Status is set to Enabled, Symbol Length 1 and Symbol Length 2 form a range into which the length of the symbol must fall to be considered valid.
Symbol Length 2 Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. The Symbol Length 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Important: If Range Mode Status is set to Disabled, the length of the symbol must match either Symbol Length 2 or Symbol Length 1 to be considered a valid symbol. If Range Mode Status is set to Enabled, Symbol Length 2 and Symbol Length 1 form a range into which the length of the symbol must fall to be considered valid.
Guard Bar Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Useful when Interleaved 2 of 5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols. A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding the printed Interleaved 2 of 5 symbol and helping to prevent false reads.
5-74
QX Hawk Industrial Imager User Manual
Page 173
Parameters
Range Mode Status Important: Unless Range Mode is enabled, Symbol Length must be set to decode Interleaved 2 of 5 symbols. Useful in applications where Interleaved 2 of 5 symbols of a specific length are required. When Range Mode is disabled, the imager checks the value of the symbol length against the values set in Symbol Length 1 and Symbol Length 2. If the symbol length does not match either of the preset values, then it is rejected as invalid. When Range Mode is enabled, Symbol Length 1 and Symbol Length 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length 1 and Symbol Length 2 fields can form the start or end of the range.
QX Hawk Industrial Imager User Manual
5-75
Page 174
Symbologies
Codabar Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths.
Start and Stop Match Status When disabled, the imager will decode Codabar symbols whether or not the start and stop characters are the same. When enabled, the imager will not decode Codabar symbols unless the start and stop characters are the same.
Start and Stop Output Status When disabled, the start and stop characters will not be present in the data output of the decoded symbol. When enabled, the start and stop characters will be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation.
5-76
QX Hawk Industrial Imager User Manual
Page 175
Parameters
Large Intercharacter Gap When disabled, the spaces between characters, or the “intercharacter gap”, are ignored during the decode process. Note: If the intercharacter space is large enough to be considered a margin, the symbol will not decode, regardless of this parameter’s setting.
Fixed Symbol Length Status When disabled, the imager will accept any Codabar symbol provided it doesn’t exceed the system’s maximum capabilities. When enabled, the imager will reject any Codabar symbol that doesn’t match the fixed length.
Symbol Length This is the value against which all Codabar symbol lengths will be compared.
Check Character Type When disabled, the imager will not perform any character checking calculations on decoded Codabar symbols. When set to Mod 16, the imager will perform a modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to NW 7, the imager will perform an NW7 modulus 11 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to Both, the imager will perform both the Mod 16 and NW7 modulus 11 check character calculations on the symbol. If the symbol does not pass either calculation, it will not be decoded.
QX Hawk Industrial Imager User Manual
5-77
Page 176
Symbologies
Check Character Output Status When this field is disabled and a check character calculation is enabled, the imager will strip the verified check character from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the imager will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used.
5-78
QX Hawk Industrial Imager User Manual
Page 177
Parameters
UPC/EAN Used primarily in point-of-sale applications in the retail industry. It is commonly used with Microscan imagers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental data following the normal symbol. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the imager will read UPC Version A and UPC Version E only.
EAN Status EAN is the European version of the UPC symbology and is used in European retail applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN.
Note: The extra character identifies the country of origin.
QX Hawk Industrial Imager User Manual
5-79
Page 178
Symbologies
Supplementals Status Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the imager reads supplemental code data that has been appended to the standard UPC or EAN codes.
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.
Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required.
5-80
QX Hawk Industrial Imager User Manual
Page 179
Parameters
Separator Character As required by the application. Allows the user to change the separator character from a comma to a new character. Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command from ESP’s Terminal will return the current settings, including the separator character comma which appears after the separator status comma.
Supplementals Type As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both.
Both Either 2 character or 5 character supplementals will be considered valid.
Two Digits Only two character supplementals will be considered valid.
Five Digits Only five character supplementals will be considered valid.
QX Hawk Industrial Imager User Manual
5-81
Page 180
Symbologies
UPC-E as UPC-A When disabled, the imager will output the version E symbols in their encoded 6-character format. When enabled, the imager will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification.
5-82
QX Hawk Industrial Imager User Manual