Page 161
Parameters
Data Matrix
ECC 200 Status Disabled The imager will not attempt to decode ECC 200 symbols.
Enabled The imager will attempt to decode ECC 200 symbols.
ECC 000 Status Disabled The imager will not attempt to decode ECC 000 symbols.
Enabled The imager will attempt to decode ECC 000 symbols.
ECC 050 Status Disabled The imager will not attempt to decode ECC 050 symbols.
Enabled The imager will attempt to decode ECC 050 symbols.
ECC 080 Status Disabled The imager will not attempt to decode ECC 080 symbols.
Enabled The imager will attempt to decode ECC 080 symbols.
QX Hawk Industrial Imager User Manual
5-63
Page 162
Symbologies
ECC 100 Status Disabled The imager will not attempt to decode ECC 100 symbols.
Enabled The imager will attempt to decode ECC 100 symbols.
ECC 140 Status Disabled The imager will not attempt to decode ECC 140 symbols.
Enabled The imager will attempt to decode ECC 140 symbols.
ECC 120 Status Disabled The imager will not attempt to decode ECC 120 symbols.
Enabled The imager will attempt to decode ECC 120 symbols.
ECC 130 Status Disabled The imager will not attempt to decode ECC 130 symbols.
Enabled The imager will attempt to decode ECC 130 symbols.
5-64
QX Hawk Industrial Imager User Manual
Page 163
Parameters
QR Code
Disabled The imager will not attempt to decode QR Code symbols.
Enabled The imager will attempt to decode QR Code symbols.
QX Hawk Industrial Imager User Manual
5-65
Page 164
Symbologies
Micro QR Code
Disabled The imager will not attempt to decode Micro QR Code symbols.
Enabled The imager will attempt to decode Micro QR Code symbols.
5-66
QX Hawk Industrial Imager User Manual
Page 165
Parameters
Code 39 Code 39 is considered the standard for non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide.
Check Character Status Enables or Disables the check character.
Check Character Output Status Check Character Output Status, when added to the symbol, provides additional data security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character.
Note: With Check Character Output Status enabled and an External Edge, External Level, or Serial Data trigger option enabled, an invalid check character calculation will cause a No Read Message to be transmitted at the end of the read cycle.
Large Intercharacter Gap Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. When enabled, the imager can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.
Important: Do not use Large Intercharacter Gap with Narrow or Narrow, Enhanced Quiet Zone enabled, because a large intercharacter gap (over 3x) could cause a narrow quiet zone (5x) to be interpreted as an intercharacter gap. QX Hawk Industrial Imager User Manual
5-67
Page 166
Symbologies
Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid.
Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the imager will recognize (this does not include start and stop and check character characters). The imager ignores any symbology that does not match the specified length.
Full ASCII Set Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the imager can read the full ASCII character set, from 0 to 255.
5-68
QX Hawk Industrial Imager User Manual
Page 167
Parameters
Code 128 Code 128 is a smaller symbology useful in applications with limited space and high-security requirements. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.
Fixed Symbol Length Status When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered a valid symbol.
Symbol Length Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the imager will recognize (this does not include start, stop, and check character characters). The imager ignores any symbol not having the specified length.
QX Hawk Industrial Imager User Manual
5-69
Page 168
Symbologies
EAN Status When this field is disabled, the imager will not check any Code 128 labels for conformance to EAN requirements, or perform any special formatting. When enabled, the imager can read symbols with or without a function 1 character in the first position. If a symbol has a function 1 character in the first position, it must conform to EAN format. Symbols that conform to EAN format will also be subject to the special output formatting options available in this command. If EAN status is required, the imager will only decode symbols that have a function 1 character in the first position and that conform to EAN format. All symbols read will be subject to the special output formatting options available in this command.
Note: Code 128 status must be enabled for EAN status to be active.
Output Format In Standard, the imager will not apply special EAN output formatting options. In Application, the imager will apply the special EAN output formatting options to decoded EAN-conforming symbols.
5-70
QX Hawk Industrial Imager User Manual
Page 169
Parameters
Application Record Separator Status When enabled, an EAN separator will be inserted into the output between fields whenever an EAN-conforming symbol is decoded and EAN output formatting applies.
Application Record Separator Character This is an ASCII character that serves as an EAN separator in formatted EAN output.
Application Record Brackets If an EAN-conforming symbol is decoded and EAN formatting applies, this feature places bracket characters around the application identifiers in the formatted output.
Application Record Padding This feature causes the imager to pad variable-length application fields with leading zeroes. This is not done for the last field of a symbol.
QX Hawk Industrial Imager User Manual
5-71
Page 170
Symbologies
BC412
Check Character Output Status Disabled The imager will strip the verified check digit from the symbol data.
Enabled The imager will format the verified check digit as part of the symbol data.
Fixed Symbol Length Status Disabled The imager will accept any length BC412 symbol as valid.
Enabled The imager will reject any BC412 symbol that does not match the fixed code length value for BC412.
Fixed Symbol Length The code length used to validate BC-412 symbols if the fixed code length status is set to enabled.
5-72
QX Hawk Industrial Imager User Manual