Page 151
Parameters
Decodes Before Output Decodes Before Output specifies the number of times a symbol needs to be decoded before symbol data is output and a good read is declared.
QX Hawk Industrial Imager User Manual
5-53
Page 152
Read Cycle
End of Read Cycle The read cycle is the time during which the imager will attempt to decode a symbol. A read cycle can be ended by a timeout or a new trigger, or a combination of the two.
End of Read Cycle Mode Note: When operating in Continuous Read or Continuous Read 1 Output, the imager is always in the read cycle.
Timeout Typically used with Continuous Read 1 Output and Serial Data and Edge. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the imager to stop reading symbols and send the symbol data or No Read message when the time set in Timeout elapses (times out), if When to Output Symbol Data is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data and Edge enabled, a timeout ends the read cycle and symbol data or a No Read message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.
5-54
QX Hawk Industrial Imager User Manual
Page 153
Parameters
New Trigger New Trigger is an effective way to end a read cycle when objects move past the imager at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data and Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.
Timeout or New Trigger Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.
Last Frame Useful in applications in which the timeout duration varies.
Last Frame or New Trigger Useful in applications in which line speeds are irregular and a new object could appear before the last frame in the sequence. Last Frame or New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.
Read Cycle Timeout Read Cycle Timeout determines the duration of the read cycle.
QX Hawk Industrial Imager User Manual
5-55
Page 154
Read Cycle
Capture Mode Capture mode specifies how multiple captures are taken and managed throughout a read cycle.
Rapid Capture In a rapid capture mode one or multiple captures can taken at an interval specified by the time delay between captures parameter. In this mode the only limiting time factor is the integration and transfer timing.
Continuous Capture In continuous capture mode captures are continually taken throughout the read cycle in a multi-buffered format so that we start processing the first image while we are capturing the second. Continuous capture mode will override the pre-processing field; this improves performance in the multi-buffered format. This mode operation as laser scanners have historically operated, with captures spanning the entire read cycle duration until an exit condition occurs such as qualification or timeout.
Number of Captures Specifies the number of captures to process in the rapid capture mode. This parameter is used in conjunction with the time delay between captures parameters to specify the capture sequence of a rapid capture read cycle.
Rapid Capture Mode
5-56
QX Hawk Industrial Imager User Manual
Page 155
Parameters
Timed Capture Capture events are controlled by the timing values entered in the “Capture Time” command.
Triggered Capture When set to trigger captures mode the imager operates in the following manner: • The number of captures represents the number of triggers expected from the system per read cycle. The first trigger enters the read cycle. • Subsequent triggers initiate captures in the read cycle up to the number of captures is met or the end of read cycle condition is met. Any additional triggers between reaching the number of captures and meeting the end of read cycle requirements will be ignored. • If the read cycle is fully qualified prior to reaching the number of captures and the symbol output is set to ASAP, the symbol data will be output and all post processing (Logic outputs, video, etc.) will finish but the imager will remain in the read cycle. When enough triggers come in to satisfy the number of captures setting or a timeout expires, the imager will exit the read cycle. This operation would be synonymous with level triggered read cycle waiting for the trigger to fall. • If the end of read cycle is set for new trigger and the read cycle qualifications have not been met, the read cycle will exit upon receiving the first trigger after reaching the number of captures setting. At this time the post processing from the read cycle will complete and a new read cycle will begin.
QX Hawk Industrial Imager User Manual
5-57
Page 156
Read Cycle
Capture Time This command specifies the frame delays associated with the frames captured in a rapid capture mode of operation.
Time Before 1st Capture This value specifies the delay from the trigger to the first capture of any triggered read cycle.
Time Between Captures 1-2 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Time Between Captures 2-3 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Time Between Captures 3-4 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Time Between Captures 4-5 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Time Between Captures 5-6 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
5-58
QX Hawk Industrial Imager User Manual
Page 157
Parameters
Time Between Captures 6-7 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Time Between Captures 7-8 This value specifies the delay to wait before starting a frame capture for the next capture in the rapid capture sequence.
Notes for Rapid Capture, Timed Capture If rapid capture is configured for timed captures this delay is measured from the point at which the previous delay expired. If the delay expires during a previous capture the start of the capture will occur as soon as the previous capture or captures complete. For example, if rapid capture is configured for 8 captures and all delays are configured for zero all 8 captures will occur back to back as fast as the imager is able.
Notes for Rapid Capture, Triggered Capture If rapid capture is configured for triggered captures mode the delay taken is measured from the point at which the trigger for that capture is received. Also if an incoming trigger occurs before a previous delay has expired, the previous capture is initiated and the delay for the incoming trigger is started. Important: If the unit is triggered to capture more than 8 images the unit will repeat the last delay (8th) for the remaining frames.
QX Hawk Industrial Imager User Manual
5-59
Page 158
Read Cycle
Store No Read Image Image storage allows the user to store images from separate read cycles and has the ability to retrieve them later. The number of available slots for storage depends on the mode of operation. If functioning in the rapid capture mode the number of images available to store is the maximum Number of Captures – the current setting for number of captures. If the user is operating in a continuous capture mode then they can store up to the maximum number of captures – 3.
Image Storage Type Disabled / Clear Upon selection, all saved images will be cleared, and the unit will not store images for later retrieving.
Store on No Read The unit will store an image upon exiting the read cycle that retrieved a later time. If multiple captures are present during the duration of a read cycle the image stored will be the last image processed for the read cycle. This image is stored in RAM and can be retrieved as long as power is applied and the unit has not been reset via reset/save sequences. Other commands that can initialize the storage RAM are ones that changed capture modes or put the unit in a test capture mode.
Image Storage Mode First Image In this mode the image storage will store images until the available image memory has been filled. At this point the unit will stop saving additional images. In this mode you will always have the first images that were stored.
Last Image In this mode the image storage will continue to store images after the available memory has been filled by purging the oldest image in the storage memory. In this mode you will always have the last images that were stored.
5-60
QX Hawk Industrial Imager User Manual
Page 159
Parameters
Image Processing Settings Number of Symbols in Field of View Any Number of Symbols No limit on number of symbols attempted to decode in an image frame.
One Symbol Only one symbol will be decoded in an image frame, and this will be regardless of any qualifying attributes associated with the read cycle.
Image Processing Timeout Specifies the maximum amount of time allowed for image processing to spend on a captured image. When the time-out expires, the image processing is aborted. This time-out works in both rapid capture and continuous capture modes, as well as with the configuration database.
Notes: The time-out period does not include capture time. If a time-out occurs the image will be recorded as a No Read. This may cause some confusion because the image may decode fine given enough time.
QX Hawk Industrial Imager User Manual
5-61
Page 160
Symbologies
Symbologies Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Symbologies tab to display the Symbologies tree control.
To open nested options, single-click the +.
The * indicates that the setting is the default. To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Symbologies settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the 6\PERORJLHV section of Appendix E.
5-62
QX Hawk Industrial Imager User Manual