The text of a manual · part 15 of 46
QX Hawk Industrial Imager User Manual, pages 141 to 150
Pages 141 to 150 of 460
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX Hawk 6801
Page 141
Parameters
Read Cycle Setup Setting up read cycle and triggering parameters involves a series of decisions based on the particular application, as follows: 1. Select the number of symbols to be read in a single cycle. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either External Level or External Edge. 3. Designate how the read cycle should end (Timeout, New Trigger).
QX Hawk Industrial Imager User Manual
5-43
Page 142
Read Cycle
Multisymbol Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows one trigger to pick up all the symbols. Multisymbol allows the user to define up to 100 symbols that can be read in a single read cycle. The following conditions apply: • The maximum number of characters in a read cycle is 3,000 for all symbols. • All No Read messages are posted at the end of the data string, unless output filtering is enabled. • If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. • If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
Number of Symbols Number of Symbols is the number of different symbols that can be read in a single read cycle.
Multisymbol Separator Multisymbol Separator is used to delimit or separate data fields with a user-defined character. The Multisymbol Separator can be any valid ASCII character, inserted between each symbol read when Number of Symbols is set to any number greater than 1.
5-44
QX Hawk Industrial Imager User Manual
Page 143
Parameters
Trigger The Trigger is the event that initiates a read cycle. Note: When calibrating the imager or testing read rate, the current trigger setting will be disregarded.
Trigger Mode Continuous Read Continuous Read is useful in testing symbol readability or imager functions. It is not recommended for normal operations. In Continuous Read, trigger input options are disabled, the imager is always in the read cycle, and it will attempt to decode and transmit data for every symbol. If a single symbol stays within read range for multiple read cycles, its data will be transmitted repeatedly until it leaves the read range. The imager sends replies to serial commands that require responses when symbol data is transmitted, or read cycle timeout is enabled and a timeout occurs. Depending on the combination of enabled symbologies and the Threshold Mode setting, the imager may take longer than the timeout to process symbol data.
Note: When to Output and No Read options have no affect on Continuous Read.
QX Hawk Industrial Imager User Manual
5-45
Page 144
Read Cycle
Continuous Read 1 Output Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are presented by hand. In Continuous Read 1 Output the imager self-triggers whenever it decodes a new symbol or a timeout occurs. If End of Read Cycle Mode is set to Timeout and the symbol doesn’t change, the output is repeated at the end of each timeout period. For example, if Timeout is set to one second, the imager sends the symbol data immediately and repeats the output at intervals of one second for as long as the symbol remains in the field of view. If End of Read Cycle Mode is set to New Trigger, the imager will send the current symbol data immediately, but only once. A new symbol appearing in the imager’s range will be read and sent immediately, provided it is not identical to the previous symbol. Caution: In automated environments, Continuous Read 1 Output is not recommended because there is typically no reliable way to verify that a symbol was missed. Note: If Trigger Mode is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
5-46
QX Hawk Industrial Imager User Manual
Page 145
Parameters
External Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.
This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the imager spends reading each object is not predictable. It also allows the user to determine if a No Read has occurred. External Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle persists until the object moves out of the sensor range and the active trigger state changes again. Important: Level and Edge apply to the active logic state (Negative or Positive) that exists while the object is in a read cycle, between the rising edge and the falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. This applies both to External Level and External Edge.
External Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.
This mode is highly recommended in any application where conveying speed is constant, or if spacing, object size, or read cycle timeouts are consistent. External Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output, or, depending on the End of Read Cycle Mode setting, a timeout or new trigger occurs.
QX Hawk Industrial Imager User Manual
5-47
Page 146
Read Cycle
Serial Data Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the field of view. It is also useful in determining if a No Read has occurred. In Serial Data, the imager accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside angle brackets, as shown here: <n>. Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
Serial Data and Edge Serial Data and Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be triggered manually. An auxiliary terminal can be connected to the auxiliary port so the user can send the serial trigger character through the imager to the host. In this mode the imager accepts either a serial ASCII character or an external trigger pulse to start the read cycle. Note: In Serial Data, sending a non-delimited start serial character will start a read cycle; however, a non-delimited stop serial character has no effect.
Trigger Filter Duration Note: Trigger filter ranges from 32.0 µs to 2.10 seconds.
Leading Edge Used to ignore accidental triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the leading edge is filtered such that on an active edge, the state must be held interrupted for the trigger filter duration before a trigger will occur. Note: 313 = ~10ms.
5-48
QX Hawk Industrial Imager User Manual
Page 147
Parameters
Trailing Edge Used to ignore accidental triggers when Trigger Mode is set to External Edge or External Level. To consider a change in state on the trigger input, the level must be stable for the trigger filter duration. In an edge mode, the imager will trigger a read cycle if the active state has been uninterrupted for the entire trigger filter duration. In a level mode, the trailing edge is filtered such that on the falling edge, the state must be held for the trigger filter duration before the trigger will be deemed inactive. Note: 313 = ~10ms.
External Trigger State Allows users to select the trigger polarity that will be used in their application. Determines the active state of the trigger signal applied to the cable input of the imager.
QX Hawk Industrial Imager User Manual
5-49
Page 148
Read Cycle
Serial Trigger Allows the user to define the trigger character and delimiters that start and stop the read cycle. A serial trigger is considered an online host command and requires the same command format as all host commands. It must be entered within angle bracket delimiters < and > or, in the case of non-delimited triggers, it must define individual start and stop characters.
Character (Delimited) Allows the user to define the trigger character that initiates the read cycle. A single ASCII character, including control characters. Note: The following characters cannot be used as serial trigger characters: NUL (0x00), an existing host command character, or an online protocol character. A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < and >.
Note: Serial Data or Serial Data and Edge trigger mode must be enabled for Serial Trigger Character to function.
5-50
QX Hawk Industrial Imager User Manual
Page 149
Parameters
Start Character (Non-Delimited) Useful in applications where different characters are required to start a read cycle. A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Start characters can be defined and will function according to the trigger event. When defining Start trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle.
QX Hawk Industrial Imager User Manual
5-51
Page 150
Read Cycle
Stop Character (Non-Delimited) Useful in applications where different characters are required to end a read cycle. A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >. Non-delimited Stop characters can be defined and will function according to the trigger event. When defining Stop trigger characters, the following rules apply: • In External Edge the imager looks only for the Start trigger character and ignores any Stop trigger character that may be defined. • In External Level the Start trigger character begins the read cycle and the Stop trigger character ends it. Note that even after a symbol has been decoded and the symbol data transmitted, the imager remains in External Level trigger read cycle until a Stop character is received. • In Serial Data and Edge trigger mode, either a Start trigger character or a hardware trigger can start an edge trigger read cycle.
5-52
QX Hawk Industrial Imager User Manual