Page 131
Parameters
Full Duplex Mode When Full Duplex Mode is enabled, the following conditions apply: Symbol Data to Source = Fixed to Disabled Ambles to Source = Fixed to Disabled Echo to Source = Fixed to Disabled Output at End of Read Cycle = Fixed to Disabled Output at ETX = Fixed to Disabled with user-defined characters. Default character will be used if this setting is set to Disabled. Output at Timeout = Fixed to Disabled with user-defined timeout. Default time will be used if this setting is set to Disabled. Mode of Operation • Source Port data is not echoed back to itself. • Source Port data is ignored when the Destination Port is in Polling Mode. • Source Port data or symbol data is sent to the Destination Port whenever it is received. • Source Port data is always sent to the Destination Port without a Preamble or Postamble. • Symbol data is not sent to the Source Port. • Destination port data is echoed to the source port in an un-polled mode.
Custom Mode Custom allows for user-defined communication (Ambles to Source, Echo to Source, Output at End of Read Cycle, Output at ETX, Output at Timeout).
QX Hawk Industrial Imager User Manual
5-33
Page 132
Communication
Destination Port Determines the port to which data will be sent.
Ambles to Source Enables or Disables the ability to send Preambles and Postambles to the Source port.
Echo to Source Enables or Disables the ability to send an Echo to the Source port.
Output at End of Read Cycle Enables or Disables the ability to output data at the end of read cycle.
5-34
QX Hawk Industrial Imager User Manual
Page 133
Parameters
Output at ETX Determines the output at ETX.
Output at Timeout Determines the Timeout value for output.
QX Hawk Industrial Imager User Manual
5-35
Page 134
Communication
Array Communication Modes
Mode Daisy Chain When set to Daisy Chain, follows Microscan Daisy Chain protocol. Note: Daisy Chain can also be autoconfigured by sending the Daisy Chain Autoconfigure serial command.
Source Defines the communication port.
Daisy Chain ID Status When enabled, the imager will append a two-character prefix to each imager in the array. This allows the user to identify which imager sent the data. Note: Daisy Chain ID will automatically disable Symbol Data Output, Extended Data, and Diagnostics Output for the Source Port. Symbol Data Output will be automatically enabled, Extended Data will be automatically enabled, and Diagnostics Output will be automatically disabled for the Destination Port.
5-36
QX Hawk Industrial Imager User Manual
Page 135
Parameters
Daisy Chain ID The Daisy Chain ID is a two-character identifier.
QX Hawk Industrial Imager User Manual
5-37
Page 136
Communication
Daisy Chain Autoconfigure For quick setup of a daisy chain configuration. The command to Autoconfigure the daisy chain is sent to the primary imager and the software responds in the following ways: • Counts the number of secondary imagers in the daisy chain. • Assigns an internal ID number (1...n) to each secondary imager, where the first secondary imager is number 1 (the primary imager’s ID being a 0). • Propagates the communication settings and the relevant operating modes of the primary imager to the ports of each secondary imager. • Resets each secondary imager. • Confirms that each secondary imager has acquired the new settings. When setting up a daisy chain operation, perform the following steps: 1. Set the primary imager (the one connected to the host) to Serial Data Trigger Mode. This will also set all the imagers in the chain to Serial Data when the command is executed. Important: All secondary imagers must be set to Serial Data Trigger Mode for Daisy Chain to function. Before Autoconfigure, the primary imager must be set to Serial (S): Host
S
Primary Imager
S
Secondary Imager 1
S
Secondary Imager 2
2. Send the <K150DAISY> command from ESP’s Terminal. 3. If necessary, set the primary imager to External Edge. After Autoconfigure, the primary imager can be set to External Edge (E), but the other imagers must remain in Serial (S): Host
E
Primary Imager
S
Secondary Imager 1
S
Secondary Imager 2
Pre-Setup Requirements: 1. Start setup by matching the communication settings of the “downstream” port of the primary imager to the “upstream” ports of the secondary imagers. It may be necessary to set up all the “upstream” ports first so the chain can pass information. 2. “Downstream” ports on secondary imagers will be set up automatically during the setup process. 3. If the imager is Ethernet-enabled, first check to determine if RS-232 B is available. If it is available, set RS-232 B as the Source port in Array Communication Modes. Otherwise, set RS-232 A as the Source port. Port Routing for Symbol Data Output and Extended Data will be disabled on the Source port.
5-38
QX Hawk Industrial Imager User Manual
Page 137
Parameters
Daisy Chain Considerations Settings for Number of Symbols and Timeout must be taken into consideration when setting up a daisy chain configuration. An example of a three-imager daisy chain configuration and the associated Number of Symbols and Timeout settings is shown here. Sample setup of three imagers, each with one symbol in its field of view: > Secondary Imager 2 > Secondary Imager 1 > Primary Imager > Host # of Symbols = 1 # of Symbols = 2 # of Symbols = 3 Timeout = 100 ms Timeout = 200 ms Timeout = 300 ms
Number of Symbols For each imager in the chain, the number of symbols set must equal the number of symbols in the current imager’s own field of view plus the number of symbols in the previous imager’s field of view. (The last imager in the chain – Secondary Imager 2 in this example – only needs to be set for the number of symbols in its own field of view, as there is no previous imager.) For example, if there are three imagers and each imager has one symbol in its field of view, the number of symbols for each imager should be set as follows: • Secondary Imager 2: # of Symbols = 1 • Secondary Imager 1: # of Symbols = 2 • Primary Imager: # of Symbols = 3 If there are two symbols in Secondary Imager 2’s field of view, one symbol in Secondary Imager 1’s field of view, and two symbols in the Primary Imager’s field of view, the number of symbols for each imager should be set as follows: • Secondary Imager 2: # of Symbols = 2 • Secondary Imager 1: # of Symbols = 3 • Primary Imager: # of Symbols = 5
Timeout The last imager in the chain passes its symbol data back in the direction of the host when its timeout expires. Each imager must have its timeout set to acommodate its own read time plus the read time of the previous imager. For example, if it is determined that a maximum of 100 ms is adequate for each imager to decode its associated symbol(s), the timeout for each imager should be set as follows: • Secondary Imager 2: Timeout = 100 ms • Secondary Imager 1: Timeout = 200 ms • Primary: Timeout = 300 ms
QX Hawk Industrial Imager User Manual
5-39
Page 138
Communication
Preamble Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.
Preamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data
5-40
QX Hawk Industrial Imager User Manual
Page 139
Parameters
Postamble Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.
Postamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data.
QX Hawk Industrial Imager User Manual
5-41
Page 140
Read Cycle
Read Cycle Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Read Cycle tab to display the Read Cycle tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Read Cycle settings can also be sent to the imager from ESP’s Terminal using Microscan’s K command format. Refer to the Read Cycle section of Appendix E.
5-42
QX Hawk Industrial Imager User Manual