Page 211

Parameters

EZ Button Status

Disabled When set to Disabled, the EZ Button does not function.

Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Modes command.

Trigger When selected, the EZ Button acts as a trigger for the imager to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:

The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and End of Read Cycle Mode is set to Timeout. As with External Level, External Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike External Level, the read cycle ends with a good read output, a timeout, or a new trigger.

Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.

Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.

QX Hawk Industrial Imager User Manual

5-113

Page 212

I/O Parameters

Default on Power-On When enabled, if the EZ Button is held down on power-on, the imager will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command from ESP’s Terminal.

Load Configuration Database Loads Configuration Database settings to the imager.

Save for Power-On Saves imager settings for Power-On.

5-114

QX Hawk Industrial Imager User Manual

Page 213

Parameters

EZ Button Modes Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 7 modes.

Single Beep Hold down button until a single beep is heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System (Default) When the imager reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

QX Hawk Industrial Imager User Manual

5-115

Page 214

I/O Parameters

Two Beeps Hold down button until two beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate (Default) Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the imager reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

5-116

QX Hawk Industrial Imager User Manual

Page 215

Parameters

Three Beeps Hold down button until three beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate (Default) Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the imager reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

QX Hawk Industrial Imager User Manual

5-117

Page 216

I/O Parameters

Four Beeps Hold down button until four beeps are heard. Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibrate Calibrate is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On (Default) All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Target System When the imager reaches this position, the targeting pattern appears. The targeting pattern remains illuminated even if a different position is subsequently selected until this position selection is disabled. To turn the targeting pattern off, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

5-118

QX Hawk Industrial Imager User Manual

Page 217

Parameters

Status Indicators The QX Hawk features an array of LEDs that indicate various aspects of imager activity.

Controls the operation of the MOD/ACT and NET/LNK LEDs.

Disabled When set to Disabled, the MOD/ACT and NET/LNK LEDs are always off. Note: All green and red LEDs will turn on briefly during power-on or reset to confirm that they are functioning.

PHY Activity If Ethernet is available: LNK = Solid green when transceiver is linked. ACT = Blinking green when transceiver detects Tx or Rx activity. Otherwise, for all RS-232 and RS-422/485 activity: LNK = Blinking green with Tx data activity. ACT = Blinking green with Rx data activity. Note: Red is never turned on.

Protocol Activity If EtherNet/IP is enabled: MOD = Module status, per EtherNet/IP specification NET = Network status, per EtherNet/IP specification Otherwise, the MOD and NET LEDs are always off.

QX Hawk Industrial Imager User Manual

5-119

Page 218

I/O Parameters

Bar Graph Read Rate, Auto Calibration, Bar Code Configuration, and Read Cycle Result all share the Bar Graph (20% – 100%) LEDs.

I/O 1 I/O 1 always shows the combined state of the discrete outputs. If any output is active, the I/O 1 LED will be on.

I/O 2 I/O 2 always shows the state of the hardware input trigger. If the trigger is active, I/O 2 will be on.

5-120

QX Hawk Industrial Imager User Manual

Page 219

Parameters

Calibration Options This command specifies the operation of the calibration feature. The default configuration is setup to perform calibration on gain, focus and symbol type. Shutter speed is disabled as the default setting, since shutter speed is more of an application specific parameter and normally should be configured by the user to meet the requirements of the application. The calibration process will optimize the gain setting for the configured shutter speed (Camera). Note: Background color (Reverse Video) is part of the calibration process, regardless of the calibration setup. After successful completion of calibration, the background color will be set to the appropriate value depending on the calibrated symbol. The mirrored image parameter is not part of the calibration process, and must be configured appropriately by the user prior to calibration (Mirrored Image).

Gain Disabled The gain is fixed and is not part of the calibration process.

Enabled The gain will be calibrated to provide the best image quality and performance.

QX Hawk Industrial Imager User Manual

5-121

Page 220

I/O Parameters

Shutter Speed Unless an application is a static setup, the shutter speed setting should be configured by the user based on their application. For dynamic applications the user should configure the shutter speed setting, so the calibration process can optimize the gain for that setting. The following table illustrates a general guide-line for shutter speed configurations for various line speeds. Note: This is a general guide line, and depends on the scanners optical configuration and symbol element size.

Don’t Calibrate The shutter speed is fixed and is not part of the calibration process.

Calibrate The shutter speed will be calibrated to provide the best image quality and performance.

Calibrate Fast Shutter The calibration process will concentrate on achieving the fastest possible shutter setting that still will still have good performance. The image quality or contrast may not be as good as what would be achieved with the “Enabled” setting. The calibration process is not designed to choose the fastest shutter speed that can decode a symbol, but rather to optimize for the fastest shutter speed that still provides good image quality.

5-122