Page 11
Quick Start
QX Hawk C-Mount Item
Description
Part Number
1
QX Hawk C-Mount Industrial Imager
FIS-6801-XXXXG
2
QX-1 Interface Device
98-000103-02
3
Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m
61-000162-02
4
Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m
61-000152-02
5
Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m
61-000153-02
6
Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket
97-000012-01
7
Cordset, Host, Ethernet, M12 8-pin Plug (Ultra-Lock) to RJ45, 1 m
61-000160-01 or
Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m
61-000160-02
8
Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m
99-000020-02
9
Cordset, Smart Series Light to QX-1, ON/OFF (not shown)
61-000207-01
Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.
Note: The QX Hawk C-Mount does not require an Ethernet crossover cordset, because the imager itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02). Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain. 1
1
7 3
5
3
2
2
6
6
8
Serial Standalone (with QX-1)
8
Ethernet Standalone (with QX-1)
Hardware Required Caution: Be sure that all connections are secure BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
QX Hawk Industrial Imager User Manual
1-3
Page 12
Connect the System
Step 2, Connect the System Standard QX Hawk Important: When connecting Ultra-Lock cordsets to the QX Hawk and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain.
RS-232 • Connect the Serial Communication Cable from “A” on the QX Hawk to “2” on the QX-1. • Connect the host cable from “1” on the QX-1 to the host computer. • Connect the photo sensor to “T” on the QX-1. • Connect the power supply to “3” on the QX-1. • Plug in the power supply.
Ethernet Note: The QX Hawk does not require an Ethernet crossover cordset, because the imager itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02). • Connect the Ethernet Cable from “B” on the QX Hawk to the network. • Connect the photo sensor to “T” on the QX-1. • Connect the power supply to “A” on the QX Hawk. • Plug in the power supply. 1
1
7 3
5 2
2
6
8
Serial Standalone (with QX-1) 1-4
3
6
8
Ethernet Standalone (with QX-1) QX Hawk Industrial Imager User Manual
Page 13
Quick Start
QX Hawk C-Mount Important: When connecting Ultra-Lock cordsets to the QX Hawk C-Mount and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain.
RS-232 • Connect the Serial Communication Cable from “A” on the QX Hawk C-Mount to “2” on the QX-1. • Connect the host cable from “1” on the QX-1 to the host computer. • Connect the photo sensor to “T” on the QX-1. • Connect the power supply to “3” on the QX-1. • Plug in the power supply.
Ethernet Note: The QX Hawk C-Mount does not require an Ethernet crossover cordset, because the imager itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02). • Connect the Ethernet Cable from “B” on the QX Hawk C-Mount to the network. • Connect the photo sensor to “T” on the QX-1. • Connect the power supply to “A” on the QX Hawk C-Mount. • Plug in the power supply. 1
1
7 3
5 2
3 2
6
8
Serial Standalone (with QX-1)
QX Hawk Industrial Imager User Manual
6
8
Ethernet Standalone (with QX-1)
1-5
Page 14
Position the Imager
Step 3, Position the Imager • Position the imager at a focal distance of one inch or more from a test symbol. • Tip the imager relative to the symbol if necessary to avoid the glare of direct (specular) reflection. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the field of view. In the case of linear symbols, aligning the bars in the direction of their movement (ladder orientation) will minimize the chances of blurring and will result in more consistent decodes.
Standard QX Hawk Imager and Symbol Orientation
QX Hawk C-Mount Imager and Symbol Orientation Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°.
1-6
QX Hawk Industrial Imager User Manual
Page 15
Quick Start
Step 4, Install ESP ESP Software can be found on the Microscan Tools Drive. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
Minimum System Requirements • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended)
QX Hawk Industrial Imager User Manual
1-7
Page 16
Select Model
Step 5, Select Model Standard QX Hawk When you start ESP, the model menu will appear:
1. Click the button showing the QX Hawk. 2. Click OK. Note: You can also simply double-click the button showing your imager to make your selection. 3. Click Yes when the following dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. 1-8
QX Hawk Industrial Imager User Manual
Page 17
Quick Start
QX Hawk C-Mount When you start ESP, the model menu will appear:
1. Click the button showing the QX Hawk C-Mount. 2. Click OK. Note: You can also simply double-click the button showing your imager to make your selection. 3. Click Yes when the following dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.
QX Hawk Industrial Imager User Manual
1-9
Page 18
Connect
Step 6, Connect Connection Wizard To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select RS-232 or Ethernet to activate the appropriate display. • Configure settings as required by the application, and click Connect.
RS-232 Connection Wizard
Ethernet Connection Wizard
• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
Important: The imager is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the imager’s field of view while attempting to connect.
1-10
QX Hawk Industrial Imager User Manual
Page 19
Quick Start
Step 6, Connect (cont.) Ethernet TCP/IP Once the QX Hawk is connected, incoming symbol data can be displayed in the Terminal, as shown below.
QX Hawk Industrial Imager User Manual
1-11
Page 20
Locate Symbol
Step 7, Locate Symbol Locate by ESP • In ESP’s EZ Mode, click the Locate button to enable the red X pattern.
The symbol in the field of view will appear in the video view beneath the Locate and Calibrate buttons, and you will see the red target pattern projected from the front of the imager. Note: The QX Hawk C-Mount does not display a target pattern. • Center the target pattern on the symbol.
Important: The entire symbol should fall within the field of view (FOV) of the imager. The field of view is what appears in ESP’s Locate/Calibrate window in EZ Mode. • Click the Stop button to end the Locate function.
1-12
QX Hawk Industrial Imager User Manual