Page 21
Quick Start
Locate by EZ Button If you are not connected to a host computer, the EZ Button allows you to locate a symbol in the imager’s field of view.
EZ Button
• Hold down the EZ Button for about one second and release when you hear one short beep. The amber 20% LED will illuminate, and you will see the red target pattern projected from the front of the imager. • Center the target pattern on the symbol. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
QX Hawk Industrial Imager User Manual
1-13
Page 22
Calibrate
Step 8, Calibrate Imager settings can be adjusted automatically for optimum performance by either the EZ Button or by ESP. During the calibration routine, the imager will flash its amber Read Rate percent LEDs and illumination LEDs while searching camera settings and determining the best configuration for decoding symbol data. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the imager will emit 5 short beeps and stop searching.
Calibrate by ESP 1. Click the Calibrate button.
2. The imager will search camera settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol data will be presented in the field below the image display window.
Calibrate by EZ Button 1. Hold down the EZ Button for about two seconds and release when you hear two short beeps. The 20% and 40% LEDs will illuminate. 2. The imager will search camera settings to determine the best configuration for decoding symbol data. Note: To end all EZ Button functions, press the EZ Button once and quickly release.
Calibrate by Serial Command Send <@CAL> from a terminal program to begin auto-calibration. 1-14
QX Hawk Industrial Imager User Manual
Page 23
Quick Start
Step 9, Test Read Rate Read Rate indicates the number of successful decodes per second achieved by the imager.
Test Read Rate by ESP 1. Click the Test button to start the Read Rate test.
If a symbol has been successfully decoded, its data and related information will be presented in the field below the image display window. While the symbol is being decoded, the Read Rate LEDs will indicate the corresponding read rate percentage on the top of the unit. 2. Click the Stop button to end the Read Rate test. Note: Read rate can also be tested using the Read Rate interface in Utilities.
Test Read Rate by EZ Button 1. To start the Read Rate test, hold down the EZ Button about three seconds until you hear three short beeps. The 20%, 40%, and 60% LEDs will illuminate. While the symbol is being decoded, the Read Rate LEDs will indicate the corresponding read rate percentage on the top of the unit.
100% EZ Button
80% 60% 40% 20%
These LEDs represent the percentage of Good Reads per images captured.
2. To end the Read Rate test, press the EZ Button and quickly release.
Test Read Rate by Serial Command You can also start a test with the <C> or <Cp> command and end it with the <J> command.
QX Hawk Industrial Imager User Manual
1-15
Page 24
Configure the Imager
Step 10, Configure the Imager Click the App Mode button to make configuration changes to the imager.
The following modes are accessible by clicking the buttons at the top of the screen:
• Click the EZ Mode button to return to EZ Mode. • Click the Autoconnect button to establish communication. • Click the Send/Recv button to send or receive commands. • Click the Switch Model button to open the model menu, or to return to a previous model. • Click the Parameters button to show the tabbed tree controls for Communication, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics. • Click the Setup button to access the Camera Setup tree control and the tabbed interfaces for Video, Evaluation, Calibration, Window of Interest (WOI), Configuration Database, Ordered Output, Output Format, and Dynamic Setup. • Click the Terminal button to display decoded symbol data and to send serial commands to the imager using text or macros. • Click the Utilities button to show the tabbed interfaces for Read Rate, Counters, Device Control, Differences from Default, Master Database, and Firmware. For further details, see ESP Help in the dropdown Help menu.
1-16
QX Hawk Industrial Imager User Manual
Page 25
Quick Start
Step 11, Save Changes To make changes to configuration settings in the tree controls:
1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options. 3. Place the cursor in 4. Left-click again on the the selection box, open screen to complete scroll down to the the selection. setting you want to change, and click once on the setting.
5. Right-click on the open screen and select Save to Reader to implement the command in the imager.
Saving Options • Send, No Save. Changes will be lost when power is re-applied to the imager. • Send and Save. This activates all changes in current memory and saves to the imager for power-on.
QX Hawk Industrial Imager User Manual
1-17
Page 26
Save Changes
1-18
QX Hawk Industrial Imager User Manual
Page 27
2 Using ESP Contents EZ Mode........................................................................................................................................2-2 App Mode......................................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 Navigating in ESP .......................................................................................................................2-15 Send/Receive Options ................................................................................................................2-16
This section explains the basic structure and elements of ESP (Easy Setup Program). When ESP is opened, unless otherwise specified in ESP Preferences, the EZ Mode view will appear. App Mode contains several tree controls (Communication, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics), a Setup interface, a Terminal interface, and a Utilities interface. ESP can be used to configure the QX Hawk in three different ways: • Graphic User Interfaces: Imager settings can be configured using such point-and-click tools as buttons, spin boxes, check boxes, and drag-and-drop functions. • Tree Controls: Each tree control contains a list of all command settings that pertain to that specific area of imager operation. Each parameter can be configured using dropdown menus or fields where characters can be entered. • Terminal: ESP’s Terminal allows the user to send serial configuration and utility commands directly to the imager by typing them in the provided field. Information about using specific commands in ESP is provided in subsequent sections. For ESP system requirements, see Minimum System Requirements in Chapter 1, Quick Start.
QX Hawk Industrial Imager User Manual
2-1
Page 28
EZ Mode
EZ Mode EZ Mode allows the user to test read rate and calibrate the imager. After connecting to the imager, the EZ Mode view will appear. On-screen instructions assist the user with positioning, testing, and calibration.
Locate/Calibrate/Learn The calibration routine optimizes the imager by comparing Read Rates at various camera and image processing settings. Click Locate to find the symbol in the field of view and display it in the video view. Then click Calibrate to begin the calibration routine. The Learn button allows you to save information about the next Data Matrix symbol decoded, which allows faster and more consistent processing of subsequent identical symbols.
Test Click the Test button to start the Read Rate test for a quick indication of the imager’s read capabilities and the limits of the application. When Decodes per Second is unchecked, the test will count the percentage of decodes relative to the number of actual scans. Click Stop to end the test. Click Locate to find and display the symbol. Click Calibrate to begin the calibration routine. Calibration is also explained in Quick Start. Click Learn to save information about the next Data Matrix symbol decoded.
Click the App Mode button to access configuration trees and other setup features.
When Decodes per Second is checked, the read rate test displays how many decodes the imager achieves each second, instead of displaying a percentage.
2-2
Click here to initiate a sliding focus control.
Click Test button to start the Read Rate test and click Stop to end the test.
Symbol data is displayed here.
Contrast brightens the image.
QX Hawk Industrial Imager User Manual
Page 29
Using ESP
App Mode From EZ Mode, click on the App Mode button to access the tabbed tree controls in Parameters, the intuitive user interfaces in Setup, the Terminal interface, and the Utilities interface.
Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Video, Evaluation, Calibration, WOI, Configuration Database, Ordered Output, Output Format, Dynamic Setup Click this icon to return to EZ Mode.
Menu toolbar
Autoconnect to the imager, Send and Receive command settings, and Switch Model.
Click here to open the Terminal view.
Tabbed tree controls
Read Rate, Counters, Device Control, Differences from Default, Master Database, Firmware
Mirror Image reverses the image. Contrast brightens the image. Click Capture and Decode to decode the symbol in the field of view, and to see a high resolution image capture of the symbol. Symbol data is displayed here.
QX Hawk Industrial Imager User Manual
2-3
Page 30
Menu Toolbar
Menu Toolbar File New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When configuration changes are saved to the hard drive, these changes are not automatically saved to the imager. The illustration below shows how settings can be saved and received between ESP and the imager, and ESP and the host hard drive.
(Save to Imager) (Receive Imager Settings)
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
2-4
QX Hawk Industrial Imager User Manual