The text of a manual · part 1 of 46

QX Hawk Industrial Imager User Manual, pages 1 to 10

Pages 1 to 10 of 460

The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan QX Hawk 6801

Page 1 read from a scan by OCR; it may hold reading errors

MICROSCAN.

QX Hawk Industrial Imager User Manual

Ve J 6 an ‘ '

-_ -, is) -

MMVH XO a ~~,

= a --] (eo) ra) >

“

P/N 84-006800 Rev D

Page 2

Copyright and Disclaimer Copyright ©2015 Microscan Systems, Inc. Tel: +1.425.226.5700 / 800.762.1149 Fax: +1.425.226.8250 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. We state herein that we are using the names to the benefit of the trademark owner, with no intention of infringement.

Disclaimer The information and specifications described in this manual are subject to change without notice.

Latest Manual Version For the latest version of this manual, see the Download Center on our web site at: www.microscan.com.

Technical Support For technical support, e-mail: helpdesk@microscan.com.

Warranty For current warranty information, see: www.microscan.com/warranty.

Microscan Systems, Inc. United States Corporate Headquarters +1.425.226.5700 / 800.762.1149 United States Northeast Technology Center +1.603.598.8400 / 800.468.9503 European Headquarters +31.172.423360 Asia Pacific Headquarters +65.6846.1214 ii

QX Hawk Industrial Imager User Manual

Page 3

Introduction

Table of Contents Chapter 1

Quick Start

Step 1 Check Hardware .......................................................................... 1-2 Step 2 Connect the System ..................................................................... 1-4 Step 3 Position the Imager ...................................................................... 1-6 Step 4 Install ESP.................................................................................... 1-7 Step 5 Select Model ................................................................................ 1-8 Step 6 Connect ...................................................................................... 1-10 Step 7 Locate Symbol ........................................................................... 1-12 Step 8 Calibrate..................................................................................... 1-14 Step 9 Test Read Rate .......................................................................... 1-15 Step 10 Configure the Imager ............................................................... 1-16 Step 11 Save Changes.......................................................................... 1-17

Chapter 2

Using ESP

EZ Mode .................................................................................................. 2-2 App Mode ................................................................................................ 2-3 Menu Toolbar .......................................................................................... 2-4 Navigating in ESP................................................................................. 2-15 Send/Receive Options .......................................................................... 2-16

Chapter 3

Hardware Integration

Cordsets .................................................................................................. 3-2 QX Hawk and QX-1 Connectors and Pinouts.......................................... 3-3 Power and Trigger Switching................................................................... 3-8 Port Routing............................................................................................. 3-9 Application Examples ............................................................................ 3-10

Chapter 4

Setup

Video ....................................................................................................... 4-2 Evaluation ............................................................................................. 4-18 Calibration ............................................................................................. 4-21 Window of Interest ................................................................................. 4-22 Configuration Database ......................................................................... 4-24 Ordered Output...................................................................................... 4-33 Output Format ....................................................................................... 4-37 Dynamic Setup ...................................................................................... 4-41

Chapter 5

Parameters

Communication........................................................................................ 5-2 Read Cycle ............................................................................................ 5-42 Symbologies .......................................................................................... 5-62 I/O Parameters ...................................................................................... 5-98 Symbol Quality .................................................................................... 5-159 Matchcode ........................................................................................... 5-166 Diagnostics .......................................................................................... 5-175

QX Hawk Industrial Imager User Manual iii

Page 4

Table of Contents Chapter 6

Terminal

Terminal View.......................................................................................... 6-2 Find ......................................................................................................... 6-3 Send ........................................................................................................ 6-4 Macros..................................................................................................... 6-5 Terminal Menus....................................................................................... 6-6

Chapter 7

Utilities

Serial Utility Commands .......................................................................... 7-2 Read Rate ............................................................................................... 7-4 Counters .................................................................................................. 7-6 Device Control ......................................................................................... 7-9 Differences from Default........................................................................ 7-10 Master Database ................................................................................... 7-11 Firmware ............................................................................................... 7-17 Bar Code Configuration Mode ............................................................... 7-21 Calibration ............................................................................................. 7-22 Default/Reset/Save ............................................................................... 7-23 Imager Status ........................................................................................ 7-25 Learn Operations................................................................................... 7-27 Reboot System ...................................................................................... 7-28 Static Validation..................................................................................... 7-29 Targeting ............................................................................................... 7-31 Y-Modem Transfer Options ................................................................... 7-32 Temperature .......................................................................................... 7-34

Appendices Appendix A General Specifications .........................................................A-2 Appendix B Electrical Specifications .....................................................A-11 Appendix C Ground and Shield Considerations ....................................A-20 Appendix D Flying Lead Cordset Pinouts..............................................A-22 Appendix E Serial Commands ..............................................................A-23 Appendix F Protocol Commands...........................................................A-85 Appendix G ASCII Table .......................................................................A-94 Appendix H Configuring Ethernet TCP/IP .............................................A-95 Appendix I Using EtherNet/IP................................................................A-98 Appendix J Allen-Bradley Version 16 PLC Setup................................A-107 Appendix K Allen-Bradley Version 20 PLC Setup ...............................A-120 Appendix L EIPScan Setup .................................................................A-132 Appendix M Interface Standards .........................................................A-138 Appendix N Glossary of Terms ...........................................................A-139 iv

QX Hawk Industrial Imager User Manual

Page 5

Introduction

About the QX Hawk Industrial Imager The key features of the QX Hawk Industrial Imager are: • Standard and C-Mount versions available • Fully integrated liquid lens technology • High-resolution modular optical zoom system • Simple connectivity with M12 cordsets and connectors • Best-in-class X-Mode™ algorithms • Support for Ethernet TCP/IP and EtherNet/IP™ • A green flash, visible from all angles, to signal a successful read • LED array for performance, communication, and I/O user feedback • EZ Button for setup and testing • Compact size for easy integration into a wide variety of applications • IP65/67 enclosure

Imager Communication There are three ways to configure and test the QX Hawk: • Microscan’s ESP (Easy Setup Program), which offers point-and-click ease of use and visual responses to user adjustments. • Serial commands, such as <K100,1>, that can be sent from ESP’s Terminal or another terminal program. • The EZ Button on the top of the imager.

“EtherNet/IP” is a trademark of the Open DeviceNet Vendors Association.

QX Hawk Industrial Imager User Manual v

Page 6

Warning and Caution Summary

Warning and Caution Summary This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna; • Increase the separation between the equipment and receiver; • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; • Consult the dealer or an experienced radio/TV technician for help. For connection to a UL-listed direct plug-in power unit marked Class II and rated 10 to 28 VDC at 5 watts or greater. U.S. models must use a similarly rated Class I or Class II power supply that is certified to comply with standards for safety IEC 60950-1 Ed. 2 (2005) and IEC 60825-1 Ed. 2 (2007). European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety EN 60950-1 (2006) with Am. 11 (2009). Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser or LED light radiation exposure. There are no user-serviceable parts in the imager. Opening the imager voids the Microscan Systems, Inc. warranty.

Warning Label Placement This warning label is located on the QX Hawk Industrial Imager:

vi

QX Hawk Industrial Imager User Manual

Page 7

Introduction

Statement of Agency Compliance

The QX Hawk has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

The QX Hawk has been tested for compliance with CE (Conformité Européenne) standards and guidelines, and has been found to conform to applicable CE standards, specifically the following requirements: General Immunity for Light Industry: EN 55024:1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE Equipment: EN 55022:98 ITE Disturbances The QX Hawk has been tested by an independent electromagnetic compatibility laboratory in accordance with the applicable specifications and instructions.

QX Hawk Industrial Imager User Manual vii

Page 8

Statement of RoHS Compliance

Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF

Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.

viii

QX Hawk Industrial Imager User Manual

Page 9

1 Quick Start Contents Step 1 Check Hardware................................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-4 Step 3 Position the Imager............................................................................................................ 1-6 Step 4 Install ESP ......................................................................................................................... 1-7 Step 5 Select Model...................................................................................................................... 1-8 Step 6 Connect ........................................................................................................................... 1-10 Step 7 Locate Symbol................................................................................................................ 1-12 Step 8 Calibrate .......................................................................................................................... 1-14 Step 9 Test Read Rate ............................................................................................................... 1-15 Step 10 Configure the Imager.................................................................................................... 1-16 Step 11 Save Changes .............................................................................................................. 1-17

This section explains how to set up and test the QX Hawk quickly using ESP (Easy Setup Program). Detailed setup information for installing the imager into an application can be found in subsequent sections.

QX Hawk Industrial Imager User Manual

1-1

Page 10

Check Hardware

Step 1, Check Hardware Standard QX Hawk Item

Description

Part Number

1

QX Hawk Industrial Imager

FIS-6801-XXXXG

2

QX-1 Interface Device

98-000103-02

3

Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m

61-000162-02

4

Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m

61-000152-02

5

Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m

61-000153-02

6

Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket

97-000012-01 61-000160-01

7

Cordset, Host, Ethernet, M12 8-pin Plug (Ultra-Lock) to RJ45, 1 m or

Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m

61-000160-02

8

Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

99-000020-02

Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.

Note: The QX Hawk does not require an Ethernet crossover cordset, because the imager itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-01 or -02). Important: Do not attempt to power more than four imagers with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional imagers in the daisy chain. 1

1

7 3

5

3

2

2

6

6

8

Serial Standalone (with QX-1)

8

Ethernet Standalone (with QX-1)

Hardware Required Caution: Be sure that all connections are secure BEFORE applying power to the system. Always power down BEFORE disconnecting any cables. 1-2

QX Hawk Industrial Imager User Manual