Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 37 of 43

QX-870 Industrial Raster Scanner User Manual, pages 361 to 370

Pages 361 to 370 of 426

The original document is the PDF (7.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan QX-870

Page 361

Appendices

Match Replace Serial Cmd: Default: Options:

<K735,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled

Replacement String Serial Cmd: Default: Options:

<K735,status,replacement string> MATCH Any valid ASCII string up to 128 characters

Mismatch Replace Serial Cmd: Default: Options:

<K736,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled

Replacement String Serial Cmd: Default: Options:

<K736,status,replacement string> MISMATCH Any valid ASCII string up to 128 characters

QX-870 Industrial Raster Scanner User Manual

A-75

Page 362

Serial Commands

Diagnostics High Temperature Threshold Low Temperature Threshold Counts (Read-only) Hours Since Reset (Read-only) Service Message Laser Current Warning Message User-Defined Name

<K402,status,message> <K403,status,message> <K406> (returns: power-on,resets, power-on saves,custom default saves) <K407> (returns: hours,minutes) <K409,status,service message, threshold,resolution> <K411,laser high status,laser high message,laser low status, laser low message> <K412,user-defined name>

High Temperature Threshold Serial Cmd: Default: Options:

<K402,status,message> 0 = Disabled 0 = Disabled

1 = Enabled

Message Serial Cmd: Default: Options:

<K402,status,message> HIGH_TEMP Any valid ASCII string up to 128 characters

Low Temperature Threshold Serial Cmd: Default: Options:

<K403,status,message> 0 = Disabled 0 = Disabled

1 = Enabled

Message Serial Cmd: Default: Options:

<K403,status,message> LOW_TEMP Any valid ASCII string up to 128 characters

Counts (Read-only) Power-On Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments on scanner power-on.

Resets Serial Cmd:

A-76

<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments on scanner reset. Value is reset on power-on.

QX-870 Industrial Raster Scanner User Manual

Page 363

Appendices Power-On Saves Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments when a scanner setting is saved for power-on (<Z> command).

Custom Default Saves Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments when a scanner setting is saved to the customer parameter section of flash memory (<Zc> command).

Hours Since Reset (Read-only) Hours Serial Cmd:

<K407,hours,minutes> 16-bit counter (0 to 65535)

Minutes Serial Cmd:

<K407,hours,minutes> 16-bit counter (0 to 60)

Service Message Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> 0 = Disabled 0 = Disabled 1 = Enabled

Service Message Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> SERVICE Any valid ASCII string up to 128 characters

Threshold Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535

Resolution Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> 0 = Seconds 0 = Seconds 1 = Minutes

QX-870 Industrial Raster Scanner User Manual

A-77

Page 364

Serial Commands

Laser Current Warning Message High Current Status Serial Cmd: Default: Options:

<K411,high current status,high current message,low current status,low current message> 0 = Disabled 0 = Disabled 1 = Message

High Current Message Serial Cmd: Default: Options:

<K411,high current status,high current message,low current status,low current message> HIGH_LASER Any valid ASCII string up to 128 characters

Low Current Status Serial Cmd: Default: Options:

<K411,high current status,high current message,low current status,low current message> 0 = Disabled 0 = Disabled 1 = Message

Low Current Message Serial Cmd: Default: Options:

<K411,high current status,high current message,low current status,low current message> LOW_LASER Any valid ASCII string up to 128 characters

User-Defined Name Serial Cmd: Default: Options:

A-78

<K412,user-defined name> QX-870 Any valid ASCII string up to 50 characters

QX-870 Industrial Raster Scanner User Manual

Page 365

Appendices

Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Output Filter Enable

<K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology,length,wildcard,placeholder, data,decode direction,database index> <K745,number of filters>

Format Extract Output Index Serial Cmd:

<K740,output index,start location,length>

Options:

1 to 100

Start Location Serial Cmd:

<K740,output index,start location,length>

Default:

0

Options:

1 to n (maximum number of characters in the symbol data).

Length Serial Cmd:

<K740,output index,start location,length>

Default:

0 (Disabled; end of format cell array)

Options:

1 to n (maximum number of characters in the symbol data).

Format Insert Output Index Output Index refers to the database entry to be modified with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output. Starting with index # 1, enter either an extract or insert command to begin building the required output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until the string is complete. Serial Cmd: <K741,output index,length,hex string> Options:

1 to 100

QX-870 Industrial Raster Scanner User Manual

A-79

Page 366

Serial Commands Length Specifies the length of the user-defined character string that will be inserted. This function is limited to 4 characters per output index, so multiple indexes must be entered in order to insert longer character sequences. For example, to insert a 10-character sequence in user-defined output, three commands with consecutive index numbers would be required, where the first two character sequence lengths were 4 and the third was 2. Serial Cmd: <K741,output index,length,hex string> Default:

0 (Disabled; end of format cell array)

Options:

1 to 4

Hex String Specifies a character string that represents ASCII characters to be inserted in the database entry. Two hex characters are required for every ASCII character to be inserted in the user-defined output string. These two characters comprise the hex (base 16) value of the ASCII character. For example, to enter the three-character sequence “Hi!”, 3 would indicate the length of the string, and a hex sequence of 486921 would be the ASCII sequence to be inserted. (48 = H; 69 = i; 21 = !) Important: Each pair of hex characters represents one ASCII character. Hex character pairs range from 00 to FF. Since there is a limit of 4 ASCII characters per insertion per database entry, there is a limit of 8 hex characters per insertion per database entry. Serial Cmd: <K741,output index,length,hex string> Default:

NULL (0x00)

Options:

00 to FF (As many as 4 bytes, or hex pairs.)

Format Assign Symbol Number Serial Cmd: <K742,symbol number,status> Options:

1 to 10 1 = Formatted output status for symbol # 1. 2 = Formatted output status for symbol # 2. ... ... 10 = Formatted output status for symbol # 10.

Status Serial Cmd: <K742,symbol number,status> Default:

0 = Disabled

Options:

0 = Disabled 1 = Enabled (Assign parameters to specified symbol.)

A-80

QX-870 Industrial Raster Scanner User Manual

Page 367

Appendices

Output Format Status Serial Cmd: <K743,output format status> Default:

0 = Disabled

Options:

0 = Disabled 1 = Enabled

Output Filter Configuration Filter Number Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Options:

1 to 10

Symbology Type Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

0

Options:

0 = Any type 1 = Interleaved 2 of 5 2 = Code 39 3 = Code 128 4 = Codabar 5 = UPC 6 = PDF417 7 = EAN 128 8 = Code 93 9 = Pharmacode 10 = GS1 DataBar (RSS) 11 = MicroPDF417 12 = Composite

Length Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

0

Options:

0 to 128

Wildcard Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

* = (0x2A)

Options:

Any ASCII input in the form of a pair of hex characters

QX-870 Industrial Raster Scanner User Manual

A-81

Page 368

Serial Commands Placeholder Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

? = (0x3F)

Options:

Any ASCII input in the form of a pair of hex characters

Data Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

NULL (0x00)

Options:

Any ASCII input in the form of a pair of hex characters

Decode Direction Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

0 = Any Direction

Options:

0 = Any Direction 1 = Forward 2 = Reverse

Database Index Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:

0 (any index)

Options:

0 to 10

Output Filter Enable Serial Cmd: <K745,number of filters> Default:

0

Options:

0 to 10

A-82

QX-870 Industrial Raster Scanner User Manual

Page 369

Appendices

Serial Utility Commands Type

Read Rate

Counters

Device Control

Master Database

Part Number / Checksum

Command <C> <Cp> <J> <a1> <N> <O> <T> <U> <V> <W> <X> <Y> <L1> <L2> <L3> <I> <H> <G> <Gn> <NEWM> <#> <#a> <#b> <#f> <!> <!a> <!b> <!f> <Z> <Zc> <Zrc>

Default/Reset/Save

<Zrd> <Zrdall> <A> <Arp>

QX-870 Industrial Raster Scanner User Manual

Name Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests PDF417 Information No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display FPGA Code Part Number Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display FPGA Code Checksum Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On Recall Customer Default Settings and Save for Power-On Recall Microscan Default Settings and Save for Power-On (Will not default “sticky settings”) Recall Microscan Default Settings and Save for Power-On (Will also default “sticky settings”) Reset (Will not save for power-on) Reset and Recall Power-On Parameters

A-83

Page 370

Serial Commands Default/Reset/Save

Scanner Status Request Commands

Other Serial Utility Commands

A-84

<Arc> <Ard> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <@CAL> <@> <BCCFG>

Reset and Recall Customer Default Parameters Reset and Recall Microscan Default Parameters All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Default Customer Parameter Calibrate without Menu Calibrate with Menu Enter Bar Code Configuration

QX-870 Industrial Raster Scanner User Manual