Page 351

Appendices Control/Hex Output Serial Cmd: Default: Options:

<K701,serial command echo status,serial command beep status,control/hex output> 0 = Control 0 = Control 1 = Hex

Beeper Serial Cmd: Default: Options:

<K702,beeper status> 1 = Good Read 0 = Disabled 1 = Good Read

2 = No Read

Quality Output Separator Serial Cmd: Default: Options:

<K704,separator,decodes per trigger status> , (comma) Any 7-bit ASCII character

Decodes per Trigger Status Serial Cmd: Default: Options:

<K704,separator,decodes per trigger status> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Data Output Symbol Data Output Status Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 3 = Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

When to Output Symbol Data Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 0 = As Soon As Possible 0 = ASAP 1 = End of Read Cycle

Symbology ID Output Status Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 0 = Disabled 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID

QX-870 Industrial Raster Scanner User Manual

A-65

Page 352

Serial Commands

Read Duration Output Read Duration Output Mode Serial Cmd: Default: Options:

<K706,status,separator> 0 = Disabled 0 = Disabled 1 = Enabled

Read Duration Output Separator Serial Cmd: Default: Options:

<K706,status,separator> Space (0x20) Any 7-bit ASCII character

No Read Message No Read Message Status Serial Cmd: Default: Options:

<K714,No Read message status,No Read message> 1 = Enabled 0 = Disabled 1 = Enabled

No Read Message Serial Cmd: Default: Options:

<K714,no read message status,No Read message> NOREAD Any valid ASCII string up to 128 characters

Bad Symbol Message Bad Symbol Message Status Serial Cmd: Default: Options:

<K715,bad symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled

Bad Symbol Message Serial Cmd: Default: Options:

<K715,bad symbol message status,message> BAD_SYMBOL Any valid ASCII string up to 128 characters

No Symbol Message No Symbol Message Status Serial Cmd: Default: Options:

A-66

<K716,no symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

Page 353

Appendices No Symbol Message Serial Cmd: Default: Options:

<K716,no symbol message status,message> NO_SYMBOL Any valid ASCII string up to 128 characters

Input 1 Serial Cmd: Default: Options:

<K730,status,active state> 0 = Disabled 0 = Disabled 1 = Reset Counts 2 = Unlatch Output

Active State Serial Cmd: Default: Options:

<K730,status,active state> 0 = Active Open 0 = Active Open 1 = Active Closed

Green Flash LED Green Flash Mode Serial Cmd: Default: Options:

<K750,green flash mode,unused,green flash duration> 1 = Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe

Green Flash Duration Serial Cmd: Default: Options:

<K750,green flash mode,unused,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)

Status Indicators Serial Cmd: Default: Options:

<K751,status,bar graph,I/O 1,I/O 2> 1 = PHY Activity 0 = Disabled 1 = PHY Activity 2 = Protocol Activity

QX-870 Industrial Raster Scanner User Manual

A-67

Page 354

Serial Commands Bar Graph Serial Cmd: Default: Options:

<K751,status,bar graph,I/O 1,I/O 2> 1 = Read Rate / Good Read 0 = Disabled 1 = Read Rate / Good Read

I/O 1 Serial Cmd: Default: Options:

<K751,status,bar graph,I/O 1,I/O 2> 1 = Output Active 0 = Disabled 1 = Output Active 2 = Input Active

I/O 2 Serial Cmd: Default: Options:

<K751,status,bar graph,I/O 1,I/O 2> 2 = Input Active 0 = Disabled 1 = Output Active 2 = Input Active

Symbol Position Output Raster Position Output Status Serial Cmd: Default: Options:

<K758,raster position output status,scan position output status,separator> 0 = Disabled 0 = Disabled 1 = Enabled

Scan Position Output Status Serial Cmd: Default: Options:

<K758,raster position output status,scan position output status,separator> 0 = Disabled 0 = Disabled 1 = Enabled

Separator Serial Cmd: Default: Options:

A-68

<K758,raster position output status,scan position output status,separator> Space (0x20) Any 7-bit ASCII character

QX-870 Industrial Raster Scanner User Manual

Page 355

Appendices

Database Identifier Output Serial Cmd: Default: Options:

<K759,status,separator> 0 = Disabed 0 = Disabled 1 = Enabled

Separator Serial Cmd: Default: Options:

<K759,status,separator> Space (0x20) Any 7-bit ASCII character

EZ Button Global Status Serial Cmd: Default: Options:

<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch

Default on Power-On Serial Cmd: Default: Options:

<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled

EZ Button Modes Serial Cmd: Options:

<K771,single beep,two beeps,three beeps,four beeps> 0 = Disabled 1 = Enabled

Single Beep 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.

Two Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.

QX-870 Industrial Raster Scanner User Manual

Three Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.

Four Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.

A-69

Page 356

Serial Commands

Auto Framing Options Laser Status Serial Cmd: Default: Options:

<K773,unused,laser status> 1 = Enabled 0 = Disabled 1 = Enabled

Trend Analysis Output 1 Trend Analysis Mode Serial Cmd: Default: Options:

<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 1 = No Read 0 = Mismatch 1 = No Read 2 = Decodes per Trigger 3 = Bad Symbol 4 = No Symbol

Trigger Evaluation Period Serial Cmd: Default: Options:

<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255

Number to Output On Serial Cmd: Default: Options:

<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255

Decodes per Trigger Threshold Serial Cmd: Default: Options:

<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 65535

Trend Analysis Output 2 Serial Cmd:

<K781,trend analysis mode,trigger evaluation period,number to output on>

Trend Analysis Output 3 Serial Cmd:

A-70

<K782,trend analysis mode,trigger evaluation period,number to output on>

QX-870 Industrial Raster Scanner User Manual

Page 357

Appendices

Diagnostics Output 1 High Temperature Serial Cmd: Default: Options:

<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled

Service Unit Serial Cmd: Default: Options:

<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled

Laser Current High Serial Cmd: Default: Options:

<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled

Laser Current Low Serial Cmd: Default: Options:

<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled

Low Temperature Serial Cmd: Default: Options:

<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled

Diagnostics Output 2 Serial Cmd:

<K791,high temperature,service unit,unused,laser current high,laser current low,low temperature>

Diagnostics Output 3 Serial Cmd:

<K792,high temperature,service unit,unused,laser current high,laser current low,low temperature>

QX-870 Industrial Raster Scanner User Manual

A-71

Page 358

Serial Commands

Output 1 Parameters Output On Serial Cmd: Default: Options:

<K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = Validation 6 = Diagnostic Warning 7 = In Read Cycle 8 = Read Cycle Data Valid

Output State Serial Cmd: Default: Options:

<K810,output on,output state,pulse width,output mode> 0 = Normally Open 0 = Normally Open 1 = Normally Closed

Pulse Width Serial Cmd: Default: Options:

<K810,output on,output state,pulse width,output mode> 50 (50 ms) 1 to 65535 (in 1 ms increments)

Output Mode Serial Cmd: Default: Options:

<K810,output on,output state,pulse width,output mode> 0 = Pulse 0 = Pulse 1 = Latch Mode 1 (Unlatch Input 1 Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)

Output 2 Parameters Serial Cmd:

<K811,output on,output state,pulse width,output mode>

Configurable Output 3 Serial Cmd:

A-72

<K812,output on,output state,pulse width,output mode>

QX-870 Industrial Raster Scanner User Manual

Page 359

Appendices

Matchcode Matchcode Master Symbol Database Size New Master Pin Sequence Step Master Symbol Match Replace Mismatch Replace

<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K228,sequence step> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string>

Matchcode Matchcode Type Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Wild Card 3 = Sequential

Sequential Matching Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Increment 0 = Increment 1 = Decrement

Match Start Position Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 0 to 3000

Match Length Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 1 to 3000

QX-870 Industrial Raster Scanner User Manual

A-73

Page 360

Serial Commands Wild Card Character Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> * (asterisk) Any 7-bit ASCII character

Sequence on No Read Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 = Enabled 0 = Disabled 1 = Enabled

Sequence on Mismatch Serial Cmd: Default: Options:

<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled

Master Symbol Database Size Serial Cmd: Default: Options:

<K224,number of master symbols> 1 1 to 10

New Master Pin Serial Cmd: Default: Options:

<K225,status> 0 = Disabled 0 = Disabled

1 = Enabled

Sequence Step Serial Cmd: Default: Options:

<K228,sequence step> 1 1 to 32768

Master Symbol Index Serial Cmd: Options:

<K231,index,master symbol data> 1 to 32768

Master Symbol Data Serial Cmd: Options:

A-74

<K231,index,master symbol data> Any valid ASCII string

QX-870 Industrial Raster Scanner User Manual