For the Microscan QX-870

Page 131

Scanner Parameters

Laser Setup Laser Setup allows the user to configure Laser On/Off, Laser Framing Status, Laser On Position, Laser Off Position, and Laser Power.

Laser On/Off When Enabled, the laser is On only during the read cycle. When Disabled, the laser operates continuously. Note: A serial trigger or external trigger must be enabled for Laser On/Off to take effect.

Laser Framing Status When Enabled, the laser will be off for the duration of the Laser Off time (beginning from the start of the read cycle), and the laser will then be on for the duration of the Laser On time.

Laser On Position The duration of Laser Off time. Laser On Position is a ratio of the total scan width, with increments equal to 1/100th of the total scan width.

QX-870 Industrial Raster Scanner User Manual

5-65

Page 132

Read Cycle

Laser Off Position The duration of Laser On time. Laser Off Position is a ratio of the total scan width, with increments equal to 1/100th of the total scan width.

Laser Power Allows the user to select the Laser Power setting as follows: Low: Laser Power = ~0.6mW. Typically only needed for decoding high density symbols located close to the scanner. Medium: Laser Power = ~1.0mW. High: Laser Power = ~1.5mW. Typically used for decoding lower density symbols located far from the scanner.

5-66

QX-870 Industrial Raster Scanner User Manual

Page 133

Scanner Parameters

Raster Setup Raster Setup allows the user to configure Top Offset, Bottom Offset, Sweep Rate, and Read Cycle On/Off.

Top Offset A value of 0 = the side opposite the scanner connectors (the top of the scanner). A value of 255 = the side with the connectors (the bottom of the scanner). If Top Offset is greater than Bottom Offset, then Top defines the raster position in a straight line only. If Top is less than Bottom, then the raster will sweep back and forth between the Top and Bottom offsets if the sweep rate is greater than 0. The Top Offset is considered the “home” position.

Bottom Offset A value of 0 = the side opposite the scanner connectors (the top of the scanner). A value of 255 = the side with the connectors (the bottom of the scanner). If Top Offset is greater than Bottom Offset, then Top defines the raster position in a straight line only. If Top is less than Bottom, then the raster will sweep back and forth between the Top and Bottom offsets if the sweep rate is greater than 0.

QX-870 Industrial Raster Scanner User Manual

5-67

Page 134

Read Cycle

Sweep Rate Sweep rate defines how many times per second the raster passes between the Top Offset and Bottom Ooffset. For example, if sweep rate is set to 3, and the raster is starting at the Top Offset, it will reach the bottom offset in 1/3 of a second.

Read Cycle On/Off Always start a read cycle with the raster at the Top Offset, then enable the Read Cycle On/Off parameter. Note: The sweep rate must be significantly faster than the triggering rate in order for this feature to be effective.

5-68

QX-870 Industrial Raster Scanner User Manual

Page 135

Scanner Parameters

Symbologies Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Symbologies tab to display the Symbologies tree control.

To open nested options, single-click the +.

The * indicates that the setting is the default. To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Symbologies settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Symbologies section of Appendix E. QX-870 Industrial Raster Scanner User Manual

5-69

Page 136

Symbologies

Code 39 Code 39 is considered the standard for non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide.

Check Character Status Enables or Disables the check character.

Check Character Output Status Check Character Output Status, when added to the symbol, provides additional data security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character.

Note: With Check Character Output Status enabled and an External Edge, External Level, or Serial Data trigger option enabled, an invalid check character calculation will cause a No Read Message to be transmitted at the end of the read cycle.

Large Intercharacter Gap Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. When enabled, the scanner can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.

Important: Do not use Large Intercharacter Gap with Narrow or Narrow, Enhanced Quiet Zone enabled, because a large intercharacter gap (over 3x) could cause a narrow quiet zone (5x) to be interpreted as an intercharacter gap. 5-70

QX-870 Industrial Raster Scanner User Manual

Page 137

Scanner Parameters

Fixed Symbol Length Status When enabled, the scanner will check the symbol length against the symbol length field. If disabled, any length will be considered valid.

Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check character characters). The scanner ignores any symbology that does not match the specified length.

Full ASCII Set Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the scanner can read the full ASCII character set, from 0 to 255.

QX-870 Industrial Raster Scanner User Manual

5-71

Page 138

Symbologies

Code 128 Code 128 is a smaller symbology useful in applications with limited space and high-security requirements. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.

Fixed Symbol Length Status When enabled, the scanner will check the symbol length against the symbol length field. If disabled, any length will be considered a valid symbol.

Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the scanner will recognize (this does not include start, stop, and check character characters). The scanner ignores any symbol not having the specified length.

5-72

QX-870 Industrial Raster Scanner User Manual

Page 139

Scanner Parameters

EAN Status When this field is disabled, the scanner will not check any Code 128 labels for conformance to EAN requirements, or perform any special formatting. When enabled, the scanner can read symbols with or without a function 1 character in the first position. If a symbol has a function 1 character in the first position, it must conform to EAN format. Symbols that conform to EAN format will also be subject to the special output formatting options available in this command. If EAN status is required, the scanner will only decode symbols that have a function 1 character in the first position and that conform to EAN format. All symbols read will be subject to the special output formatting options available in this command.

Note: Code 128 status must be enabled for EAN status to be active.

Output Format In Standard, the scanner will not apply special EAN output formatting options. In Application, the scanner will apply the special EAN output formatting options to decoded EAN-conforming symbols.

QX-870 Industrial Raster Scanner User Manual

5-73

Page 140

Symbologies

Application Record Separator Status When enabled, an EAN separator will be inserted into the output between fields whenever an EAN-conforming symbol is decoded and EAN output formatting applies.

Application Record Separator Character This is an ASCII character that serves as an EAN separator in formatted EAN output.

Application Record Brackets If an EAN-conforming symbol is decoded and EAN formatting applies, this feature places bracket characters around the application identifiers in the formatted output.

Application Record Padding This feature causes the scanner to pad variable-length application fields with leading zeroes. This is not done for the last field of a symbol.

5-74

QX-870 Industrial Raster Scanner User Manual