For the Microscan QX-870

Page 121

Scanner Parameters

Processing Timeout Useful in higher speed applications with long processing times.

Note: If a timeout occurs during processing and no symbols in the field of view have been decoded, the result will be a No Read. For this reason, a longer timeout should be tried to ensure that the symbol is decoded successfully.

QX-870 Industrial Raster Scanner User Manual

5-55

Page 122

Read Cycle

Reader Setup Reader Setup parameters allow the user to configure Gain Level, Tracking, and Scan Speed parameters, as well as various Automatic Gain Control parameters.

Gain Level Gain Level can be used in two different ways, depending on the AGC Sampling Mode. When AGC Sampling Mode is set to Disabled: Gain Level is used as a “Fixed Gain”. The analog signal is amplified by this gain value. For Fixed Gain operation, changes to gain adjustment setting should be performed in Auto Calibration. When AGC Sampling Mode is set to Leading Edge or Continuous: Gain Level defines the “set point” analog signal level. The AGC system will attempt to hold the analog signal at this level by automatically raising and lowering the gain as needed.

5-56

QX-870 Industrial Raster Scanner User Manual

Page 123

Scanner Parameters

Tracking Useful in fine-tuning tracking or when conditions of poor contrast or blurred bar edges exist. Tracks peak signals and selects an amplitude reference point to sample the analog signals for converting to digital. Note: Tracking is optimized at the factory before shipment; in some cases the default value might not be 40.

Scan Speed Allows the user to set the number of scans per second by controlling the motor speed of the spinning mirror in the scanner.

QX-870 Industrial Raster Scanner User Manual

5-57

Page 124

Read Cycle

Automatic Gain Control AGC Sampling Mode Disabled (Fixed Gain) When AGC Sampling Mode is Disabled, the first parameter in the Gain Level command defines the Fixed Gain used to amplify the analog signal. In most applications, when changing the sampling mode to Disabled, the Gain Level will need to be changed. For Fixed Gain operation, changes to gain adjustment settings can be performed in Auto Calibration. Leading Edge Leading Edge uses only the first signal sample to calculate gain adjustments. The Transition Counter value is used to determine which transition triggers the sample. Important: This option should only be used if recommended by a Microscan Sales or Applications representative, as the other AGC modes cover most application requirements. Continuous Continuous will take the highest value among any samples within a scan and use that value to make adjustments.

5-58

QX-870 Industrial Raster Scanner User Manual

Page 125

Scanner Parameters

AGC Minimum Sets a gain limit that AGC cannot go below when not in Fixed Gain operation.

AGC Maximum Sets a gain limit that AGC cannot exceed when not in Fixed Gain operation.

QX-870 Industrial Raster Scanner User Manual

5-59

Page 126

Read Cycle

Symbol Detect Status When Symbol Detect Status is enabled, Bad Symbol/No Symbol is output depending on whether or not there were enough transition counts, rather than based on a simple No Read. Note: Symbol detection can only be used when AGC Sampling Mode is set to Disabled (Fixed Gain).

Transition Counter Number of bar/space transitions required for an AGC sample. When multiple samples take place within a scan, the largest value is used. If symbol detection is enabled, the transition counter defines the minimum number of transitions required for a scan to qualify as a No Symbol (number of transitions < transition counter), or Bad Symbol (number of transitions > or = transition counter and no decode).

5-60

QX-870 Industrial Raster Scanner User Manual

Page 127

Scanner Parameters

Maximum Element Maximum Element is the maximum bar (element) size before a reset. Value is in increments of 0.01% of the scanner’s full scan width, not increments of the framed scan width.

Scan Width Enhance The scanner can adjust for Gain differences across the entire scan width. This is a useful feature for long symbols that use most of the scan width available. Note: This command is intended for applications in which symbols are three inches or more from the scanner.

Disabled The scanner will not adjust for scan width variation.

Enabled The scanner will adjust for scan width variation.

QX-870 Industrial Raster Scanner User Manual

5-61

Page 128

Read Cycle

Additional Information about Gain, Tracking, and Transition Counter Gain The QX-870 Industrial Raster Scanner is an optical device. Optical devices deal with a wide range of brightness, in a way similar to a camera. If the image is too bright, the exposure must be reduced. If the image is too dark, the exposure must be increased. The scanner will only work properly if it is within the range of brightness that can resolve light and dark changes, or “transitions”, in the field of view. If the gain is too low, the entire symbol looks like a dark bar to the scanner. If the gain is too high, the entire symbol looks like a white bar to the scanner. Brightness conditions can be affected by the distance between the symbol and scanner, or by the consistency of the material on which the symbol is printed. The AGC Sampling Mode command has two primary functions: AGC (either Leading Edge or Continuous) and Disabled (Fixed Gain). AGC (Leading Edge or Continuous) AGC self-adjusts the optical-electrical gain to hold brightness to one range for all materials and distances. The Auto Calibration menu shows what AGC is doing to control brightness, as in the example shown here:

The value –35.0 indicates that brightness has been reduced by 35 dB. The symbol used in this example was very close to the scanner, using high laser power. As the laser power is lowered and/or the symbol is moved farther from the scanner, the attenuation (brightness reduction) value becomes lower. The user does nothing to adjust the gain in order to keep the scanner decoding; AGC performs the task of raising gain to accommodate the greater distance. The actual attenuation factor is determined by the return light from the symbol and the “SETPOINT” value that the control system is attempting to hold. (SETPOINT is an abstracted number range that has to do with the feedback system’s dynamic range.) A very low SETPOINT value of 0-20 would tend to keep the symbol amplitude low. A very high SETPOINT value of 150-255 would tend to keep the symbol amplitude high. The gain will change to hold the feedback value equal to the user SETPOINT setting of amplitude (Gain Level) at all times. Disabled (Fixed Gain) Fixed Gain is a gain mode in which there are no changes in the gain system. The system takes the total gain range and divides it into 255 steps. Then the value of the Gain Level setting is converted directly into the gain value. Nothing will change this value unless the user changes the Gain Level setting.

5-62

QX-870 Industrial Raster Scanner User Manual

Page 129

Scanner Parameters When To Use Fixed Gain vs. AGC The AGC settings (Leading Edge or Continuous) are preferable for most applications, as they provide the best overall scannable area. However, there are times when AGC will have difficulty locking onto the symbol of interest, especially when extraneous non-symbol objects in the field of view appear to be symbols. AGC can only base its measurements on one object. If that object is not the actual symbol, AGC performance and consistency are adversely affected. Leading Edge bases its calculations on the first object it detects, even if the first object is not a symbol. This is helpful if the symbol is always at the leading edge of the decode direction. Continuous is the recommended setting for Microscan scanners. Continuous always samples throughout the entire scan but is most interested in the object with the most sharply-defined bars. This can occasionally mislead the scanner when bar-like objects or specular reflection enter the field of view. Fixed Gain is preferable if AGC repeatedly fails to choose the correct Gain Level setting for the application. In some applications, symbols might be surrounded by a greater number of symbol-like false candidates than actual symbols. The Fixed Gain setting will never change its value, so once it is set, surrounding objects in the field of view will not distract the scanner from decoding actual symbols. Fixed Gain is also useful in applications using symbols that have very low bar counts, or in applications using Symbol Reconstruction on symbols with tilted or skewed placement. The AGC Minimum and AGC Maximum parameters are useful in applications with depth of field limitations that are not conducive to Fixed Gain operation. To determine the appropriate minimum and maximum gain: • Set AGC Sampling Mode to Disabled (Fixed Gain) and find the range of gain levels that yields successful decodes in the application (both the lowest and the highest gain levels). • Enter those values in the AGC Minimum and AGC Maximum fields. This will leave the scanner room for gain changes to increase depth of field (within the limitations of what works for the application). Maximum gain may be too high for symbols on white backgrounds, because it may attempt to process false bars. Especially in applications using symbologies that require more processing, setting gain too high can slow decode performance substantially. Setting a minimum gain can prevent the system from occasionally “under-gaining” because of previous false candidates that appear very bright.

QX-870 Industrial Raster Scanner User Manual

5-63

Page 130

Read Cycle

Tracking Tracking is the frequency detection value that determines the threshold between a white bar and a black bar. This is a range of frequencies that have been divided into 127 steps. For most applications, the default tracking value (40) is robust enough to deal with most marginal signals. However, in some instances, symbols are printed on a “noisy” substrate, or symbols are relatively distant from the scanner and the signal-to-noise ratio and optical focus are not ideal. In such cases, using a combination of Gain Level and Tracking can improve decode performance by rejecting “noise” and correctly recognizing the bars of the candidate symbol.

Transition Counter Transition Counter is an integral part of the AGC system. Transition Counter determines the number of black bars that will be counted before an AGC sample is taken. Setting a Transition Counter value lower than the default of 14 gives the scanner less integration time for the candidate symbol, and makes the scanner more susceptible to false objects. A Transition Counter value greater than 14 requires more bars to be present for the symbol even to qualify as an object. When setting the Transition Counter value, it is important to keep in mind what occurs when the symbol is first presented to the scanner - before gain is applied to the symbol. A few bars are usually missed due to distortion at first. Setting Transition Counter to the same value as the number of bars contained in the symbol can cause the scanner not to take an AGC sample at all. The value of 14 is optimal except in the case of low bar count due to: • Symbols that are tilted so that only 10 bars or fewer are available in a single scan line. (See Symbol Reconstruction). • Symbologies with typically low bar counts, such as Pharmacode. Applications using symbols with fewer than 10 bars should use Fixed Gain operation.

5-64

QX-870 Industrial Raster Scanner User Manual