The text of a manual · part 36 of 43
QX-830 Compact Industrial Scanner User Manual, pages 351 to 360
Pages 351 to 360 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 351
Appendices I/O 1 Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 1 = Output Active 0 = Disabled 1 = Output Active 2 = Input Active
I/O 2 Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 2 = Input Active 0 = Disabled 1 = Output Active 2 = Input Active
Symbol Position Output Scan Status Serial Cmd: Default: Options:
<K758,scan status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
Separator Serial Cmd: Default: Options:
<K758,scan status,separator> Space (0x20) Any 7-bit ASCII character
Database Identifier Output Serial Cmd: Default: Options:
<K759,status,separator> 0 = Disabed 0 = Disabled 1 = Enabled
Separator Serial Cmd: Default: Options:
<K759,status,separator> Space (0x20) Any 7-bit ASCII character
QX-830 Compact Industrial Scanner User Manual
A-63
Page 352
Serial Commands
EZ Button Global Status Serial Cmd: Default: Options:
<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch
Default on Power-On Serial Cmd: Default: Options:
<K770,global status,default on power-on> 1 = Enabled 0 = Disabled 1 = Enabled
EZ Button Modes Serial Cmd: Options:
<K771,single beep,two beeps,three beeps,four beeps> 0 = Disabled 1 = Enabled
Single Beep 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Auto Calibration 3 = Save for Power-On 4 = Auto Framing 5 = Load New Master 6 = Sleep Mode 7 = Unused 8 = Unused 9 = Bar Code Config.
Auto Framing Options Laser Status Serial Cmd: Default: Options:
A-64
<K773,unused,laser status> 1 = Enabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
Page 353
Appendices
Trend Analysis Output 1 Trend Analysis Mode Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 1 = No Read 0 = Mismatch 1 = No Read 2 = Decodes per Trigger 3 = Bad Symbol 4 = No Symbol
Trigger Evaluation Period Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Number to Output On Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 255
Decodes per Trigger Threshold Serial Cmd: Default: Options:
<K780,trend analysis mode,trigger evaluation period,number to output on, decodes per trigger threshold> 0 0 to 65535
Trend Analysis Output 2 Serial Cmd:
<K781,trend analysis mode,trigger evaluation period,number to output on>
Trend Analysis Output 3 Serial Cmd:
<K782,trend analysis mode,trigger evaluation period,number to output on>
Diagnostics Output 1 High Temperature Serial Cmd: Default: Options:
<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
A-65
Page 354
Serial Commands Service Unit Serial Cmd: Default: Options:
<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled
Laser Current High Serial Cmd: Default: Options:
<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled
Laser Current Low Serial Cmd: Default: Options:
<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled
Low Temperature Serial Cmd: Default: Options:
<K790,high temperature,service unit,unused,laser current high,laser current low,low temperature> 0 = Disabled 0 = Disabled 1 = Enabled
Diagnostics Output 2 Serial Cmd:
<K791,high temperature,service unit,unused,laser current high,laser current low,low temperature>
Diagnostics Output 3 Serial Cmd:
A-66
<K792,high temperature,service unit,unused,laser current high,laser current low,low temperature>
QX-830 Compact Industrial Scanner User Manual
Page 355
Appendices
Output 1 Parameters Output On Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = unused 6 = Diagnostic Warning 7 = In Read Cycle
Output State Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Normally Open 0 = Normally Open 1 = Normally Closed
Pulse Width Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 50 (50 ms) 1 to 65535 (in 1 ms increments)
Output Mode Serial Cmd: Default: Options:
<K810,output on,output state,pulse width,output mode> 0 = Pulse 0 = Pulse 1 = Latch Mode 1 (Unlatch Input 1 Pin) 2 = Latch Mode 2 (Unlatch Opposite Condition) 3 = Latch Mode 3 (Unlatch Re-Enter Read Cycle)
Output 2 Parameters Serial Cmd:
<K811,output on,output state,pulse width,output mode>
Configurable Output 3 Serial Cmd:
<K812,output on,output state,pulse width,output mode>
QX-830 Compact Industrial Scanner User Manual
A-67
Page 356
Serial Commands
Matchcode Matchcode Master Symbol Database Size New Master Pin Sequence Step Master Symbol Match Replace Mismatch Replace
<K223,matchcode type,sequential matching,match start position, match length,wild card,sequence on no read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K228,sequence step> <K231,index,master symbol data> <K735,status,replacement string> <K736,status,replacement string>
Matchcode Matchcode Type Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Wild Card 3 = Sequential
Sequential Matching Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Increment 0 = Increment 1 = Decrement
Match Start Position Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> 0 0 to 3000
Match Length Serial Cmd: Default: Options:
A-68
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 1 to 3000
QX-830 Compact Industrial Scanner User Manual
Page 357
Appendices Wild Card Character Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> * (asterisk) Any 7-bit ASCII character
Sequence on No Read Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 = Enabled 0 = Disabled 1 = Enabled
Sequence on Mismatch Serial Cmd: Default: Options:
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 0 = Disabled 0 = Disabled 1 = Enabled
Master Symbol Database Size Serial Cmd: Default: Options:
<K224,number of master symbols> 1 1 to 10
New Master Pin Serial Cmd: Default: Options:
<K225,status> 0 = Disabled 0 = Disabled
1 = Enabled
Sequence Step Serial Cmd: Default: Options:
<K228,sequence step> 1 1 to 32768
Master Symbol Index Serial Cmd: Options:
<K231,index,master symbol data> 1 to 32768
Master Symbol Data Serial Cmd: Options:
<K231,index,master symbol data> Any valid ASCII string
QX-830 Compact Industrial Scanner User Manual
A-69
Page 358
Serial Commands
Match Replace Serial Cmd: Default: Options:
<K735,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled
Replacement String Serial Cmd: Default: Options:
<K735,status,replacement string> MATCH Any valid ASCII string up to 128 characters
Mismatch Replace Serial Cmd: Default: Options:
<K736,status,replacement string> 0 = Disabled 0 = Disabled 1 = Enabled
Replacement String Serial Cmd: Default: Options:
A-70
<K736,status,replacement string> MISMATCH Any valid ASCII string up to 128 characters
QX-830 Compact Industrial Scanner User Manual
Page 359
Appendices
Diagnostics High Temperature Threshold Low Temperature Threshold Counts (Read-only) Hours Since Reset (Read-only) Service Message Laser Current Warning Message User-Defined Name
<K402,status,message> <K403,status,message> <K406> (returns: power-on,resets, power-on saves,custom default saves) <K407> (returns: hours,minutes) <K409,status,service message, threshold,resolution> <K411,laser high status,laser high message,laser low status, laser low message> <K412,user-defined name>
High Temperature Threshold Serial Cmd: Default: Options:
<K402,status,message> 0 = Disabled 0 = Disabled
1 = Enabled
Message Serial Cmd: Default: Options:
<K402,status,message> HIGH_TEMP Any valid ASCII string up to 128 characters
Low Temperature Threshold Serial Cmd: Default: Options:
<K403,status,message> 0 = Disabled 0 = Disabled
1 = Enabled
Message Serial Cmd: Default: Options:
<K403,status,message> LOW_TEMP Any valid ASCII string up to 128 characters
Counts (Read-only) Power-On Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments on scanner power-on.
Resets Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments on scanner reset. Value is reset on power-on.
QX-830 Compact Industrial Scanner User Manual
A-71
Page 360
Serial Commands Power-On Saves Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments when a scanner setting is saved for power-on (<Z> command).
Custom Default Saves Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves> 16-bit counter that increments when a scanner setting is saved to the customer parameter section of flash memory (<Zc> command).
Hours Since Reset (Read-only) Hours Serial Cmd:
<K407,hours,minutes> 16-bit counter (0 to 65535)
Minutes Serial Cmd:
<K407,hours,minutes> 16-bit counter (0 to 60)
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 0 = Disabled 0 = Disabled 1 = Enabled
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> SERVICE Any valid ASCII string up to 128 characters
Threshold Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535
Resolution Serial Cmd: Default: Options:
A-72
<K409,status,service message,threshold,resolution> 0 = Seconds 0 = Seconds 1 = Minutes
QX-830 Compact Industrial Scanner User Manual