Page 341

Appendices Separation Factor Serial Cmd:

Default: Options:

<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest

Code 93 Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge

Fixed Symbol Length Status (Code 93) Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length (Code 93) Serial Cmd: Default: Options:

<K475,status,fixed symbol length status,symbol length> 10 1 to 128

PDF417 Serial Cmd: Default: Options:

<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Scan Line Limit Serial Cmd: Default: Options:

<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 65535 (Disabled) 1 to 65535

QX-830 Compact Industrial Scanner User Manual

A-53

Page 342

Serial Commands Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:

<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (PDF417) Serial Cmd: Default: Options:

<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 10 1 to 2710

Decode at End of Read Cycle (PDF417) Serial Cmd: Default: Options:

<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled

Pharmacode Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (Pharmacode) Serial Cmd: Default: Options:

A-54

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 10 1 to 16

QX-830 Compact Industrial Scanner User Manual

Page 343

Appendices Minimum Bars (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 4 1 to 16

Bar Width Status (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold

Direction (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Forward 0 = Forward 1 = Reverse

Fixed Threshold Value (Pharmacode) Serial Cmd: Default: Options:

<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 400 1 to 65535

GS1 DataBar (RSS) DataBar Omnidirectional (RSS-14) Serial Cmd: Default: Options:

<K482,status> 0 = Disabled 0 = Disabled

1 = Enabled

DataBar Limited (RSS Limited) Serial Cmd: Default: Options:

<K483,status> 0 = Disabled 0 = Disabled

1 = Enabled

DataBar Expanded (RSS Expanded) Serial Cmd: Default: Options:

<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

QX-830 Compact Industrial Scanner User Manual

A-55

Page 344

Serial Commands Fixed Symbol Length Status (DataBar Expanded) Serial Cmd: Default: Options:

<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (DataBar Expanded) Serial Cmd: Default: Options:

<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74

MicroPDF417 Serial Cmd: Default: Options:

<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Scan Line Limit (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 200 1 to 65535

Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (MicroPDF417) Serial Cmd: Default: Options:

A-56

<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 10 1 to 366

QX-830 Compact Industrial Scanner User Manual

Page 345

Appendices

Symbol Reconstruction Symbol Reconstruction Redundancy Serial Cmd: Default: Options:

<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Disabled 0 = Disabled 1 = Low 2 = Medium 3 = High

Symbol Reconstruction Effort Serial Cmd: Default: Options:

<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Minimum 0 = Minimum 1 = Moderate 2 = Maximum

QX-830 Compact Industrial Scanner User Manual

A-57

Page 346

Serial Commands

I/O Parameters Calibration Options Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output No Read Message Bad Symbol Message No Symbol Message Input 1 Green Flash LED Status Indicators Symbol Position Output Database Identifier Output EZ Button EZ Button Modes Auto Framing Options Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3 Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters

<K521,unused,video,scan speed,laser power,laser framing, symbology> <K701,serial command echo status, serial command beep status, control/hex output> <K702,status> <K704,quality output separator, decodes per trigger status, decode direction output> <K705,symbol data output status, when to output symbol data, symbology i.d. output status> <K706,status,separator> <K714,status,message> <K715,status,message> <K716,status,message> <K730,input mode,active state> <K750,green flash mode,unused,green flash duration> <K751,status,bar graph,I/O 1,I/O 2> <K758,scan status,separator> <K759,status,separator character> <K770,status,default on power-on> <K771,single beep,two beeps,three beeps,four beeps> <K773,laser framing> <K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K790,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K791,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K792,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode>

Calibration Options Video Serial Cmd: Default: Options:

A-58

<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate

QX-830 Compact Industrial Scanner User Manual

Page 347

Appendices Scan Speed Serial Cmd: Default: Options:

<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate

Laser Power Serial Cmd: Default: Options:

<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate

Laser Framing Serial Cmd: Default: Options:

<K521,unused,video,scan speed,laser power,laser framing,symbology> 0 = Don’t Calibrate 0 = Don’t Calibrate 1 = Calibrate

Symbology Serial Cmd: Default: Options:

<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate

Serial Verification Serial Command Echo Status Serial Cmd: Default: Options:

<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled

Serial Command Beep Status Serial Cmd: Default: Options:

<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled

Control/Hex Output Serial Cmd: Default: Options:

<K701,serial command echo status,serial command beep status,control/hex output> 0 = Control 0 = Control 1 = Hex

QX-830 Compact Industrial Scanner User Manual

A-59

Page 348

Serial Commands

Beeper Serial Cmd: Default: Options:

<K702,beeper status> 1 = Good Read 0 = Disabled 1 = Good Read

2 = No Read

Quality Output Separator Serial Cmd: Default: Options:

<K704,separator,decodes per trigger status> , (comma) Any 7-bit ASCII character

Decodes per Trigger Status Serial Cmd: Default: Options:

<K704,separator,decodes per trigger status> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Data Output Symbol Data Output Status Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 3 = Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

When to Output Symbol Data Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 0 = As Soon As Possible 0 = ASAP 1 = End of Read Cycle

Symbology ID Output Status Serial Cmd: Default: Options:

<K705,symbol data output status,when to output,symbology i.d. output status> 0 = Disabled 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID

Read Duration Output Read Duration Output Mode Serial Cmd: Default: Options: A-60

<K706,status,separator> 0 = Disabled 0 = Disabled 1 = Enabled QX-830 Compact Industrial Scanner User Manual

Page 349

Appendices Read Duration Output Separator Serial Cmd: Default: Options:

<K706,status,separator> Space (0x20) Any 7-bit ASCII character

No Read Message No Read Message Status Serial Cmd: Default: Options:

<K714,No Read message status,No Read message> 1 = Enabled 0 = Disabled 1 = Enabled

No Read Message Serial Cmd: Default: Options:

<K714,no read message status,No Read message> NOREAD Any valid ASCII string up to 128 characters

Bad Symbol Message Bad Symbol Message Status Serial Cmd: Default: Options:

<K715,bad symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled

Bad Symbol Message Serial Cmd: Default: Options:

<K715,bad symbol message status,message> BAD_SYMBOL Any valid ASCII string up to 128 characters

No Symbol Message No Symbol Message Status Serial Cmd: Default: Options:

<K716,no symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled

No Symbol Message Serial Cmd: Default: Options:

<K716,no symbol message status,message> NO_SYMBOL Any valid ASCII string up to 128 characters

QX-830 Compact Industrial Scanner User Manual

A-61

Page 350

Serial Commands

Input 1 Serial Cmd: Default: Options:

<K730,status,active state> 0 = Disabled 0 = Disabled 1 = Reset Counts 2 = Unlatch Output

Active State Serial Cmd: Default: Options:

<K730,status,active state> 0 = Active Open 0 = Active Open 1 = Active Closed

Green Flash LED Green Flash Mode Serial Cmd: Default: Options:

<K750,green flash mode,unused,green flash duration> 1 = Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe

Green Flash Duration Serial Cmd: Default: Options:

<K750,green flash mode,unused,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)

Status Indicators Serial Cmd: Default: Options:

<K751,status,bar graph,I/O 1,I/O 2> 1 = PHY Activity 0 = Disabled 1 = PHY Activity 2 = Protocol Activity

Bar Graph Serial Cmd: Default: Options:

A-62

<K751,status,bar graph,I/O 1,I/O 2> 1 = Read Rate / Good Read 0 = Disabled 1 = Read Rate / Good Read

QX-830 Compact Industrial Scanner User Manual