Page 341
Appendices Separation Factor Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Normal 0 = Normal 1 = High 2 = Highest
Code 93 Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 93) Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Code 93) Serial Cmd: Default: Options:
<K475,status,fixed symbol length status,symbol length> 10 1 to 128
PDF417 Serial Cmd: Default: Options:
<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Scan Line Limit Serial Cmd: Default: Options:
<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 65535 (Disabled) 1 to 65535
QX-830 Compact Industrial Scanner User Manual
A-53
Page 342
Serial Commands Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:
<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (PDF417) Serial Cmd: Default: Options:
<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 10 1 to 2710
Decode at End of Read Cycle (PDF417) Serial Cmd: Default: Options:
<K476,status,scan line limit,fixed symbol length status,fixed symbol length,unused,decode at end of read cycle> 0 = Disabled 0 = Disabled 1 = Enabled
Pharmacode Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Serial Cmd: Default: Options:
A-54
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 10 1 to 16
QX-830 Compact Industrial Scanner User Manual
Page 343
Appendices Minimum Bars (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 4 1 to 16
Bar Width Status (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 0 = Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Serial Cmd: Default: Options:
<K477,status,fixed symbol length status,fixed symbol length,minimum bars,bar width status,direction,fixed threshold value> 400 1 to 65535
GS1 DataBar (RSS) DataBar Omnidirectional (RSS-14) Serial Cmd: Default: Options:
<K482,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Limited (RSS Limited) Serial Cmd: Default: Options:
<K483,status> 0 = Disabled 0 = Disabled
1 = Enabled
DataBar Expanded (RSS Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
A-55
Page 344
Serial Commands Fixed Symbol Length Status (DataBar Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (DataBar Expanded) Serial Cmd: Default: Options:
<K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74
MicroPDF417 Serial Cmd: Default: Options:
<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Scan Line Limit (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 200 1 to 65535
Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (MicroPDF417) Serial Cmd: Default: Options:
A-56
<K485,status,scan line limit,fixed symbol length status,fixed symbol length> 10 1 to 366
QX-830 Compact Industrial Scanner User Manual
Page 345
Appendices
Symbol Reconstruction Symbol Reconstruction Redundancy Serial Cmd: Default: Options:
<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Disabled 0 = Disabled 1 = Low 2 = Medium 3 = High
Symbol Reconstruction Effort Serial Cmd: Default: Options:
<K496,symbol reconstruction redundancy,symbol reconstruction effort> 0 = Minimum 0 = Minimum 1 = Moderate 2 = Maximum
QX-830 Compact Industrial Scanner User Manual
A-57
Page 346
Serial Commands
I/O Parameters Calibration Options Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output No Read Message Bad Symbol Message No Symbol Message Input 1 Green Flash LED Status Indicators Symbol Position Output Database Identifier Output EZ Button EZ Button Modes Auto Framing Options Trend Analysis Output 1 Trend Analysis Output 2 Trend Analysis Output 3 Diagnostics Output 1 Diagnostics Output 2 Diagnostics Output 3 Output 1 Parameters Output 2 Parameters Output 3 Parameters
<K521,unused,video,scan speed,laser power,laser framing, symbology> <K701,serial command echo status, serial command beep status, control/hex output> <K702,status> <K704,quality output separator, decodes per trigger status, decode direction output> <K705,symbol data output status, when to output symbol data, symbology i.d. output status> <K706,status,separator> <K714,status,message> <K715,status,message> <K716,status,message> <K730,input mode,active state> <K750,green flash mode,unused,green flash duration> <K751,status,bar graph,I/O 1,I/O 2> <K758,scan status,separator> <K759,status,separator character> <K770,status,default on power-on> <K771,single beep,two beeps,three beeps,four beeps> <K773,laser framing> <K780,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K781,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K782,trend analysis mode,number of triggers,number to output on,decodes per trigger> <K790,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K791,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K792,high temperature,service unit,unused,laser current high, laser current low,low temperature> <K810,output on,output state,pulse width,output mode> <K811,output on,output state,pulse width,output mode> <K812,output on,output state,pulse width,output mode>
Calibration Options Video Serial Cmd: Default: Options:
A-58
<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate
QX-830 Compact Industrial Scanner User Manual
Page 347
Appendices Scan Speed Serial Cmd: Default: Options:
<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate
Laser Power Serial Cmd: Default: Options:
<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate
Laser Framing Serial Cmd: Default: Options:
<K521,unused,video,scan speed,laser power,laser framing,symbology> 0 = Don’t Calibrate 0 = Don’t Calibrate 1 = Calibrate
Symbology Serial Cmd: Default: Options:
<K521,unused,video,scan speed,laser power,laser framing,symbology> 1 = Calibrate 0 = Don’t Calibrate 1 = Calibrate
Serial Verification Serial Command Echo Status Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status, control/hex output> 0 = Disabled 0 = Disabled 1 = Enabled
Control/Hex Output Serial Cmd: Default: Options:
<K701,serial command echo status,serial command beep status,control/hex output> 0 = Control 0 = Control 1 = Hex
QX-830 Compact Industrial Scanner User Manual
A-59
Page 348
Serial Commands
Beeper Serial Cmd: Default: Options:
<K702,beeper status> 1 = Good Read 0 = Disabled 1 = Good Read
2 = No Read
Quality Output Separator Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> , (comma) Any 7-bit ASCII character
Decodes per Trigger Status Serial Cmd: Default: Options:
<K704,separator,decodes per trigger status> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Data Output Symbol Data Output Status Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 3 = Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read
When to Output Symbol Data Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 0 = As Soon As Possible 0 = ASAP 1 = End of Read Cycle
Symbology ID Output Status Serial Cmd: Default: Options:
<K705,symbol data output status,when to output,symbology i.d. output status> 0 = Disabled 0 = Disabled 1 = Enabled (AIM-Defined ID) 2 = Readable ID
Read Duration Output Read Duration Output Mode Serial Cmd: Default: Options: A-60
<K706,status,separator> 0 = Disabled 0 = Disabled 1 = Enabled QX-830 Compact Industrial Scanner User Manual
Page 349
Appendices Read Duration Output Separator Serial Cmd: Default: Options:
<K706,status,separator> Space (0x20) Any 7-bit ASCII character
No Read Message No Read Message Status Serial Cmd: Default: Options:
<K714,No Read message status,No Read message> 1 = Enabled 0 = Disabled 1 = Enabled
No Read Message Serial Cmd: Default: Options:
<K714,no read message status,No Read message> NOREAD Any valid ASCII string up to 128 characters
Bad Symbol Message Bad Symbol Message Status Serial Cmd: Default: Options:
<K715,bad symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled
Bad Symbol Message Serial Cmd: Default: Options:
<K715,bad symbol message status,message> BAD_SYMBOL Any valid ASCII string up to 128 characters
No Symbol Message No Symbol Message Status Serial Cmd: Default: Options:
<K716,no symbol message status,message> 0 = Disabled 0 = Disabled 1 = Enabled
No Symbol Message Serial Cmd: Default: Options:
<K716,no symbol message status,message> NO_SYMBOL Any valid ASCII string up to 128 characters
QX-830 Compact Industrial Scanner User Manual
A-61
Page 350
Serial Commands
Input 1 Serial Cmd: Default: Options:
<K730,status,active state> 0 = Disabled 0 = Disabled 1 = Reset Counts 2 = Unlatch Output
Active State Serial Cmd: Default: Options:
<K730,status,active state> 0 = Active Open 0 = Active Open 1 = Active Closed
Green Flash LED Green Flash Mode Serial Cmd: Default: Options:
<K750,green flash mode,unused,green flash duration> 1 = Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe
Green Flash Duration Serial Cmd: Default: Options:
<K750,green flash mode,unused,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)
Status Indicators Serial Cmd: Default: Options:
<K751,status,bar graph,I/O 1,I/O 2> 1 = PHY Activity 0 = Disabled 1 = PHY Activity 2 = Protocol Activity
Bar Graph Serial Cmd: Default: Options:
A-62
<K751,status,bar graph,I/O 1,I/O 2> 1 = Read Rate / Good Read 0 = Disabled 1 = Read Rate / Good Read
QX-830 Compact Industrial Scanner User Manual