The text of a manual · part 34 of 43
QX-830 Compact Industrial Scanner User Manual, pages 331 to 340
Pages 331 to 340 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 331
Appendices Framing Status Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,unused,unused,unused,framing status, laser on position,laser off position,laser power,background color> 0 = Disabled 0 = Disabled 1 = Enabled
Laser On Position Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,unused,unused,unused,framing status, laser on position,laser off position,laser power,background color> 10 10 to 90
Laser Off Position Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,unused,unused,unused,framing status, laser on position,laser off position,laser power,background color> 95 15 to 95
Laser Power Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,unused,unused,unused,framing status, laser on position,laser off position,laser power,background color> 1 = Medium 0 = Low 1 = Medium 2 = High
Background Color Serial Cmd: Default: Options:
<K253,index,gain,AGC mode,tracking,unused,unused,unused,framing status, laser on position,laser off position,laser power,background color> 0 = White 0 = White 1 = Black
Switch Timing Switch Mode Serial Cmd: Default: Options:
<K254,switch mode,time> 0 = Time 0 = Time
Time Serial Cmd: Default: Options:
<K254,switch mode,time> 10 (100 ms) 1 to 65535 (in 10 ms increments)
QX-830 Compact Industrial Scanner User Manual
A-43
Page 332
Serial Commands
Symbologies Quiet Zone Background Color Symbol Ratios Composite AIAG Depth of Field Enhance Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MicroPDF417 Symbol Reconstruction
<K450,quiet zone status> <K451,background color> <K452,Code 39,Codabar,Interleaved 2 of 5> <K453,symbology status,separator status,separator> <K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4, ID5a,ID5b,ID5c,status5, ID6,status6,ID7,status7,ID8, status8, ID9,status9,ID10,status10,ID11,status11,ID12,status12> <K456,DOF Enhance mode> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar,range mode status> <K473,mode,EAN status,supplementals status,separator status, separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, application record separator character,application record brackets, application record padding,separation factor> <K475,mode,fixed symbol length status,symbol length> <K476,status,scan line limit,fixed symbol length status,fixed symbol length,decode at end of read cycle> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,scan line limit,fixed symbol length status,fixed symbol length> <K496,symbol reconstruction redundancy,symbol reconstruction effort>
Quiet Zone Serial Cmd: Default: Options:
A-44
<K450,quiet zone status> 3 = Narrow, Enhanced 0 = Standard 1 = Narrow 2 = Standard, Enhanced 3 = Narrow, Enhanced
QX-830 Compact Industrial Scanner User Manual
Page 333
Appendices
Background Color Serial Cmd: Default: Options:
<K451,background color> 0 = White 1 = Black
Symbol Ratios Code 39 Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Codabar Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Interleaved 2 of 5 Serial Cmd: Default: Options:
<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive
Composite Symbology Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
A-45
Page 334
Serial Commands Separator (Composite) Serial Cmd: Default: Options:
<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character
AIAG Serial Cmd: Default: Options:
<K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4,ID5a,ID5b, ID5c,status5,ID6,status6,ID7,status7,ID8,status8,ID9, status9,ID10, status10, ID11,status11,ID12,status12> 0 = Disabled 0 = Disabled 1 = Enabled
Depth of Field Enhance Serial Cmd: Default: Options:
<K456,mode> 2 = Medium 0 = Disabled 1 = Low 2 = Medium 3 = High
Code 39 Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:
A-46
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
Page 335
Appendices Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 128
Full ASCII Set (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled
Codabar Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Start/Stop Match (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
A-47
Page 336
Serial Commands Start/Stop Output (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled
Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128
Check Character Type (Codabar) Serial Cmd: Default: Options:
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)
Check Character Output (Codabar) Serial Cmd: Default: Options: A-48
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled QX-830 Compact Industrial Scanner User Manual
Page 337
Appendices
Interleaved 2 of 5 Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128
Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128
Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled
Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:
<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual
A-49
Page 338
Serial Commands
UPC/EAN Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
EAN Status Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled
Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required
Separator Status (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Separator Character (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any 7-bit ASCII character
Supplemental Type (UPC/EAN) Serial Cmd: Default: Options:
A-50
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Both 0 = Both 1 = 2 characters only 2 = 5 characters only
QX-830 Compact Industrial Scanner User Manual
Page 339
Appendices Format UPC-E as UPC-A (UPC/EAN) Serial Cmd: Default: Options:
<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled
Code 128/EAN 128 Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge
Fixed Symbol Length Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding, separation factor> 10 1 to 128
EAN 128 Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 1 = Enabled 0 = Disabled 1 = Enabled 2 = Required
QX-830 Compact Industrial Scanner User Manual
A-51
Page 340
Serial Commands Output Format (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Standard 0 = Standard 1 = Application
Application Record Separator Status (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Separator Character (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> , (comma) Any 7-bit ASCII character
Application Record Brackets (Code 128/EAN 128) Serial Cmd:
Default: Options:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
Application Record Padding (Code 128/EAN 128) Serial Cmd:
Default: Options:
A-52
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding,separation factor> 0 = Disabled 0 = Disabled 1 = Enabled
QX-830 Compact Industrial Scanner User Manual