The text of a manual · part 37 of 43
QX-830 Compact Industrial Scanner User Manual, pages 361 to 370
Pages 361 to 370 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 361
Appendices
Laser Current Warning Message High Current Status Serial Cmd: Default: Options:
<K411,high current status,high current message,low current status,low current message> 0 = Disabled 0 = Disabled 1 = Message
High Current Message Serial Cmd: Default: Options:
<K411,high current status,high current message,low current status,low current message> HIGH_LASER Any valid ASCII string up to 128 characters
Low Current Status Serial Cmd: Default: Options:
<K411,high current status,high current message,low current status,low current message> 0 = Disabled 0 = Disabled 1 = Message
Low Current Message Serial Cmd: Default: Options:
<K411,high current status,high current message,low current status,low current message> LOW_LASER Any valid ASCII string up to 128 characters
User-Defined Name Serial Cmd: Default: Options:
<K412,user-defined name> QX-830 Any valid ASCII string up to 50 characters
QX-830 Compact Industrial Scanner User Manual
A-73
Page 362
Serial Commands
Output Format Format Extract Format Insert Format Assign Output Format Status Output Filter Configuration Output Filter Enable
<K740,output index,start location,length> <K741,output index,length,hex string> <K742,symbol number,status> <K743,output format status> <K744,filter number,symbology,length,wildcard,placeholder, data,decode direction,database index> <K745,number of filters>
Format Extract Output Index Serial Cmd:
<K740,output index,start location,length>
Options:
1 to 100
Start Location Serial Cmd:
<K740,output index,start location,length>
Default:
0
Options:
1 to n (maximum number of characters in the symbol data).
Length Serial Cmd:
<K740,output index,start location,length>
Default:
0 (Disabled; end of format cell array)
Options:
1 to n (maximum number of characters in the symbol data).
Format Insert Output Index Output Index refers to the database entry to be modified with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output. Starting with index # 1, enter either an extract or insert command to begin building the required output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until the string is complete. Serial Cmd: <K741,output index,length,hex string> Options:
A-74
1 to 100
QX-830 Compact Industrial Scanner User Manual
Page 363
Appendices Length Specifies the length of the user-defined character string that will be inserted. This function is limited to 4 characters per output index, so multiple indexes must be entered in order to insert longer character sequences. For example, to insert a 10-character sequence in user-defined output, three commands with consecutive index numbers would be required, where the first two character sequence lengths were 4 and the third was 2. Serial Cmd: <K741,output index,length,hex string> Default:
0 (Disabled; end of format cell array)
Options:
1 to 4
Hex String Specifies a character string that represents ASCII characters to be inserted in the database entry. Two hex characters are required for every ASCII character to be inserted in the user-defined output string. These two characters comprise the hex (base 16) value of the ASCII character. For example, to enter the three-character sequence “Hi!”, 3 would indicate the length of the string, and a hex sequence of 486921 would be the ASCII sequence to be inserted. (48 = H; 69 = i; 21 = !) Important: Each pair of hex characters represents one ASCII character. Hex character pairs range from 00 to FF. Since there is a limit of 4 ASCII characters per insertion per database entry, there is a limit of 8 hex characters per insertion per database entry. Serial Cmd: <K741,output index,length,hex string> Default:
NULL (0x00)
Options:
00 to FF (As many as 4 bytes, or hex pairs.)
Format Assign Symbol Number Serial Cmd: <K742,symbol number,status> Options:
1 to 10 1 = Formatted output status for symbol # 1. 2 = Formatted output status for symbol # 2. ... ... 10 = Formatted output status for symbol # 10.
Status Serial Cmd: <K742,symbol number,status> Default:
0 = Disabled
Options:
0 = Disabled 1 = Enabled (Assign parameters to specified symbol.)
QX-830 Compact Industrial Scanner User Manual
A-75
Page 364
Serial Commands
Output Format Status Serial Cmd: <K743,output format status> Default:
0 = Disabled
Options:
0 = Disabled 1 = Enabled
Output Filter Configuration Filter Number Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Options:
1 to 10
Symbology Type Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0
Options:
0 = Any type 1 = Interleaved 2 of 5 2 = Code 39 3 = Code 128 4 = Codabar 5 = UPC 6 = PDF417 7 = EAN 128 8 = Code 93 9 = Pharmacode 10 = GS1 DataBar (RSS) 11 = MicroPDF417 12 = Composite
Length Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0
Options:
0 to 128
Wildcard Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
* = (0x2A)
Options:
Any ASCII input in the form of a pair of hex characters
A-76
QX-830 Compact Industrial Scanner User Manual
Page 365
Appendices Placeholder Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
? = (0x3F)
Options:
Any ASCII input in the form of a pair of hex characters
Data Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
NULL (0x00)
Options:
Any ASCII input in the form of a pair of hex characters
Decode Direction Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0 = Any Direction
Options:
0 = Any Direction 1 = Forward 2 = Reverse
Database Index Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, decode direction,database index> Default:
0 (any index)
Options:
0 to 10
Output Filter Enable Serial Cmd: <K745,number of filters> Default:
0
Options:
0 to 10
QX-830 Compact Industrial Scanner User Manual
A-77
Page 366
Serial Commands
Serial Utility Commands Type
Read Rate
Counters
Device Control
Master Database
Part Number / Checksum
Command <C> <Cp> <J> <a1> <N> <O> <T> <U> <V> <W> <X> <Y> <L1> <L2> <L3> <I> <H> <G> <Gn> <NEWM> <#> <#a> <#b> <#f> <!> <!a> <!b> <!f> <Z> <Zc> <Zrc>
Default/Reset/Save
<Zrd> <Zrdall> <A> <Arp>
A-78
Name Enter Decodes/Second Test Enter Decode Percent Test Exit Decodes/Second and Decode Percent Tests PDF417 Information No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Programmable Output 1 Programmable Output 2 Programmable Output 3 Disable Scanner Enable Scanner Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display FPGA Code Part Number Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display FPGA Code Checksum Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On Recall Customer Default Settings and Save for Power-On Recall Microscan Default Settings and Save for Power-On (Will not default “sticky settings”) Recall Microscan Default Settings and Save for Power-On (Will also default “sticky settings”) Reset (Will not save for power-on) Reset and Recall Power-On Parameters QX-830 Compact Industrial Scanner User Manual
Page 367
Appendices Default/Reset/Save
Scanner Status Request Commands
Other Serial Utility Commands
<Arc> <Ard> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <Knnnd> <@CAL> <@> <BCCFG>
QX-830 Compact Industrial Scanner User Manual
Reset and Recall Customer Default Parameters Reset and Recall Microscan Default Parameters All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Default Customer Parameter Calibrate without Menu Calibrate with Menu Enter Bar Code Configuration
A-79
Page 368
Protocol Commands
Appendix F, Protocol Commands Communication Protocol Command Table Protocol Command (Mnemonic displayed on menu)
Control Characters (Entered in menu or serial command)
Hex Value
Effect of Command
RES
^D
04
Reset
REQ
^E
05
Request
EOT
^D
04
Reset
STX
^B
02
Start of Text
ETX
^C
03
End of Text
ACK
^F
06
Acknowledge
NAK
^U
15
Negative Acknowledge
XON
^Q
11
Begin Transmission
XOFF
^S
13
Stop Transmission
A-80
QX-830 Compact Industrial Scanner User Manual
Page 369
Appendices
ACK/NAK Data Flow Examples Setup 1 RES REQ STX ETX ACK NAK LRC
0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 disabled
Transfer 1 HOST_TX SCANNER_TX
<K141,0> ‘ACK’
Transfer 2 HOST_TX SCANNER_TX SCANNER_TX HOST_TX
<K141?> ‘ACK’ <K141,0> ‘ACK’
Error Condition Transfer 1 SCANNER_TX HOST_TX SCANNER_TX HOST_TX symbol data ‘NAK’ (host rejects) symbol data (resend data) ‘ACK’ (transaction complete)
Transfer 2 HOST_TX <K141?> SCANNER_TX ‘ACK’ SCANNER_TX <K141,0> timeout reached... timeout reached... timeout reached... Timeout Reached transaction aborted, data is flushed
QX-830 Compact Industrial Scanner User Manual
A-81
Page 370
Protocol Commands
Setup 2 RES REQ STX ETX ACK NAK LRC
0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x00 (disabled) 0x06 0x15 enabled
Transfer 1 HOST_TX SCANNER_TX
<K141,0>a ‘ACK’
Transfer 2 HOST_TX SCANNER_TX SCANNER_TX HOST_TX
<K141?>B ‘ACK’ <K141,0>a ‘ACK’
Error Condition Transfer 1 HOST_TX SCANNER_TX HOST_TX SCANNER_TX
A-82
<k141,0>x (BAD LRC) ‘NAK’ <K141,0>a (GOOD LRC) ‘ACK’
QX-830 Compact Industrial Scanner User Manual