Page 181
Scanner Parameters
Static Presentation Static Presentation Mode is used in conjunction with Continuous Read mode. When operating in Static Presentation Mode, the red LEDs will illuminate while the scanner is searching for a symbol in Continuous Read mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the scanner is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
QX-830 Compact Industrial Scanner User Manual
5-115
Page 182
I/O Parameters
Green Flash Duration Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value.
Beeper An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. Note: The beeper will also sound at any of the following times: • When the scanner is defaulted. • When a Send and Save command is sent from ESP. • At the conclusion of an Auto Calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent from ESP’s Terminal.
5-116
QX-830 Compact Industrial Scanner User Manual
Page 183
Scanner Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the scanner will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. Host Scanner If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Command Beep Status Used to audibly verify the acceptance and validity of a command. Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
QX-830 Compact Industrial Scanner User Manual
5-117
Page 184
I/O Parameters
Control / Hex Output Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M.
5-118
QX-830 Compact Industrial Scanner User Manual
Page 185
Scanner Parameters
EZ Button
Serves as a master switch to enable/disable the EZ Button status.
The EZ Button has four positions: Single Beep, Two Beeps, Three Beeps, and Four Beeps, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight EZ Button Modes.
QX-830 Compact Industrial Scanner User Manual
5-119
Page 186
I/O Parameters
EZ Button Status
Disabled When set to Disabled, the EZ Button does not function.
Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Modes command.
Trigger When selected, the EZ Button acts as a trigger for the scanner to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:
The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and End of Read Cycle Mode is set to Timeout. As with External Level, External Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike External Level, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.
Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.
Default on Power-On When enabled, if the EZ Button is held down on power-on, the scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command from ESP’s Terminal.
5-120
QX-830 Compact Industrial Scanner User Manual
Page 187
Scanner Parameters
EZ Button Modes Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 8 modes.
Single Beep Hold down button until a single beep is heard (and the 20% LED illuminates).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
QX-830 Compact Industrial Scanner User Manual
5-121
Page 188
I/O Parameters
Two Beeps Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate.)
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To cancel Bar Code Configuration, quickly press and release the EZ Button.
5-122
QX-830 Compact Industrial Scanner User Manual
Page 189
Scanner Parameters
Three Beeps Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs illuminate).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
QX-830 Compact Industrial Scanner User Manual
5-123
Page 190
I/O Parameters
Four Beeps Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80% LEDs illuminate).
Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
5-124