Page 191

Scanner Parameters

Auto Framing Options When Enabled, Laser Framing is performed when the Auto Framing button beep position is selected (Single Beep, Two Beeps, Three Beeps, or Four Beeps).

QX-830 Compact Industrial Scanner User Manual

5-125

Page 192

I/O Parameters

Status Indicators The side of the QX-830 features an array of LEDs that indicate various aspects of scanner activity.

Controls the operation of the MOD/ACT and NET/LNK LEDs. Note: MOD and ACT function as one combined LED, as do NET and LNK.

Disabled When set to Disabled, the MOD/ACT and NET/LNK LEDs are always off. Note: All green and red LEDs will turn on briefly during power-on or reset to confirm that they are functioning.

PHY Activity If Ethernet is available: LNK = Solid green when transceiver is linked. ACT = Blinking green when transceiver detects Tx or Rx activity. Otherwise, for all RS232 and RS422/485 activity: LNK = Blinking green with Tx data activity. ACT = Blinking green with Rx data activity. Note: Red is never turned on.

Protocol Activity If EtherNet/IP is enabled: MOD = Module status, per EtherNet/IP specification NET = Network status, per EtherNet/IP specification Otherwise, the MOD and NET LEDs are always off. 5-126

QX-830 Compact Industrial Scanner User Manual

Page 193

Scanner Parameters

Bar Graph Read Rate, Auto Calibration, Bar Code Configuration, and Read Cycle Result all share the Bar Graph (20% – 100%) LEDs.

I/O 1 I/O 1 always shows the combined state of the discrete outputs. If any output is active, the I/O 1 LED will be on.

I/O 2 I/O 2 always shows the state of the hardware input trigger. If the trigger is active, I/O 2 will be on.

QX-830 Compact Industrial Scanner User Manual

5-127

Page 194

I/O Parameters

Calibration Options Calibration Options specifies the operation of the calibration feature. The default configuration is set up to perform calibration on Gain, Focus and Symbol Type.

Video When set to Calibrate, there will be an attempt to change Video settings (Gain and Tracking). Video settings include Gain and Tracking.

Scan Speed When set to Calibrate, there will be an attempt to change Scan Speed. If a better read rate at a different speed is found, the new speed will be the calibration result for Scan Speed.

Laser Power When set to Calibrate, there will be an attempt to change Laser Power. If a better read rate at a higher power is found, or if the same read rate at a lower power is found, the new power level will be the calibration result for Laser Power.

5-128

QX-830 Compact Industrial Scanner User Manual

Page 195

Scanner Parameters

Laser Framing When set to Calibrate, there will be an attempt to frame the symbol automatically. Framing is based on symbol readability. The frame line will be decreased until a drop in read performance is detected. Once the line length is found then a small margin is added to account for variation.

Symbol Type When set to Calibrate, all supported symbologies (except PDF417 and Pharmacode) will be attempted during calibration. Symbol lengths are not detected. Any new symbologies successfully decoded during calibration will remain enabled at the end of the process. All enabled symbologies will remain enabled. For example, assume that only Code 39 is enabled at the beginning of calibration. If a Code 128 symbol is read during calibration, then Code 128 as well as Code 39 will be enabled at the end of calibration.

QX-830 Compact Industrial Scanner User Manual

5-129

Page 196

I/O Parameters

Database Identifier Output Useful in tracking which database entries read which symbols.

Database Identifier Output Status

Disabled When this command is disabled, no database identifier information will be output.

Enabled When this command is enabled, the scanner will append a two-digit number and the characters “DB” to the data output following the separator for each symbol decoded using Configuration Database. For example, if the separator is an underscore character and the second database entry reads a symbol encoded with “data capture” during the read cycle, the symbol data output will be “data capture_DB02”. If the database is not active, no identifiers will be attached to output.

Separator Character The separator character separates the symbol data from the database identifier.

5-130

QX-830 Compact Industrial Scanner User Manual

Page 197

Scanner Parameters

Input 1

Input Mode Determines the function of the Input pin.

Disabled When set to Disabled, the Input pin has no impact on operation.

Reset Counts When set to Reset Counts, a transition to the active state of the Input will cause the scanner to reset the internal counters.

Unlatch Output This setting is used in combination with any of the three outputs in Latch Mode 1 (Unlatch Input # 1 Pin). A transition to the active state will clear any of the three outputs that were previously latched.

Active State

Active Open Input function is activated when input state is de-energized.

Active Closed Input function is activated when input state is energized.

QX-830 Compact Industrial Scanner User Manual

5-131

Page 198

I/O Parameters

Output 1 Parameters Output On Output On provides discrete signalling to host software to control external devices such as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and mis-routing. Sets the discrete output functions for specific user-selected conditions. Allows the user to set the conditions under which an output (or outputs) will be activated. Note: If Output On is set to Match or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master symbol is loaded into memory.

Mismatch or No Read Activates discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.

Good Read / Match Activates a discrete output when the symbol data matches the master symbol. Note: To output on Good Read when Matchcode is not enabled, enable any output for Match.

Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.

No Read Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.

5-132

QX-830 Compact Industrial Scanner User Manual

Page 199

Scanner Parameters

Trend Analysis Typically used when successful decodes are occurring but a discrete output is needed to flag a trend in quality issues. Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.

Diagnostic Warning Typically used when a discrete indication of a diagnostic condition is needed. Activates discrete output when a diagnostic warning condition is met, depending on the diagnostic option enabled.

In Read Cycle Activates a discrete output when the scanner is in a read cycle.

QX-830 Compact Industrial Scanner User Manual

5-133

Page 200

I/O Parameters

Output State Sets the active electrical state of the discrete output.

Pulse Width Sets the time in 10 ms increments that the discrete output remains active.

5-134

QX-830 Compact Industrial Scanner User Manual