Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 43

QX-830 Compact Industrial Scanner User Manual, pages 171 to 180

Pages 171 to 180 of 422

The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan QX-830

Page 171

Scanner Parameters

Symbol Ratio Mode Symbol Ratio Mode is useful for determining how much quality and data security validation will be applied when decoding a Code 39, Codabar, or Interleaved 2 of 5 symbol. Tight ratios will only decode a high-quality symbol. Standard ratios will decode most symbols. Aggressive ratios will not validate the entire symbol before decoding. The ratios are “loosened” to read poor-quality symbols. This setting is not recommended unless users understand the potential ramifications: character substitution rate may increase dramatically when Symbol Ratio Mode is set to Aggressive.

Code 39

Tight Maximum ratio is set to 3.6:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security. A Validate Bars function minimizes the acceptance of skewed symbols.

Standard Maximum ratio is set to 4.0:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security.

Aggressive Maximum ratio is set at 5.5:1. A Validate function is not used in this mode. This method may be useful on long symbols where the spot velocity can change throughout the symbol and effect the minimum and maximum bar values.

QX-830 Compact Industrial Scanner User Manual

5-105

Page 172

Symbologies

Codabar

Tight Maximum ratio is set to 3.6:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security. A Validate Bars function minimizes the acceptance of skewed symbols.

Standard Maximum ratio is set to 4.0:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security.

Aggressive Maximum ratio is set at 5.8:1. A Validate function is not used in this mode. This method may be useful on long symbols where the spot velocity can change throughout the symbol and effect the minimum and maximum bar values.

Interleaved 2 of 5

Tight Maximum ratio is set to 3.6:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security. A Validate Bars function minimizes the acceptance of skewed symbols.

Standard Maximum ratio is set to 4.8:1. A Validate function, which compares the ratio between the maximum and minimum bars in the symbol, is used for additional security.

Aggressive Maximum ratio is set at 6.1:1. A Validate function is not used in this mode. This method may be useful on long symbols where the spot velocity can change throughout the symbol and effect the minimum and maximum bar values.

5-106

QX-830 Compact Industrial Scanner User Manual

Page 173

Scanner Parameters

I/O Parameters Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the I/O tab to display the I/O Parameters tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: I/O Parameters settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the I/O Parameters section of Appendix E. QX-830 Compact Industrial Scanner User Manual

5-107

Page 174

I/O Parameters

Symbol Data Output Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Symbol Data Output Status Disabled It is useful when an application only needs to use the discrete outputs and can allow the scanner to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the scanner will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)

Match Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the scanner transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A No Read can still be transmitted if Enabled.

Mismatch Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the scanner transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A No Read can still be transmitted if Enabled.

Good Read Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the scanner transmits symbol data on any good read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if Enabled.

5-108

QX-830 Compact Industrial Scanner User Manual

Page 175

Scanner Parameters

When to Output Symbol Data This command allows the user to choose when symbol data can be sent to the host.

As Soon As Possible As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded.

End of Read Cycle End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time that it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle

Start of read cycle Read cycle duration Host activates trigger

QX-830 Compact Industrial Scanner User Manual

This is when host expects output

5-109

Page 176

I/O Parameters

No Read Message Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.

No Read Message Status Disabled Only symbol data is output after a read cycle.

Enabled When the scanner is in a triggered mode, a No Read message will be appended for each failed read attempt.

Message Any combination of ASCII characters can be defined as the No Read message. Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character.

5-110

QX-830 Compact Industrial Scanner User Manual

Page 177

Scanner Parameters

Bad Symbol Message Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if a qualified symbol is present but not decodable. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. Note: When Symbology Identifier is enabled, the Bad Symbol Message is preceded by the identifier for the symbology being used.

Message Any combination of ASCII characters can be defined as the Bad Symbol Message.

QX-830 Compact Industrial Scanner User Manual

5-111

Page 178

I/O Parameters

No Symbol Message Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if an object does not qualify as a symbol. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. Note: When Symbology Identifier is enabled, the No Symbol Message is preceded by the identifier for the symbology being used.

Message Any combination of ASCII characters can be defined as the No Symbol Message.

5-112

QX-830 Compact Industrial Scanner User Manual

Page 179

Scanner Parameters

Read Duration Output Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output. Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.

Separator User-defined character that separates the symbol information from the Read Duration Output.

QX-830 Compact Industrial Scanner User Manual

5-113

Page 180

I/O Parameters

Output Indicators

The QX-830 has a beeper and two LED arrays, as follows: 1. An array of green LEDs projected from the front of the scanner that can be programmed to flash in response to user-defined conditions. 2. An array of status LEDs on the side of the scanner.

Green Flash Mode

Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the scanner can be programmed to flash in response to user-defined conditions.

Disabled Green flash LEDs are disabled.

On Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.

5-114

QX-830 Compact Industrial Scanner User Manual