Page 161

Scanner Parameters

Composite When set to Enabled or Required, will decode the 2D composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E.

Enabled If Composite is set to Enabled, the scanner will decode both the 2D composite and linear components. However, if the 2D composite component is not decoded, the linear data will be sent by itself at the end of the read cycle.

Required If set to Required, the scanner must decode both components, or a No Read will occur.

Separator Status Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component.

Separator The Separator Character will be the same as the character defined in the Multisymbol Separator field. As required by the application. Allows the user to change the separator character from a comma to a new character.

QX-830 Compact Industrial Scanner User Manual

5-95

Page 162

Symbologies

AIAG AIAG is a standard controlled by the Automotive Industry Action Group. AIAG is used in automotive applications. When AIAG is Enabled, each Status field can be Enabled or Disabled, and an ID can be defined for each status.

5-96

QX-830 Compact Industrial Scanner User Manual

Page 163

Scanner Parameters

Quiet Zone Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. Allows the scanner to read 1D symbols with quiet zones less than 8 times the width of the narrow bar element. The Quiet Zone is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Quiet Zone is Enabled and set to Narrow or Narrow, Enhanced.

Note: Do not use Narrow or Narrow, Enhanced when Large Intercharacter Gap is enabled for Code 39. Note: Any Quiet Zone setting other than Standard will increase processing requirements.

Standard The scanner locates symbols using a standard 8x Quiet Zone requirement.

Narrow The scanner locates symbols using a 5x Quiet Zone requirement.

Standard, Enhanced The scanner locates symbols using an enhanced algorithm for standard 8x Quiet Zones. The enhanced algorithm has a higher tolerance for leading-edge “noise”, and is particularly useful for high density symbols.

Narrow, Enhanced The scanner locates symbols using an enhanced algorithm for 5x Quiet Zones. The enhanced algorithm has a higher tolerance for leading-edge “noise”, and is particularly useful for high density symbols. This setting is the Default because it overcomes many symbol quality issues, such as printing and placement inconsistencies.

QX-830 Compact Industrial Scanner User Manual

5-97

Page 164

Symbologies

Symbology Identifier Symbology Identifier is a standard prefix set of characters that identifies the symbol type. When enabled, the scanner analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, L, e, or p • (A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code 93; I = Interleaved 2 of 5; L = PDF417 and MicroPDF417; e = GS1 DataBar (RSS); p = Pharmacode) • Modifier Example: ]C indicates a Code 128 symbol.

Disabled When set to Disabled, symbol data output does not contain Symbology Identifier information.

Enabled AIM ID When set to Enabled AIM ID, symbol data output contains a three-character AIM Symbology Identifier sequence.

Enabled Readable ID When set to Enabled Readable ID, symbol data output contains a human-readable description of the decoded symbology. Examples: ]CODE39 ]CODE128 ]UPCA ]UPCEAN13

5-98

QX-830 Compact Industrial Scanner User Manual

Page 165

Scanner Parameters

Explanation of Modifiers for Code 39, Codabar, and Interleaved 2 of 5 • For Code 39, Codabar, and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier

Check Character

0 1 3 4 5 7

Disabled Enabled Enabled Disabled Enabled Enabled

Check Character Output N/A Enabled Disabled N/A Enabled Disabled

Full ASCII Conversion (Code 39 Only) No No No Yes Yes Yes

Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.

Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates EAN 128; otherwise the modifier is 0. • For all other symbologies, the modifier is 0.

QX-830 Compact Industrial Scanner User Manual

5-99

Page 166

Symbologies

Background Color Symbol backgrounds are often White, or other very light colors. If the background is darker than the symbol, Black background should be enabled. Allows the user to specify the symbol background used in the application.

White When White background is enabled, the bars of linear symbols and the elements of 2D symbols are recognized as dark on a light background.

Black When Black background is enabled, the bars of linear symbols and the elements of 2D symbols are recognized as light on a dark background.

5-100

QX-830 Compact Industrial Scanner User Manual

Page 167

Scanner Parameters

Depth of Field Enhance The Default Depth of Field Enhance setting of Medium will be ideal for 75% of all depth of field issues. Low and High account for the other 25%. Note: Any setting other than Disabled will increase processing requirements.

Disabled No extra processing of elements is performed to extend depth of field.

Low Minimal additional processing of elements is performed to extend depth of field. The Low setting is not recommended for most applications that require Depth of Field Enhance. However, some focus and printing issues may make this the optimal setting.

Medium Some additional processing of elements is performed to extend depth of field. The Medium setting is the most likely to be useful in applications that require Depth of Field Enhance.

High Additional processing of elements is performed to extend depth of field. The High setting is not recommended for most applications that require Depth of Field Enhance. However, some focus and printing issues may make this the optimal setting.

QX-830 Compact Industrial Scanner User Manual

5-101

Page 168

Symbologies

Symbol Reconstruction Industrial environments present many data capture challenges, some of which are damaged symbols, partially covered symbols, poorly printed symbols, and variation of label placement. Symbol quality, location, and orientation cannot always be controlled. Labels can be torn, partially obscured, overprinted, or underprinted due to variations in print mechanisms. For industrial tracking and traceability to be reliable, symbols must be decoded regardless of damage, label tilt, or any other discontinuities. The QX-830 features X-Mode™ technology, which allows the scanner to reconstruct data from damaged or poorly positioned symbols by “stepping though” the elements (bars) in multiple stages and then combining the successfully decoded regions into completed symbol data output, as shown in the simplified example below. Note: Symbol Reconstruction functions with Code 39, Code 128, Interleaved 2 of 5, and UPC/EAN symbols.

5-102

QX-830 Compact Industrial Scanner User Manual

Page 169

Scanner Parameters

Symbol Reconstruction Redundancy

Disabled When Symbol Reconstruction Redundancy is Disabled, the scanner will not attempt to reconstruct symbols across multiple scan lines.

Low When Symbol Reconstruction Redundancy is set to Low, the scanner will attempt to reconstruct symbols across multiple scan lines. Only the minimum amount of redundancy checking will be applied to qualify the reconstruction result. This can limit the Effort level required to decode. However, this is the lowest level of proof required, so occasionally the symbol’s level of data integrity may lead to a misread. Note: Applications with low area coverage may be forced to use this setting.

Medium When Symbol Reconstruction Redundancy is set to Medium, the scanner will attempt to reconstruct symbols across multiple scan lines. A larger amount of redundancy checking will be applied to qualify the reconstruction result. This may require the decode Effort level to be increased. This level of redundancy checking is helpful in avoiding misreads. Occasionally the symbol’s level of data integrity may lead to a misread, but this setting requires enough matching data to protect the majority of data. Note: Applications with average area coverage can use this setting.

High When Symbol Reconstruction Redundancy is set to High, the scanner will attempt to reconstruct symbols across multiple scan lines. A very large amount of redundancy checking will be applied to qualify the reconstruction result. This will require the effort level to rise to achieve a decode. This level of redundancy checking is helpful in avoiding misreads. Occasionally the symbol’s level of data integrity may lead to a misread, but this setting requires enough matching data to protect the majority of data. Note: Applications with a large amount of area coverage can use this setting. However, as aspect ratio decreases and line speed increases, High may not provide enough decodes to be useful. The Effort level may also require more time in some cases.

QX-830 Compact Industrial Scanner User Manual

5-103

Page 170

Symbologies

Symbol Reconstruction Effort

Minimum When Symbol Reconstruction Effort is set to Minimum, the scanner will attempt to reconstruct symbols across multiple scan lines. However, the required processing time will be limited to a minimum level, so candidate symbols that are not valid will be rejected quickly.

Moderate When Symbol Reconstruction Effort is set to Moderate, the scanner will attempt to reconstruct symbols across multiple scan lines. The required processing time will be limited to a level that is expected to work optimally for most applications. Moderate is the appropriate setting for most symbol reconstruction scenarios. Moderate can still reject candidate symbols, but there may be a noticeable pause in throughput. Usually, candidate symbols will either decode or self-eliminate before the effort level is reached.

Maximum When Symbol Reconstruction Effort is set to Maximum, the scanner will attempt to reconstruct symbols across multiple scan lines. However, if a large amount of processing is required, reconstruction is allowed to attempt all decode possibilities. This Effort level may cause the system to stall on the present data as it attempts to decode all possibilities.

5-104

QX-830 Compact Industrial Scanner User Manual