Page 51

4 Communications Contents Communications by ESP.............................................................................................................. 4-2 Communications Overview........................................................................................................... 4-3 USB Interface ............................................................................................................................... 4-4 PS/2 Interface............................................................................................................................... 4-5 RS-232 Interface .......................................................................................................................... 4-6 Bluetooth Interface ....................................................................................................................... 4-8 Batch/Battery .............................................................................................................................. 4-16 Preamble .................................................................................................................................... 4-20 Postamble................................................................................................................................... 4-21 Preamble and Postamble by ESP .............................................................................................. 4-22 Keyboard Mapping .................................................................................................................... 4-23 Text Commands ......................................................................................................................... 4-24 Time Stamp ................................................................................................................................ 4-25 Other Communications Settings in ESP..................................................................................... 4-26

This section includes connection parameters and options for communicating with the MS-Q Imager in various interfaces.

MS-Q Imager User’s Manual

4-1

Page 52

Communications by ESP

Communications by ESP To make changes to configuration settings in the Communications tree control:

1. Left click on the + to expand the tree.

2. Double click on the parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change and click once on the setting.

4-2

4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the imager.

MS-Q Imager User’s Manual

Page 53

Communications

Communications Overview All MS-Q Imagers are shipped with a USB or PS/2 cable. You can also add RS-232 and Bluetooth capabilities and configure your imager accordingly. Whenever you default the imager, it will return to the default settings of whichever interface you are using. Defaulting the imager does not remove preamble and postamble formatting. Note: You must use USB Connect Mode or RS-232 Connect Mode to connect to ESP. Once the imager is connected to ESP, you can select your communications mode and set other communication parameters.

USB With USB communications, the imager connects directly to the host’s USB port from which it draws its power. Data is displayed by any open Windows-based program that can capture text in USB Keyboard Mode.

PS/2 With PS/2 communications, the imager connects directly to the host’s keyboard port from which it draws its power. Data is displayed by any open Windows-based program that can capture text in PS/2 Keyboard Mode.

RS-232 With RS-232 communications the imager communicates with the host through a communications program such as HyperTerminal. Default settings for establishing RS-232 communications are: Baud = Parity = Stop Bits = Data Bits = Flow Control =

57.6K None Two Eight None

Bluetooth The Bluetooth version of the imager includes an internal Bluetooth wireless radio. The radio allows for point-to-point wireless communication with other Bluetooth devices that support serial port protocol (SPP).

Batch/Battery The MS-Q’s Batch Mode is intended for applications that require a portable reader. Scanned data is saved to the imager’s non-volatile memory, and can then be transferred to a host. MS-Q Imager User’s Manual

4-3

Page 54

USB Interface

USB Interface USB Keyboard is the default interface in which data is transferred to a Windows-based text program as keyboard data. See USB Interface on page 1-6 for detailed steps on setting up the USB Interface.

USB Keyboard Mode Data is entered as keyboard sequences. You need to read this symbol whenever you are changing from a different interface to USB.

USB Downloader Mode This mode is the standard way of transferring unformatted, unpacketized data to the imager through the USB port.

USB Native Two-Way Mode This mode is used when the user needs error-corrected communication between the MS-Q and the host the USB port.

USB Virtual COM Mode This mode allows an MS-Q in a USB configuration to function as a virtual serial COM port. This mode requires installation of a USB Virtual COM driver. Contact your Microscan sales representative to request this driver, as well as installation instructions.

Save Settings

4-4

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 55

Communications

PS/2 Interface PS/2 Keyboard is the default interface in which data is transferred to a Windows-based text program as keyboard data. See PS/2 Interface on page 1-7 for detailed steps on setting up the PS/2 interface.

PS/2 Keyboard Mode Data is entered as keyboard sequences. Read this symbol whenever you are changing from a different interface to PS/2. Important: The imager must be connected to the keyboard for the imager and the keyboard to function in PS/2 Keyboard Mode.

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

4-5

Page 56

RS-232 Interface

RS-232 Interface Enabling either of these modes will disable USB or PS/2 communications and require you to default the imager or read the “USB Keyboard” symbol to return to USB. See RS-232 Interface on page 1-8 for detailed steps on setting up the RS-232 Interface.

RS-232 Default Settings Mode This mode is the standard way of transferring unformatted, unpacketized data through the RS-232 port.

You will need to read this symbol whenever you set up RS-232 communications.

Baud Rate (RS-232) Baud Rate is the rate at which the imager and host transfer data. It only needs to be changed if necessary to match the host setting.

1200

19.2K

2400

38.4K

4800

57.6K (Default)

9600

115.2K

Save Settings

4-6

Default to USB

Default to PS/2

Save Settings

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 57

Communications

Parity (RS-232) Parity is an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. It only needs to be changed if necessary to match the host setting.

None (Default)

Even

Odd

Stop Bits (RS-232) Stop Bits are added to indicate the end of each character. This setting should only be changed if necessary to match the host setting.

2 Stop Bits (Default)

1 Stop Bit

Data Bits (RS-232) Data Bits are the total number of bits in each character. This setting only needs to be changed if necessary to match the host setting.

8 Data Bits (Default)

7 Data Bits

Timeout Settings (Cabled) This feature sets the amount of time a cabled MS-Q will be enumerated before entering Sleep Mode in order to charge the battery more quickly.

Cabled Timeout Never (Default)

Save Settings

MS-Q Imager User’s Manual

Default to USB

Cabled Timeout 2 Hours (Default)

Default to PS/2

Clear All Data

Clear XML Rules

4-7

Page 58

Bluetooth Interface

Bluetooth Interface USB For quick setup information about connecting to the Bluetooth modem via USB, see Bluetooth Interface on page 1-9.

RS-232 Once the imager is connected via RS-232, the software on the host must be open to receive data with a communications program such as HyperTerminal. Baud = Parity = Stop Bits = Data Bits = Flow Control =

57.6K None One Eight None

The Bluetooth radio is a Class 1 device. If connected to another Class 1 device the imager has roughly 100 meters (328 feet) line-of-sight operating range. If connected to a Class 2 or Class 3 device, the operating range may drop to match the lower range. When the imager detects that the radio is out of range, it will store data in non-volatile memory. The imager will continue to try to send data until the radio is back in range. Once the data is sent, it will be erased from the unit’s memory unless Batch Mode is set for Send and Log. If the radio cannot connect in 90 seconds, it will emit an error beep. The imager will continue to try to connect until it has reached the programmable radio timeout setting. If the imager is in RF Two-Way Mode and Auto-Connect is enabled (which it is by default), it will automatically attempt to reconnect with the host modem whenever: • The imager is powered-on. • The imager attempts to read another symbol. Another important thing to consider is Bluetooth access. You choose Private when you want to limit access to only one imager. You choose Shared when you want more than one imager to have continuous access.

4-8

MS-Q Imager User’s Manual

Page 59

Communications

Connecting to the Bluetooth Modem via RS-232 RF Two-Way is the mode used when communicating with the Bluetooth modem in RS-232. It is used when there is a need for bidirectional communication between the imager and an application by radio frequency (i.e. Time Stamp, Error Checking, Shared Access, etc.). The imager receives confirmation via packet protocol verification and is 100% reliable. To connect to the Bluetooth modem: 1. Read the RF Two-Way Mode symbol at right. 2. Read the Quick Connect Symbol located on the TOP of your connected Bluetooth modem to establish communications. 3. Read the Save Settings symbol.

RF Two-Way Mode

Bluetooth Communication Indicators Memory LED (LEFT indicator)

Bluetooth Activity Attempting to Connect to Bluetooth Bluetooth Connection Failed Bluetooth Connection Successful Sending Bluetooth Data

Battery LEDa (RIGHT indicator)

Sound

Flashes BLUE

Solid GREEN

None

None Flashes BLUE every 15 seconds Flashes Memory Status

None Flashes Battery Status every 15 seconds None

4 beeps None None a. When power is supplied via cable, the LED will remain green whenever the imager is active.

Disconnect You may force disconnection by reading the Disconnect symbol (in a Primary/Secondary Bluetooth connection, the imager may not appear disconnected for 10 to 15 seconds after the command is sent). The imager will also disconnect (go into Sleep Mode) after a period of inactivity (see Sleep Mode Timeout on page 4-12).

Disconnect

Auto-Connect After coming out of Sleep Mode or after powering-on, the imager tries to auto-connect with the last host modem it had been connected with. If Auto-Connect is enabled, the imager will connect to the host whenever it has data and the imager is idle (but not asleep). Auto-Connect (Default) This allows connected imagers to send data whenever it is read.

Disable Auto-Connect An imager that reads this symbol will not connect to the modem until re-programmed to do so.

Important: One-Way Mode is not supported by the Microscan Bluetooth modem. One-Way Mode is supported by most other Bluetooth modems (Belkin, for example). MS-Q Imager User’s Manual

4-9

Page 60

Bluetooth Interface

One-Way Mode Options One-Way Mode is only recommended when connecting to a device well within the imager’s specified range, or when connecting to a device without an operating system (a printer, for example). RF One-Way Mode (Maximum Range) This mode is the standard way of transferring unformatted, unpacketized data by radio frequency. The Maximum Range setting optimizes the imager for greater range but data reliability is lower. RF One-Way Mode (Maximum Reliability) The Maximum Reliability setting optimizes the imager for greater reliability but the radio range is lower.

Always read the Save Settings symbol after changing connectivity options.

Default RF

Save Settings

4-10

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual