Page 41

Using ESP

Default When you select Default Current Menu Settings or Default all ESP Settings you are only defaulting settings in ESP. The imager is not affected unless you download new settings.

Advanced Options Send Current View This is the same as Save to Reader > Send No Save except that only the commands in the current menu tree are sent.

Send Current Command This is the same as Send Current View above, but only saves the command that is currently selected.

MS-Q Imager User’s Manual

2-15

Page 42

Send/Receive

2-16

MS-Q Imager User’s Manual

Page 43

3 Basic Operations Contents Step 1 Practice Targeting ............................................................................................................. 3-2 Step 2 Determine Optimum Position ............................................................................................ 3-3 Step 3 Select Quadrus Only or Standard Mode ........................................................................... 3-4 Step 4 Select Adaptive or Fixed Mode ......................................................................................... 3-5 Step 5 Complete Configuration .................................................................................................... 3-6 Trigger and Button Programming ................................................................................................. 3-7 USB Battery Charge Mode ........................................................................................................... 3-8

This section explains how to practice targeting and triggering, how to begin configuring the imager, how to perform a hardware default, and how to switch between Quadrus Only and Standard modes. (Mode switching is available for MS-Q Quadrus models only.)

MS-Q Imager User’s Manual

3-1

Page 44

Practice Targeting

Step 1, Practice Targeting The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.

When first connecting, allow approximately 3 seconds for the imager to initialize. 1. Hold the imager steady and point at a symbol between 2.75 and 4.5 inches away (High Resolution Option) or between 2 inches and 19 inches away (Standard Resolution Option). 2. Squeeze and hold the trigger. 3. A red targeting spot will appear in front of the imager surrounded by a flashing RED LED pattern. 4. Center the laser spot on the symbol and wait a second or two for a decode. For configuration symbols, you will hear 2 beeps when a good read occurs. For data symbols, you will hear 1 beep when a good read occurs. 5. If no decode occurs, slowly draw away from the symbol while holding the laser spot steadily in place. Test Symbol ABCDEFGHIJKLMNOP

Targeting Suggestions • Typically, you should not hold the imager exactly perpendicular to the symbol. Position the imager about 15 to 30 degrees to avoid specular reflection. • Do not wave the imager side-to-side or up-and-down, or attempt to sweep across a symbol; sudden movements will create fuzzy images and result in failed read attempts. • The imager is omnidirectional and can read a symbol from any position (The exception to this is with certain linear symbols; in these cases, the read area will be oriented to the length of the symbol.)

Save Settings

3-2

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 45

Basic Operations

Step 2, Determine Optimum Position 1. Position the reader in front of the symbol. • High Resolution Option: 2.75 inches for near field or 4.5 inches for far field. • Standard Resolution Option: 4 inches for near field and 9 inches for far field. 2. Determine the optimum read position by triggering at different distances and angles. 3. To speed up decoding, try enabling near field or far field only. (Both fields are enabled by default.) In general, if the symbol element size is less than 0.010” (0.025 mm), enable near field to a focal point. If more than 0.010” (0.025 mm), try the far field focal point. Also, if symbols are placed closely together, you may want to use near field to lower the risk of reading the wrong symbol. See Trigger and Button Programming on page 3-7 for the configuration symbols that correspond to these settings. Other factors to consider: • Use Both Fields for applications in which symbols may vary significantly in size and distance from reader. • On Quadrus models, try Fixed Mode for even quicker decodes for symbols with consistent size and presentation (see Select Adaptive or Fixed Mode on page 3-5). • For a more advanced setup, see Trigger Optimization on page 7-7. Test Symbol ABCDEFGHIJKLMNOP

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

3-3

Page 46

Select Quadrus Only or Standard Mode

Step 3, Select Quadrus Only or Standard Mode This feature is available for MS-Q Quadrus models only. The firmware in the MS-Q Imager allows you to toggle easily between the specialized Quadrus Only Mode that is preferred for DPM (Direct Part Marking) or the more generalized Standard Mode. As with the MS-Q Basic, in its default configuration, the MS-Q Left Right Quadrus’s right button and handle Indicator Indicator also initiate reads; however, the left button is used to toggle between Quadrus Only and Standard Left Right Modes. Button Button When you press the left button while in Quadrus Only Mode, you will hear 3 beeps and see the left indicator LED flash RED 3 times. This indicates the imager has switched to Standard Mode. When you press the left button while in Standard Mode you will again hear 3 beeps, but now the left indicator LED flashes GREEN 3 times. This indicates the imager has returned to Quadrus Only Mode. Note: Reprogramming the left button disables mode shifting. Test Symbol ABCDEFGHIJKLMNOP

Save Settings

3-4

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 47

Basic Operations

Step 4, Select Adaptive or Fixed Mode This feature is available for MS-Q Quadrus models only. When you read symbols in the MS-Q default setup, the imager is in Adaptive Mode. In this mode, when the imager is activated by the handle trigger, it attempts to decode in both the near field and far field resolutions, checks for both light background or dark background images, and cycles through various gain values until a decode is achieved. It remains with those settings unless no decode occurs within ten attempts, in which case it resumes the adaptive routine. If your application involves relatively similar symbols at consistent ranges, you might speed up decode rates by switching the imager from Adaptive Mode to Fixed Mode. When you switch to Fixed, the optimum settings acquired in Adaptive will be locked in. This means that the imager will not have to search through the various settings to arrive at the optimum. However, the settings will be fixed to the distance, symbol background, etc. that were in effect when the last decode occurred in the Adaptive Mode.

Toggling Between Adaptive and Fixed To toggle between the Adaptive and Fixed Modes: 1. Find a position that gives you the best Left Indicator decodes. (See Determine Optimum Position on page 3-3.) Left 2. Press both the left and right top buttons at the same time and hold until you see both LED indicators (on top) flash RED twice. This indicates that the imager is now in Fixed Mode.

Right Indicator Right Button

Button

3. To return to Adaptive Mode, press both buttons again until the indicators flash GREEN twice, indicating that you have returned to Adaptive Mode. MS-Q settings can also be locked and unlocked by reading the following symbols:

MS-Q Settings Locked

Save Settings

MS-Q Imager User’s Manual

MS-Q Settings Unlocked

Default to USB

Default to PS/2

Test Symbol ABCDEFGHIJKLMNOP

Clear All Data

Clear XML Rules

3-5

Page 48

Complete Configuration

Step 5, Complete Configuration For the MS-Q Basic, in the default configuration, both the left and right buttons as well as the handle trigger can initiate reads. For the MS-Q Quadrus, in the default configuration, the right button and handle trigger also initiate reads; however, the left button is used to toggle between Quadrus Only and Standard Modes.

Left Indicator

Test Symbol

Right Indicator

ABCDEFGHIJKLMNOP Left Button

Save Settings

3-6

Default to USB

Right Button

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual

Page 49

Basic Operations

Trigger and Button Programming Trigger and button functionality can be configured to read just near field, just far field, or both fields using the symbols listed below. See also Trigger Optimization on page 7-7.

Handle Trigger Both Fields (Default)

Near Field Only

Far Field Only

Near Field Only

Far Field Only

Near Field Only

Far Field Only

Near Field Only

Far Field Only

Left Button Both Fields (Default)

Right Button Both Fields (Default)

Continuous Read Both Fields

Continuous Read Disabled (Default)

Save Settings

MS-Q Imager User’s Manual

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

3-7

Page 50

USB Battery Charge Mode

USB Battery Charge Mode If you choose to charge the MS-Q Imager’s battery with a USB connection, you have the option of using USB Battery Charge Mode. This mode dedicates most of the power available from the USB connection to charging the battery. Read the symbol below to enable this mode.

Default to Previous Settings (Disable USB Battery Charge Mode)

Enable USB Battery Charge Mode

Note: The imager is able to read and decode symbol data while in USB Battery Charge Mode. After each symbol decode the imager automatically returns to its battery charging state.

Save Settings

3-8

Default to USB

Default to PS/2

Clear All Data

Clear XML Rules

MS-Q Imager User’s Manual